.__

/

'o,,

UNITED STATES E

NUCLEAR REGULATORY COMMISSION o

7, t

WASHINGTON, D. C. 20666

\\*****

October 30, 1986 Docket No. 50-213 Mr. John F. Opeka, Senior Vice President Nuclear Engineering and Operations Connecticut Yankee Atomic Power Company Post Office Box 270 ilartford, Connecticut 06141-0270

Dear Mr. Opeka:

SUBJECT:

TECHNICAL SPECIFICATIONS FOR MANUAL CONTAINMENT ISOLATION VALVES Re:

Haddam Neck Plant The Conmission has issued the enclosed Amendment No. 86 to Facility Operating License No. DPR-61 for the Haddam Neck Plant. This amendment is in response to your application dated August 29, 1986.

The license amendment adds a second note of clarification to the definition of containment integrity in Technical Specification 1.8.2.b to permit normally closed manual isolation valves SI-V-863 A, B, C, and D to be opened for periodic surveillances.

In addition, the amendment permits valve SA-V-413 i

to be opened, as required, to assure the operability of the containment continuous leak monitoring system and to allow for additional infrequent maintenance activities when containment integrity is presently required.

Valves SI-V-863 A, B, C, and D are in the high pressure safety injection system. Periodic surveillance of these valves has been determined to be important from a safety standpoint because they can be used to ensure that safety injection check valves (SI-CV-862, A, B, C, and D) are passing flow, there is proper boron concentration in the recirculation line, and any j

precipitated boron in the system is either flushed or redissolved into solution. Similarly, the licensee has determined that periodic operation of valve SA-V-413 would enhance operability of the containment continuous leak monitoring system and, as necessary, maintain the containment pressure within technical specification limits by injecting outside air to maintain a slightly positive pressure.

A Notice of Consideration of Issuance of Amendment to License and Proposed No Significant Hazards Consideration Determination and Opportunity for Hearing related to the requested action was published in the FEDERAL REGISTER on September 24, 1986 (51 FR 33947). No comments or requests for hearing were received, i

8611050376 861030 PDR ADOCK 0500 3

5c-2t3

. ~

A copy of our related Safety Evaluation is enclosed. This action will appear in the Commission's biweekly. notice publication in the FEDERAL REGISTER.

4 Sincerely, i

Original signed by: F. Akstulewicz 4

i Francis M. Akstulewicz, Jr.

Integrated Safety Assessment i

Project Directorate j

Division of PWR Licensing - B

Enclosures:

1.

Amendment No. 86 to License No. DPR-61 2.

Safety Evaluation cc w/ enclosures:

l See next page DISTRIBUTION l

Q M+"r OGC-Bethesda

~NRC PDR ELJordan 4

Local PDR BGrimes ISAP Reading JPartlow NSIC ACRS(10)

RDiggs TBarnhart(4)

FMiraglia LJHarmon FAkstulewicz WRegan PAnderson WJones l

OELD CMiles, OPA MBoyle AWang i

l l

4 4

DPL-B:ISAP

/k DP DPL-PEICSB DPL-B:ISA OGQ-thesda FAkstulewicz:lt PA rson JCalvo CGrimes

(

4 i

10/g,/86 10/ /86 10/+)/86 10/3c/86 1d/a['/ 6 i

i 4

2 '.-

A copy of our related Safety Evaluation is enclosed. This action. will appear in the Corsnission's biweekly notice publication in the FEDERAL REGISTER.

Sincerely.

- gwW. 01 Francis M. Akstulewicz, Jr Integrated Safety Assessment s.

Project Directorate Division of PWR Licensing - B

Enclosures:

1.

Amendment No. 86 to License No. DPR-61 2.

Safety Evaluation cc w/ enclosures:

See next page 4

l

'l

Mr. John F. Opeka Connecticut Yankee Atomic Power Company Haddam Neck Plant CC:

Gerald Garfield, Esquire Kevin McCarthy, Director Day, Berry & Howard Radiation Control Unit Counselors at Law Department of Environmental a

City Place Protection Hartford, Connecticut 06103-3499 State Office Building Hartford, Connecticut 06106 Superintendent Haddam Neck Flant Richard M. Kacich, Supervisor RDF #1 Operating Nuclear Plant Licensing Post Office Box 127E Northeast Utilities Service Company East Hampton, Connecticut 06424 Post Office Box 270 Hartford, Connecticut 06141-0270 Edward J. Mroczka Vice President, Nuclear Operations Northeast Utilities Service Canpany Post Office Box 270 Hartford, Connecticut 06141-0270 Board of Selectmen Town Hall Haddam, Connecticut 06103 State of Connecticut Office of Policy and Management ATTN: Under Secretary Energy Division 80 Washington Street Hartford, Connecticut 06106 Resident Inspector Haddam Neck Nuclear Power Station c/o U.S. NRC P. O. Box 116 East Haddam Post Office East Haddam, Connecticut 06423 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406

- - -.