Alabama Power Company 600 North 18th Street Post Office Box 2641 Birmingham, Alabama 35291-0400 Telephone 205 250-1835 AlabamaPbwer sMW Mtsp nio V ce r sident October 8, 1986 Docket No. 50-364 Director, Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Attention: Mr. E. A. Reeves Gentlemen:
Joseph M. Farley Nuclear Plant - Unit 2 RCS Heatup and Cooldown Curves Replacement Pages Enclosed are proposed replacement pages for Farley Nuclear Plant Unit 2 Technical Specifications pages 3/4 4-29, 3/4 4-30 and B 3/4 4-10.
These pages contain figures related to the Unit 2 Heatup and Cooldown Curves Technical Specification change which were issued as part of License Amendment No. 55 dated April 22, 1986. The replacement pages have been verified by Alabama Power Company to contain the same information as those previously issued, but are of much higher quality. Alabama Power Company requests that these replacement pages be issued as corrected pages.
If there are any questions, please advise.
Respectfully submitted, ut. 4. /M,p --
R. P. Mcdonald RPM /J AR :k pc-D-T.S.6 Enclosures cc: Mr. L. B. Long Dr. J. N. Grace Mr. W. H. Bradford Dr. C. E. Fox f
col SBA*%BBERIIg4 P
~
i MATERIAL PROPERTY BASIS CONTROLLING MATERI AL. R.V.lNTERMEDIATE SHELL COPPE R CONTENT 0.20 WT%
PHOSPHORUS CONTENT 0.018 WT%
INITIAL RT E
NOT 1
- 1/4T, W F NOT 8
- 3/4T, 83 F CURVES APPLICA8LE FOR HEATUP RATES UP TO 60* F/HR FOR THE SERVICE PERIOO UP TO 8 EFPY 3000.0 i
l l
I i
LEAK TEST LIMIT.
f j
j N
J f
f f
J J
l UNACCEPTABLE f
f e
OPERATION f
j j
t 2000.0 7
I
/
j w
i e
3 HEATUP RATES UP f
f l
h TO 600 F/HR f
j E
Y
/
O P
f l
)
m f
f ACCEPTABLE l
(
/
OPERATION l
f r
1000.0
/
/
- CRITICALITY LIMIT i
/
BASED ON INSERVICE HYDROSTATIC TEST TEMPERATURE (2740 F)
I FOR THE SERVICE PERIOD UP TO 8 EFPY I
l O.0 j
0.0 100.0 200.0 300.0 400.0 500.0 INDICATED TEMPERATURE (OF)
FIGURE 3.4-2 FARLEY UNIT 2 REAC10R COOLANT SYSTEM HEATUP LIMITATIONS APPLICABLE FOR THE FIRST 8 EFPY i
r CORRECTED PAGE l
FARLEY - UNIT 2 3/4 4-29 AMENDMENT N0. 55 i
4
-+=-----yevw
.---=r etw -y-mvm vm - v w-e'-
- = - - - - - -
~
MATERIAL PCOPERTY CAsis CONTROLLING MATERI AL R.V. INTE RMEDI AT E SHELL COPPE R CONTENT 0.20 WT%
PHOSPHORUS CONTENT r 0.018 WT%
INITIAL RT
-10' F NDT RT AFTER S EPPY 1/4T,148' F NOT 8
- 3/4T, 83 F CURVES APPLICABLE FOR COOLDOWN R ATES UP TO 100* F/HR FOR THE SERVICE PERIOO UP TO 8 EFFY l
3000.0 I
I
)
J J
I f
}
g 2000.0
-= UNACCEPTABLE I
OPERATION 3
E L
11llll f
L E
llllll
)
llllll J
8 h
lllllg j
ACCEPTABLE m
OPERATION llllll t
=
S llllll
/
E llllll
/
llllll
/
E llll-ll /
I1111L F COOLDOWN R ATES- --
0F/HR 0
~ 20 5 sa Hp yfllII
~
7 lll1ll do E-
_"s IIIIll
~'
llllll lll111 lIIIII o,o 0.0 100.0 200.0 300.0 400.0 500.0 INDICATED TEMPERATURE (OF)
FIGURE 3.4-3 FARLEY UNIT 2 REACTOR COOLANT SYSTEM C00LDOWN LIMITATIONS APPLICABLE FOR THE FIRST 8 EFPY FARLEY - UNIT 2 3/4 4-30 kObbMfh r 55
7 20 10 9
8 7
6 5
/ SURFACE j
4 f
a e
1/4T -
3 r
/
p 2
2
[
/
s f
f
/
1018
/
s 9
i
/
8 I
/
7 s 3/4T-l l
6 f~
~
(
j (j
Ng 0
s 2
i I
/
S 4
m
/
/
f E
I (
j 3
7Y, f
w j
?
f
'l
)
SL.
l z
2
[
O l
/
~i
/
/
/
18 10
/
9 I
8 7
?
A 6
5 I
I
(
4 I
,I 3
2 17 10 5
to 15 20 25 30 35 SERVICE LIFE (EFFECTIVE FULL POWER YEARS)
FIGliRE B 3/4.4-1 FAST NEUTRON FLUENCE (E>l Mey) AS A FUNCTION OF FULL POWER SERVICE LIFE (EFPY)
CORRECTED PAGE FARLEY - UNIT 2 8 3/4 4-10 AMENDMENT N0. 55