ML20215F048

From kanterella
Jump to navigation Jump to search
Advises That Inservice Insp of Steam Generators A,B,C & D Completed on 860831,per Tech Specs 4.4.5.5 & 6.9.2.One Tube in Steam Generator a Found to Have Indications of 20% Twd. No Tubes Plugged as Result of Indications
ML20215F048
Person / Time
Site: Catawba Duke Energy icon.png
Issue date: 12/12/1986
From: Tucker H
DUKE POWER CO.
To:
NRC OFFICE OF ADMINISTRATION (ADM)
References
NUDOCS 8612230238
Download: ML20215F048 (1)


Text

-

DUKE POWER GOMPANY P.O. BOX 33189 CHARLOTTE, N.C. 28242 HAL B. TUCKER ratzenown um r==7 (704) 373-4531 December 12, 1986 U. S. Nuclear Regulatory Commaission Attention: Document Control Desk Washington, D. C. 20555

Subject:

Catawba Nuclear Station, Unit 1 Docket No. 50-413 Steam Generator Tube Inspection

Dear Sir:

Pursuant to Technical Specification 4.4.5.5 and 6.9.2, an in-service inspection of Catawba Nuclear Station, Unit 1 Steam Generators (S/G) A, B, C, and D was complete %

on August 31, 1986. One tube in S/G "A" was found to have indications of 20% WD.

No other degraded tubes were found in any of the S/G's and zero tubes were plugged as the result of these indications.

Very truly yours,

& k-Hal B. Tucker JGT/19/slb xc:

Dr. K. Jabbour Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C.

20555 NRC Resident Inspector Catawba Nuclear Station Dr. J. Nelson Grace, Regional Administrator U. S. Nuclear Regulatory Connaission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 8612230238 861212 ADOCKOSOog3 g7 DR i/o i