Ctmmsow; ann cucun One First National Piara. CNcago, lilinois Address R: ply to: Post OflIc'e'B:x 7M Chicrgo. Ithres 60690 r
April 19, 1976 Mr. Robert A. Purple, Chief operating Reactors - Branch 1 Division of operating Reactors U.S. Nuclear Regulatory Commission Washington, D.C.
20555
Subject:
Zion Station Unit 1 License No. DPR-39 NRC Docket No. 50-295
Dear Mr. Purple:
The following is in response to your request for addi-tional information relative to the Zion Unit 1 reload safety evaluation.
The attachment addresses the small break LOCA reanalyses as discussed by a conference telephone call between Westinghouse, Coremonwealth Edison, Walter Higgins of your staff, and Messrs.
R. Satterfield and B. Buckley of the NRC staff on April 8,1976.
Very trul
- yours,
& lsfo n.Jbl /
G., J. Pli:al Nuclear Licensing Administrator Pressurized Water Reactors Attachment l
l l