Forwards Safety Insp Rept 50-483/87-10 on 870405-0531.No Violations Noted
ML20215H789
Person / Time
Site: Callaway Ameren icon.png
Issue date: 06/18/1987
From: Forney W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Schnell D
UNION ELECTRIC CO.
Shared Package
ML20215H791 List:
References
NUDOCS 8706240213
Download: ML20215H789 (2)


See also: IR 05000483/1987010

Text

'

fmb

...

d'

JUNT 8198L q

!

-Docket No. 50-483

Union Electric Company

ATTN: Mr. Donald F. Schnell

Vice President - Nuclear

Post Office Box 149 - Mail Code 400

St. Louis, MO 63166 j

Gentlemen:

This refers to the routine safety inspection conducted by Messrs. B. H. Little

and C. H. Brown of this office on April.5 through May 31, 1987, of activities

at Callaway Plant, Unit 1, authorized by NRC Operating License No. NPF-30 and

to the discussion of our findings with Mr. J. D. Blosser and others of your

staff at the conclusion of the inspection.

The enclosed copy of our' inspection report identifies areas examined during

the inspection. Within these areas, the inspection consisted of a selective

examination of procedures and representative records, observations, and

interviews with personnel.  !

No violations of NRC requirements were identified during the course of this

inspection.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of

this letter and the enclosed inspection report will be placed in the NRC

Public Document Room..

We will gladly discuss any questions you have concerning this inspection.

Sincerely,

l[g62$$$$k$[ Oho $ea M . M % 5. L. Forneyn i

G PDR

W. L. Forney, Chief,

Reactor Projects Branch 1

Enclosure: Inspection Report

No. 50-483/87010(DRP)

See Attached Distribution

r v\

Q

RIII RIII

2

RII L N r m;

i

..

_,

Union Electric Company '2 JUN 18 $874

Distribution

cc'w/ enclosure:

G. L.' Randolph, General

Manag7r, Nuclear Operations

A. P. Neuhalfen , Manager,

~ Quality Assurance

DCS/RSB(RIDS)

Licensing'. Fee Management Branch

Resident Inspector, RIII

. Technical Support Section, DRP-RIII

Region IV

Resident Inspector, Wolf Creek

K. Drey

Chris R. Rogers, P...E.

.

'

Utility Division, Missouri

Public Service' Connission