r i

October 24, 1986 Docket No. 50-155 Mr. Kenneth W. Berry Director - Nuclear Licensing Consumers Power Company 1945 West Parnall Road Jackson, Michigan 49201

Dear Mr. Berry:

i

SUBJECT:

RESPONSE TO GENERIC LETTER 86-02, TECHNICAL RESOLUTION OF GENERIC ISSUE B-19, THERMAL HYDRAULIC STABILITY (TAC 60780)

Re: Big Rock Point Plant

\\

\\

NRC staff has received your response to Generic Letter (GL) 86-02 dated October 13, 1986. Although a response to GL 86-02 was not required, the Big Rock Point Plant Project Manager requested a response from Consumers Power Company (CPC) due to the unique design of the Big Ro,ck Point Plant.

The reanalysis of the thermal hydraulic stability margin for the Big Rock Point Plant is understood by NRC staff to be well within the margin specified in GL 86-02 (i.e., a decay ratio of less than or equal to 0.75). The least stable condition for the Big Rock Point Plant is calculated at 0.46.

NRC staff finds this value to be within the margin specified in GL 86-02 and is therefore acceptable.

NRC staff notes CPC response to this special request.

Sincerely, Original signed by John A. Zwolinski, Director BWR Project Directorate #1 Division of BWR Licensing cc: See next page Distribution:

Docket File BGrimes NRC & L PDRs OGC-Bethesda Branch Files JPartlow TRotella ACRS-10 CJamerson NThompson JZwolinski RBernero 8610290424 e61024 ADOCK 0500 5

Edordan gDR BWRf1 BWR#1 BWR#1 CJamerson TRotella JZwolinski is h /86 i) 10/24/86 go ///86 l

Mr. Kenneth W. Berry Consumers Power Company Big Rock Point Plant cc:

Mr. Thomas A. McNish, Secretary Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Big Rock Point Plant ATTN: Mr. David P. Hoffman Plant Superintendent Route 3 Post Office Box 591 Charlevoix, Michigan 49720 Mr. I. Lee Moerland Chairman, Board of Commissioners P. O. Box 218 Charlevoix, Michigan 49720 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 Regional Administrator Nuclear Regulatory Commission, Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Nuclear Facilities and Environmental Munitoring Section Office Division of Radiological Health P. O. Box 30035 Lansing, Michigan 48909 Resident Inspector Big Rock Point Plant c/o U.S. NRC RR #3, Box 600 Charlevoix, Michigan 49720