r DUKE POWER GOMPANY P.O. BOX 33189 CHARLOTTE, N.C. 28242 HALH. TUCKER TELEPHOME g\\\\. p goy om.um g
September 2, 1986 Dr. J. Nelson Grace, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Re: Oconee Nuclear Station, Unit 1 Docket No. 50-269
Dear Dr. Grace:
Pursuant to Oconee Nuclear Station Technical Specification 4.~17.6(a), Duke Power Company (Duke) is providing the following information concerning the Oconee Unit 1 steam generators. The following steam generator tubes were plugged during a recent Unit 1 maintenance outage. The "A" OTSG had a total of 21 tubes plugged while the "B" OTSG had 2 tubes plugged.
Very truly yours,
')h/RL/49"t. -
Hal B. Tucker WHM/13/slb Attachments xc:
Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C.