ML20215E136

From kanterella
Jump to navigation Jump to search
Discusses Review of 860814 Response to Request for Addl Info Re Sser 3 Open Item 17 Re Training for Mitigating Core Damage & Licensed Operator Training (TMI Item I.A.2.1). Two-day Training Insufficient to Cover All Lesson Matl
ML20215E136
Person / Time
Site: Vogtle  
Issue date: 10/08/1986
From: Jacqueline Thompson
Office of Nuclear Reactor Regulation
To: Conway R
GEORGIA POWER CO.
References
TASK-1.A.2.1, TASK-TM NUDOCS 8610150073
Download: ML20215E136 (4)


Text

p.n uauq(g UNITED STATES yy j;

NUCLEAR REGULATORY COMMISSION L

.J j

WASHINGTON, D. C. 20555

\\...../

0 8 OCT 1986 Docket Nos.:

50-424 and 50-425 Mr. Richard Conway Vice President and Project General Manager Georgia Power Company Route 2, Box 299A Waynesboro, Georgia 30830

Dear Mr. Conway:

Subject:

Vogtle Electric Generating Plant, Open Item 17:

Training Program We have reviewed your August 14, 1986, response to our request for additional information regarding the issues of training for mitigating core damage and licensed operator training. The mitigating core damage lesson plans are suf-ficient in content to meet the criteria for training for mitigating core damage contained in Enclosure 3 of H. R. Denton's letter of March 28, 1980, (TMI Action Item I.A.2.1).

However, we believe that the proposed 2-day dur-ation of training for mitigating core damage may not be sufficient to permit coverage of all the lesson material and allow for trainee evaluation. Also, simulator training is needed to supplement the classroom training and to inte-grate the mitigating core damage training with emergency procedures, transient and accident analysis training.

The other licensed operator training materials we have reviewed are generally acceptable with several comments. The lesson plans for fuel handling systems and operations training include no reference to industrial and radiation safety in fuel handling operations, control rod storage and installation in the core, or integration of fuel handling operations with control room staff. There ap-pears to be no on-the-job training or practice with fuel handling equipnent.

Lesson plans for training in technical specifications and license cor.ditions appear to be adequate.

In teleconferences on July 28 and 31, 1986, the issues related to instructor qualification and requalification, nonlicensed personnel training, and records of plant personnel training were discussed.

You have not yet submitted FSAR revisions to address these issues.

7 8610150073 861008 PDR ADOCK 05000424 E

PDH

iMr,[R.'Conway At this time, you have not amended the FSAR with sufficient informatien to re-solve all of the issues associated with Open Item 17 (SSER 3). Therefore, the training program remains an open item for Vogtle licensing.

If there are any questions regarding this issue, we will be pleased to discuss them.

Sincerely, p

f' d

,?

i c h ( bl f

1 K l{ $ d John W. Thompson, Project Manager PWpProjectDirectoratefi4 Dirvision of PWP, Licensing-A cc:

See next page P

7 Firf R.'E. Conway-Georgia Power Company Vogtle Electric Generating Plant cc:

Mr. L. T. Gucwa Resident Inspector Chief Nuclear Engineer Nuclear Regulatory Commission Georgia Power Company P. O. Box 572 P.O. Box 4545 Waynesboro, Georgia 30830 Atlanta, Georgia 30302 Mr. Ruble A. Thomas Deppish Kirkland, III, Counsel Vice President - Licensing Office of the Consumers' Utility Vogtle Project Council Georgia Power Company /

Suite 225 Southern Company Services, Inc.

32 Peachtree Street, N.W.

P.O. Box 2625 Atlanta, Georgia 30303 Birmingham, Alabama 35202 James E. Joiner Mr. Donald O. Foster Troutman, Sanders, Lockerman, Vice President & Project General Manager

& Ashmore Georgia Power Company Candler Building Post Office Box 299A, Route 2 127 Peachtree Street, N.E.

Waynesboro, Georgia 30830 Atlanta, Georgia 30303 Danny Feig Mr. J. A. Bailey 1130 Alta Avenue Project Licensing Manager Atlanta, Georgia 30307 Southern Company Services, Inc.

P.O. Box 2625 Carol Stangler Birmingham, Alabama 35202 Georgians Against Nuclear Energy 425 Euclid Terrace Ernest L. Blake, Jr.

Atlanta, Georgia 30307 Bruce W. Churchill, Esq.

Shaw, Pittman, Potts and Trowbridge 2300 N Street, N.W.

Washington, D. C.

20037 Mr. G. Bockhold, Jr.

Vogtle Plant Manager Georgia Power Company l

Route 2, Box 299-A l

Waynesboro, Georgia 30830 1

Regional Administrator, Region II U.S. Nuclear Regulatory Contaission 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323

8 007 1986

. Mr/ R. Conway

,. At this time, you have not amended the FSAR with sufficient information to re-solve all of the issues associated with Open Item 17 (SSER 3). Therefore, the training program remains an open item for Vogtle licensing.

If there are any questions regarding this issue, we will be pleased to discuss them.

Sincerely, John W. Thompson, Project Manager PWR Project Directorate #4 Division of PWR Licensing-A cc: See next page NRC PDR Local PDR PRC System NSIC PWR#4 Rdg MDuncan JThompson P0'Connor MMiller 0GC-Bethesda JPartlow BGrimes EJordan NThompson ACRS(10) l l

PWR#4/p -

PWR#4/DPWR-A PWRf4gPWR-A PWR#4/ PWR-A l

JThom ~

mac P0'Connor ND8/idin BJYoungblood 10/

/86 10/? /86 10/7/86 10g 86 l

L