ML20215L152

From kanterella
Jump to navigation Jump to search
Comments on ACRS DHR Subcommittee 860909 Meeting.Plethora of Programs Re Auxiliary Feedwater Sys Should Be Coordinated to Limit Waste & Broaden Perspectives
ML20215L152
Person / Time
Issue date: 09/17/1986
From: Davis P
Advisory Committee on Reactor Safeguards, PRD CONSULTING
To: Ward D
Advisory Committee on Reactor Safeguards
References
REF-GTECI-124, REF-GTECI-A-44, REF-GTECI-A-45, REF-GTECI-DC, REF-GTECI-EL, REF-GTECI-NI, TASK-124, TASK-A-44, TASK-A-45, TASK-OR ACRS-CT-1860, NUDOCS 8610280500
Download: ML20215L152 (2)


Text

~

~

dB /f/d 4.-

PRD CONSULTING P. R. Davis, President RECElVED 1935 Sabin Dr.

Idaho Falls,ID 83401

'86 SEP 25 P1 16 (208) 529-2861 Sept.17 1986 n

~

~

GUAP 0

Mr. Dave Ward

.. Advisory Committee on Reactor Safeguards

~ U.S. Nuclear Regulatory Commission Washington, DC 20555

Dear Dave,

l did not get a chance during the Decay Heat Removal Subcommittee meeting last week (Sept. 9) to express one additional comment regarding the general subject of auxillary feedwater systems, so I will take the opportunity to deliniate it in this letter. My concern relates to the plethora of NRC programs which seem to have AFS as their focus, but which do not seem coordinated, consistent, or to utilize a framework which assures an optimum identification and resolution of AFS problems with respect to safety. These programs include.

I Generic Issue 124-Auxiliary Feedwater Rellability.

2 USI A-44 -Plant Blackout (AC and DC power reliability are the primary concerns, but reliability of auxtliary feedwater is an important element) 3 V',1 A-45-Decay Heat Pemoval 4 Se.e:r Accident pc hcv Statenient-Incaidual plant Examination (This procram, a5 f unde"Sta'd :t, w!!! p:are empna.!S on AFS reitability) 5 Safety System Functional inspection-A deterministic examination of AFS (I expressed concerns with this approach at the Sept 9 meeting) 6 B&W plant examination program-This consists of both the B&W Owners Group activity as well as NRC programs. These activities examine only B&W reactors with principal focus on AFS. (I note that 3 of the seven l

plants targeted f or examination as part of GI-124 are B&W plants )

LESIc. ATE] GRIGINAL

[/2d Certified By 3

PCR

J

.y ~ ~

it seems to me that there are considerable resources being Wasted in pursuing all of these programs, and it is possible that AFS modifications may be mandated which are detrimental to safety because the various programs are not coordinated, and many of them do not seem to address the issue from a broad enough perspective.

Sincerely,

^

9 O