R
]
.
,
.
q
-
.
z,,
.
-
MM 291987
q
i
I
Docket No. 50-312
f
Sacramento Municipal Utilities District
'
P. O. Box 15830
Sacramento, California 95813
Attention: Mr. G. Carl Andognini
Chief Executive Officer
'i
Gentlemen:
Subject: NRC. Inspection Report
This letter refers to the routine inspection conducted by Mr. W. P. Ang of-
this office on May 4-8, 1987, of activities authorized by NRC License No.
DPR-54, and to the discussions of our findings with Mr. R. Croley.and members of
your staff at the conclusion of the inspection on May 8, 1987.
Areas examined during this inspection are described in the enclosed inspection
report. Within these areas, the inspection consisted of selective
examinations of procedures and representative records, interviews with
personnel, and observations by the inspectors.
-
Based on the results of this inspection, it appears that one of your
l
activities ~ was not conducted in full compliance with NRC requirements, as set
'
forth in the Notice of Violation, enclosed herewith as Appendix A.
Your response to this Notice is to be submitted in_accordance with the
provisions of 10 CFR 2.201 as stated in Appendix A,-Notice of Violation.
Your attention is invited to the results of our inspection of your Critical
Manual Valve Maintenance program contained in paragraph 3.A of the attached
inspection report. We identified discrepancies in four of seven valves that
had been inspected and accepted by your Maintenance Department and sampled by
us. We would appreciate your views regarding these results and how they may
reflect on the effectiveness of the maintenance program.
8706180066 870529
PDR- ADDCK 05000312
1
0
PDR.
g
g
I
-
.
MAY 201987
-2-
In accordance with 10 CFR 2.790(a), a copy of this letter and the enclosures
will be placed in the NRC Public Document Room.
Should you have any questions concerning this inspection, we will be glad to
discuss them with you.
The response directed by this letter and the accompanying Notice is not
subject to the clearance procedures of the Office of Management and Budget as
required by the Paperwork Reduction Act of 1980, PL 96-511.
!
Sincerely,
hkift sh
J. B. Martin
,
Regional Administrator
j
Encicsures:
A.
Notice of Violation - Appendix A
B.
Inspection Report No. 50-312/87-16
cc w/ enclosures:
S. Knight, SMUD
G. Knighton, NRR
R. Colombo, SMUD
G. Kalman, NRR
W. Bigg, SMUD
State of CA
bec w/ enclosures:
RSB/ Document Control Desk (RIDS) (IE01)
Project Inspector
'
Resident Inspector
G. Cook
B. Faulkenberry
J. Martin
Docket File
bec w/o enclosure B:
LFMB
t
M. Smith
Region V
REQUEST COPY J REQUESTAE)Y ] REQ
UESTCOPY] REQUEST [ COPY)!
_ CS
QF,S ' P N0
] YES /( N0
YES / (HO L '
/ N0
] YES / ' N0_/
_
A
@
$
l
l
wpx
Wang / norma
(L iJler
AEChaffee
AJo nson
DFKirschg
5/11 /87
5[\\f/87
5[ /87
5/ /87
Sg/87
'
i
J