Text
-
k March 6, 1998 APPLICANT: Westinghouse Electric Company FACILITY:
AP600
SUBJECT:
SUMMARY
OF MEETING WITH WESTINGHOUSE TO DISCUSS THE STATUS OF THE Dt! SIGN CERTIFICATION REVIEW OF THE AP600 The subject meeting was held in the Rockville, Maryland, office of the Nuclear Regulatory Commission (NRC) between representatives of Westinghouse and the NRC staff on January 22, 1998. The purpose of the meeting was to discuss the status of the open issues resulting from the design certification review of the AP600. Attachment 1 is a list of meeting attendees.
The participants discussed the results of the technical meetings that had just taken place on issues in Chapters 6,15, and 1g of the standard safety analysis report. Then, the status and j
expected submittal dates for certain key licensing issues were discussed, as follows.
A management meeting to discuss the issues on contains.1ent coatings needed to be set up within the next 2 weeks. Mr. Sheron was designated to be the decision-making authority for the office for any appeal on this issue.
The staff identified a rember of issues during their quality assu.ance audit. A letter and followup report was expected to be issued shortly to discuss the staff's concems.
The information requested on the WGOTHIC code was expected to be submitted by Westinghouse on January 27,1998.
Westinghouse was planning to submit revised design descriptions to address the staff's concems on the level of detail in the inspections. Tests, Analyses, and Acceptance Criteria document.
At the conclusion of the meeting, dates for upcoming meetings and remaining work were j
discussed. A draft of this meeting summary was provided to Westinghouse to allow them the opportunity to comment on the summary prior to issuance.
original signed hy Thomas J. Kenyon, Project Manager Standardization Project Directorate Division of Reactor Program Management
/
Office of Nuclear Reactor Regulation f
4 Docket No.52-003 h
A"achment: As stated e,.C: See next page B 3JRif UTION: See next page
[
DOCUMENT NAME: A:\\SMM_1_22. SUM Te receive a copy of this document, indicate in the box: "C" = Copy without attachment / enclosure "E" = Copy with cttachment/enclost(pe "N" = Na copy OFFICE PM:PDMitPM l D:PCST:DRPM l l
l NAME-TJKeny66:sg TRQuay ~H40 DATE 03//> /98 03/ (,/98 9803120414 980306 OFFICIAL RECORD COPY $hhdhh h-t PDR ADOCK 05200003 et PDR J
(
Westinghouse Electric Corporation Docket No.52-003 l
cc:
Mr. Nicholas J. Liparulo, Manager Mr. Frank A. Ross Nuclear Safety and Regulatory Analysis U.S. Department of Energy, NE-42 Nuclear and Advanced Technology Division Office of LWR Safety and Technology Westinghouse Electric Corporation 19901 Germantown Road P.O. Box 355 Germantown, MD 20874 Pittsburgh, PA 15230 Mr. Russ Bell Mr. B. A. McIntyre Senior Project Manager, Programs Advanced Plant Safety & Licensing Nuclear Energy Institute Westinghouse Electric Corporation 1776 i Street, NW Energy Systems Business Unit Suite 300 Box 355 '
Washington, DC 20006-3706 Pittsburgh, PA 15230 Ms. Lynn Connor Ms. Cindy L. Haag Doo-Search Associates Advanced Plant Safety & Licensing Post Office Box 34 j
l Westinghouse Electric Corporation Cabin John, MD 20818 J
Energy Systems Business Unit l
Box 355 Dr. Craig D. Sawyer, Manager Pittsburgh, PA 15230 Advanced Reactor Programs GE Nuclear Energy Mr. M. D. Beaumont 175 Cuttner Avenue, MC-754 Nuclear and Advanced Technology Division San Jose, CA 95125 Westinghouse Electric Corporation One Montrose Metro Mr. Robert H. Buchholz 11921 Rockvi;;e Pike GE Nuclear Energy Suite 350 175 Curtner Avenue, MC-781 Rockville, MD 20852 San Jose, CA 95125 Mr. Sterling Franks Barton Z. Cowan, Esq.
U.S. Department of Energy Eckert Seamans Cherin & Mellott NE 50 600 Grant Street 42nd Floor 19901 Germantown Road Pittsburgh, PA 15219 Germantown, MD 20874 Mr. Ed Rodweg, Manager Mr. Charles Thompson, Nuclear Engineer PWR Design Certification AP600 Certification Electric Power Research Institute NE-50 3412 Hillview Avenue 19901 Gerr'antown Road Palo Alto, CA 94303 Germantown, MD 20874 Mr. Robert Maiers, P.E.
Pennsylvania Department of Environmental Protection Bureau of Radiation Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469 i
I
s I
i DISTRIBUTION w/ attachments:
Docket File PUBLIC PDST R/F TKenyon BHuffman JSebrosky DScaletti JNWilson SMagruder JHWilson MDunsaniwskyj
' DISTRIBUTION w/o attachments:
SCollins/FMiraglia, 0-12 G18 BSheron,0-12 G18 BBoger,0-12 G18
'JRoe DMatthews TQuay.
ACRS (11)
JMoore,0-15 B18 NDudley, T-2 E26 l
i l
I i
AP600 MANAGEMENT MEETING MEETING ATTENDEES JANUARY 22,1998 NAME ORGANIZATION a
THOMAS KENYON NRR/DRPM/PDST JACK ROE NRR/DRPM TED QUAY NRR/DRPM/PDST DINO SCALETTI NRR/DRPM/PDST BOB VIJUK W
BRIAN MCINTYRE W
SUSAN FANTO W
CHARLES THOMPSON DOE ROBERT MAlERS PA/DEP - BRP LYNN CONNOR DSA NOEL DUDLEY ACRS BILI. HUFFMAN NRR/DRPM/PDST l
I i
Attachment