ce Prrs d t Nxlear Opratims Y$isonESE*
" W --
December 12, 1986 VP-86-0149 Office of Nuclear Reactor Regulation Ms. Elinor G. Adensam, Director Project Directorate No. 3 Division of BWR Licensing U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Dear Ms. Adensam
References:
1)
Fermi 2 NRC Docket No. 50-341 NRC License No. NPF-43 2)
Safety Evaluation Report Related to the Operation of Fermi 2 (NUREG-0798) dated July 1, 1981, and Supplements 1, 2, 3 and 5 3)
Detroit Edison to NRC Letter, " Detroit Edison Response to 10CFR50.49",
EF2-65,629 dated November 1, 1983 4)
Detroit Edison to NRC Letter,
" Additional Environmental Qualification Information Requested by the NRC",
EF2-66,759, dated January 16, 1984
Subject:
Fermi 2 Compliance with the Provisions of 10CFR50.49 It is required by Reference 1, License Condition 2.C(6) and Reference 2, Supplement 5, Section 3.11.6 that Detroit Edison shall environmentally qualify all electrical equipment according to the provisions of 10CFR50.49 by November 30, 1985.
Detroit Edison previously provided a series of letters documenting our compliance to 10CFR50.49.
References 3 and 4 provided the details of the Fermi 2 Equipment Qualification Program as compared to the requirements of 10CFR50.49.
The NRC review and acceptance of Fermi 2's compliance to 10CFR50.49 was documented in Reference 2, Supplement 5, Section 3.11.
8612230387 B61212 o
O
[
PDR ADOCK 05000341 (h
E PDR D
Ms. Elinor G. Adanstm December 12, 1986 VP-86-0149 Page 2 Detroit Edison is hereby informing you that actions required by~the NRC in Reference'2 and the Fermi 2 license to environmentally qualify identified electrical components were completed by November 30, 1985.
This letter documents our compliance with the requirements of Fermi 2 License Condition 2.C(6).
Should you require any further information or clarifications, please contact Mr. T. Randazzo, (313) 586-4320.
Sincerely,
'df M
~
cc:
Mr. W. G. Rogers Mr. J. Stefano Mr. G. C. Wright USNRC Document Control Desk Washington, D. C. 20555