DUKE POWER GOMPANY P.O. BOX 33189 CHARLOTTE, N.C. 28242 HAL B. TUCKER ratzenown um r==7 (704) 373-4531 December 12, 1986 U. S. Nuclear Regulatory Commaission Attention: Document Control Desk Washington, D. C. 20555

Subject:

Catawba Nuclear Station, Unit 1 Docket No. 50-413 Steam Generator Tube Inspection

Dear Sir:

Pursuant to Technical Specification 4.4.5.5 and 6.9.2, an in-service inspection of Catawba Nuclear Station, Unit 1 Steam Generators (S/G) A, B, C, and D was complete %

on August 31, 1986. One tube in S/G "A" was found to have indications of 20% WD.

No other degraded tubes were found in any of the S/G's and zero tubes were plugged as the result of these indications.

Very truly yours,

& k-Hal B. Tucker JGT/19/slb xc:

Dr. K. Jabbour Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C.