ML20216B144

From kanterella
Jump to navigation Jump to search
Refers to 830421 Application.Confirms That J Glenn Will Review Application After Completion of Device Registration. Requests Addl Info Re Cobalt-60 Source,Extension of Six Month Leak Test Interval & Device Labels
ML20216B144
Person / Time
Site:
(NR-8003-S-821-S)
Issue date: 04/27/1983
From: Steven Baggett
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Minns D
ATOMIC ENERGY OF CANADA, LTD.
Shared Package
ML20216B022 List:
References
SSD, NUDOCS 9805150054
Download: ML20216B144 (2)


Text

/T (T

'IISTRIBUTION:

^

s

'/

FC Central File NMSS rf FCMC rf APR 2 71983 SLBaggett Atomic Energy of Canada ATTH: Mr. David Minns P.O. Box /C.P. 3504 Ottawa, Ont. klY 4G1 Gentlemen:

This refers to your application hand delivered on April 21, 1983. We understood that when the device registration is completed by the Material Certification and Procedures Branch, your license application will be reviewed by John Glenn, NRC, Region I.

To continue our device review, we need additional information and/or clarification of the items listed below:

o From your application, it appears that you plan to use Cobalt-60 and Cesium-137 in the scanner flask. We have information on the Cesium-137 sources. However, we need additional information on the Cobalt-60 source, i$e.,

maximum activity, manufacturer, model number and radiation dose measuring of a scinner flask containing the Cobalt-60.

o The NRC normally does not issue an extension of the six-month leak test interv'al.

In the event you wish to extend the interval to one year, you should provide information to demonstrate that the increase in time is justified by the performance characteristics of the device or a similar device.

o The NRC regulations require that your device be labeled in accordance with Section~20.203,10 CFR 20. To bring your labels into compliance with this regulation, you should add a trefoil simbol and the radioactive warning should read, " Caution Radioactive Material." The label must be durable enough to remain legible for the useful life of the device.

o Provide a diagram or description of how the slip brake works and the method of attachment of the guide cables and control cable to the flask.

o Provide the title and/or a, copy of the document that was used to obtain the stainless steel-depleted uranium e*(tectoid melting point of 800*F.

9805150054 930629 PDR RC SSD PDR eU PNME b DATE N gggfggFFICIAL RECORD COPY nne ronu us no so) nacu ono

u O

Atomic Energy of Canada APR 2 71983 1

For reasons of public health and safety, the NRC requires o

that all sources and devices be tested in accordance with the American National Standard Institute Criterion. Your device needs to be given an ANSI N538 (copy attached) designation. Since this is a custom device, you may use i

engineering analysis data or historical data to demonstrate-compliance with the requirements.

o We need dose rates at 5, 30, and 100 centimeters from the l

device. These measurements should be taken at the four major compass points. ' The points should he in both the longitudinal and transverse planes.

Provide a safety analyst.s iummary. Since this is a custom o

device, you may' include' pertinent facts about your radio-logical protection program. These facts can b.e used to reenforce any statements made.

I Upon receipt of this information, we will continue our custom device review.

j When the review has beencompleted, we will notify Mr. John Glenn (gegion I)

I to start the licensing review process.

If you have any questions, please contact me. My phone number is (301) 427-4240.

Sincerely, 0&%1 Si.,nsd By I

Skna L.B2ggett Steven L. Baggett

^

Material Certification and Procedures Branch l

Enclosure:

ANSI N538 cc:

J.' G1 enn, R:I J

J l

= = >..E.Qtc.. (.

-... ~ ~.

. ~ ~.. - -

'*ua"^"'> REO.99

,a d..................

................ ~.

4.l.21.lM......

. - -.. ~ ~.

gne ronu m oo..o> unc""

OFFICIAL RECORD COPY

f7 A

t** * %

0 Q) p f

g*

UNITED STATES

.l. W g

NUCLEAR REGULATORY COMMISSION

${

f WASHINGTON, D.C. 20555 0001 y' s

,/

JUL 0 61993 Mr. Joe Stirling Senior Licensing Coordinator j

Nordion International Inc.

j 447 March Road i

Kanata, Ontario, Canada K2K 1X8

Dear Mr. Stirling:

Based on the information and test data submitted in your application dated November 19, 1991, and subsequent letters, with enclosures thereto, we have transferred several registration certificates to " inactive" status and combined several other l

registration certificates as shown in Enclosure (1).

These sources and devices are acceptable for licensing purposes in accordance with the conditions of the enclosed registration l

certificates.

Please note, all registration certificates for Atomic Energy of Canada Limited have been assigned a vendor number of "8003".

Vendor number "0169" is no longer an active vendor number.

I Please be advised that you must manufacture and distribute the l

" active" products in accordance with the statements and representations contained in your application, with enclosures thereto, and the information set out in your registration certificates.

As a general rule, you must requist and obtain an amendment to each certificate before you make chagas or modifications to the information submitted to obtain the certificate.

Please read over the registration certificates in their entirety l

and notify us immediately of any errors or omissions.

You are l

obligated to notify us promptly in writing should you decide to no longer manufacture or offer service support for the products.

The registration certificates for the Models C-132, C-133, and i

C-265 have not been updated.

The following additional information is required in order to continue with this action:

l a) Please provide external radiation levels at 5 cm, 30 cm, and 100 cm from the surface of the C-265 source capsule when l

loaded with maximum activity.

i b) Please provide prototype testing for the C-132 source assembly.

You have stated that the C-132 source capsule is equivalent to the C-133 source capsule.

However, we do not have current prototype testing information for the C-132 and C-133 source capsules.

l Wit @~ 9 p f

D o

I Additionally, in order to update our files, please provide the additional information requested in my letter dated June 3, 1993.

I look forward to receiving the requested information as soon as possible.

If you have any questions, please contact me at (301) 504-2503 or Mr. John Lubinski at (301) 504-2689.

Sincerely,

,' 55 Douglas A.

Broaddus, Mechanical Engineer Sealed Source Safcty Section Source Containment and Devices Branch Division of Industrial and Medical Nuclear Safety, NMSS

Enclosure:

As stated cc: SKimberley, LFDCB (w/ encl.)

Distribution:

Registration files noted in Enclosure (2)

SSSS Staff NMSS r/f SCDB r/f SSSS r/f IMNS Central Files FBrown n:.

OFC SCDB NAME:

DB$h!ddus DATE:

07/p/ /93 OFFICIAL RECORD COPY D:\\AECL_NOR. CMP

7 O

o Enclosure (1)

The following certificates for AECL have been transferred to

" inactive" status.

1 Old Certificate #

New Certificate #

Model Numbers NR-0169-D-118-U NR-8003-S-801-S GAMMACELL 100 NR-0169-D-121-U NR-8003-S-802-S GAMMACELL 100 NR-0169-S-113-U NR-8003-S-803-S C-110 NR-0169-S-122-U NR-8003-S-804-S AC-110 NR-0169-S-123-U NR-8003-S-805-S AC-231 NR-0169-D-134-U NR-8003-S-806-S GAMMABEAM 100A,B,C NR-0169-S-115-U NR-8003-S-807-S C-166 NR-0169-S-116-U NR-8003-S-808-S C-167 NR-0169-S-125-U NR-8003-S-809-S C-170 NR-0169-S-126-U NR-8003-S-810-S C-171 NR-0169-S-101-U NR-8003-S-811-S C-175 NR-0169-S-130-S NR-8003-S-813-S C-182 NR-0169-S-150-U NR-8003-S-814-S C-185 NR-0169-S-128-U NR-8003-S-815-S C-199 NR-0169-S-129-U NR-8003-S-816-S C-200 NR-0169-S-156-S NR-8003-S-817-S C-7.225/C-236 NR-0169-S-137-U NR-8003-S-818-S C-230 NR-0169-S-133-U NR-8003-S-819-S C-277, C-278 NR-0169-S-127-U NR-8003-S-820-S C-177 NR-0169-S-159-U NR-8003-S-821-S-4493-97 NR-0169-S-135-S NR-8003-S-822-S C-281 NR-0169-S-136-U NR-8003-S-823-S C-283 NR-0169-S-138-S NR-8003-S-824-S C-285 NR-0169-S-139-S N,R-8003-S-825-S C-295 NR-0169-S-102-U NR-8003-S-826-S XC-216 NR-0169-S-131-S NR-8003-S-827-S XC-257 NR-0169-S-145-S NR-8003-S-828-S XC-326 NR-0169-S-143-S NR-8003-S-829-S XC-298, XC-305 NR-0169-S-105-S NR-8003-S-830-S C-161

i O

O i

Enclosure (1)

I The following certificates have been transferred from AECL to Nordion.

Old certificate #'s New Certificate #

Model Numbers NR-0169-S-142-S and NR-0220-S-103-S' C-188, C-306 NR-0169-S-144-U NR-0169-S-157-S NR-0220-S-104-S C-324/C-236 NR-0169-D-117-S and NR-0220-D-105-S GAMMABEAM 150 Series, C-174 NR-0169-S-114-U NR-0169-S-158-U NR-0220-S-106-S C-265 NR-0169-D-119-U and NR-0220-D-107-S GAMMACELL 220, C 198 NR-0169-S-151-S NR-0169-S-162-S NR-0220-D-108-S C-349 NR-0169-S-161-S NR-0220-S-801-S C-235/C-236

,