2b6

  • [p k

i UNITED STATES NUCLEAR REGULATORY COMMISSION h

j WASHINGTON, D. C. 20555 e

SEP 29 1986 Docket 50-341 hs. Billie Pirner Garde Government Accountability Project Midwest Office IN RESPONSE REFER 3424 Marcos Lane TO FOIA-86-373 AND Appleton, WI S4911 APPEAL 86-A-124

{

}

Dear Ms. Garde:

This is in response to your letter dated May 16, 1986, in which you requested,

)

pursuant to the Freedom of Information Act (FOIA), documents related to hRC l

reviews, inspections and evaluations of the Fermi 2 Health Physics Department, from January 1984 to the present.

The documents identified on enclosed Appendix A are being placed in the hRC Public Document Room (PDR) located at 1717 H Street, NW, Washington, DC 20555, in file folder F01A-86-373 in your name.

Copies of the documents are also being placed in the Local Public Document Room (LPDR) for Fermi located at the Monroe County Library System, 3700 S. Custer Road, Monroe, MI 48161. The decuments identified on enclosed Appendix B are already in the PDR. We have indicated the PDR accession number beside each document description.

Documents identified at numbers 1 through 3 on enclosed Appendix C are bein withheld in their entirety from public disclosure pursuant to Exemption (5)g of the F0IA, 5 U.S.C. 552(b)(5), and 10 CFR 9.5(a)(5) of the Comission's regulations.

Information withheld pursuant to Exemption (5) consists of draf ts or records containing the preliminary advice, opinions, ar,d recomen-dations of members of the staff. Release of this type of information would tend to inhibit the frank and candid exchange of information in future deliberations and thus would not be in the public interest. There are no reasonably segregable factual portions because release of the facts would permit an indirect inquiry into the predecisional process of the agency.

Document 4 on Appendix C is being withheld in its entirety from disclosure pursuant to Exemption (7)(a) of the F0IA, 5 U.S.C.(b)public(7)(A),and 10 CFR 9.5(a)(7)(i) of the Commission's regulations.

Information withheld pursuant to Exemption (7)(A) consists of an investigatory record compiled for law enforcement purposes the release of which would interfere with an ongoing enforcement proceeding.

Release of this information could allow those being investigated to learn the scope, direction, and focus of investigatory efforts, and thus could possibly allow them to take action to shield potential wrongdoing or a violation of NRC requirenents from investigators, gO1 6 860929 GARDE 86-A-124 paa

[

Ms. Garde !

The documents identified on enclosed Appendix D are being released in part and are being placed in PDR folder F01A-86-373 and the LPDR.

Portions of the documents are being withheld from public disclosure pursuant to Exemption (6) of the F0IA, 5 U.S.C. 552(b)(6), and 10 CFR 9.5(a)(6) of the Commission's I

l regulations.

Information being withheld pursuant to Exemption 6 consists of personal information the release of which would constitute a clearly unwarranted invasion of personal privacy.

In addition, portions of Document 3 are being withheld pursuant to Exemption (7)(A) of the F03A, 5 U.S.C. 552(b)(7)(A), and 10 CFR 9.5(a)(7)(i) of the Commission's regulat' ions for reasons noted above.

Pursuant to 10 CFR 9.9 of the NRC's regulations, it has been determined that the information withheld is exempt from production or disclosure, and that its production or disclosure is contrary to the public interest. The persons responsible for this denial are the undersigned and James G. Keppler, Regional Admir,istrator, Region III.

This denial may be appealed to the NRC's Executive Director for Operations within 30 days from the receipt of this letter. As provided in 10 CFR 9.11, any such appeal must be in writing, addressed to the Executive Director for Operations, U.S. Nuclear Regulatory Conmission, Washington, DC 20555, and should clearly state on the envelope and in the letter that it is an " Appeal from an Initial F0IA Decision."

l l

In light of this response, no further action will be taken on your July 16,1986, letter appealing our lack of response to your request.

I Sincerely, aA Donnie H. Grimsley, Director Division of Rules and Records Office of Administration

Enclosures:

As stated l

l

(

Appendix A F0IA 86-373 Documents Being Placed in the POR 1.

Various dates Reports of Calibration (10 pages) 2.

Undated Health Physics Equipment - operation (15 pages) 3.

Undated Health Physic; Equipment - calibration (14 pages) 4.

Undated Tatflh 4.3.7.11-1, Table 3.3.7.12-1 and Ta61'e4.3.7.12-1(10pages) 5.

Undated Access Control (3 pages) 6.

Undated Health Physics - Surveying and Analysis Procedure, Revision 6 (17 pages) 7.

Undated Objectives (2 pages) 8.

Undated Training Progfam Description (5 pages) 9.

04/03/84 Inspection Report No. 50-16/8401 & 50-341/85-05 (5 pages)

10. 04/09/84 Ltr to J. Leman from W. E. Miller re: Closeout of Audit No. A-0A-C-83-04 (11 pages)
11. 04/11/84 Ltr to Detroit Edison from C. Paperiello re:

[

analytical results (5 pages)

12. 05/24/84 Notes on Tech Specs (8 pages)
13. 08/22/84 Ltr to B. J. Youngblood from W. Jens re:

Radiation Protection Manager (RPM) Qualifications (9 pages) 14.

09/30/84 Memo to D. Eisenhut from M. Lynch re:

NRR SALP Input for Fermi 2 (6 pages) 15.

10/01/84 Notes from SALP report (draft) (3 pages) 16.

11/01/84 Ltr to B. Youngblood from Detroit Edison re:

Clarification of Position Regarding NUREG-0737 Post-Accident Sampling and Monitoring Capabilities (7 pages) 17.

11/27/84 Memo to R. L. Anderson from J. M. Tozser re:

Sample Line Loss Correction Factors for the SPING and AXM Sample Lines on the SGTS (8 pages)

Appendix A (cont'd)

F0IA 86-373

18. 11/28/84 Memo to Multiple Addressees from E. Schweibinz re:

SALP Board Meeting - Fermi (8 pages)

19. 12/12/84 Response Test Data (13 pages) 20.

12/13/84 Ltr to B. J. Youngblood re: Additional Clarification of Position Regarding NUREG-0737 Post-Accident Sampling and Monitoring Capabilities (10 pages)

21. Undated Diagram Reactor W:ter Cleanup Filter Demineralizers (4pages)
22. Undated Waste Collector System Diagram (16 pages) 23.

1985 Detroit Organization charts (4 pages)

24. 01/31/85 Technical Section Surveillance (20 pages)
25. 03/85 EF-2-FSAR (4 pages)
26. 03/14/85 Course Approval (2 pages)
27. 04/24/85 Certificate of Conformance (2 pages)
28. 05/16/85 Ltr to B. J. Youngblood from W. Jens re: Post-Accident Sampling and Analyses of Plant Effluents (Radioiodines and Particulates) (4 pages)
29. 05/24/85 Ltr to US NRC from Detroit Edison re: Transmittal of Licensee Event Report No. 85007(5pages)
30. 05/28/85 Ltr to S. Veale from D. Dumas re:

Impact of CRD Rebuild on Radwaste Group (6 pages)

31. 06/20/85 Memo to Multiple Addressees from E. Schweibinz re:

SALP Board Meeting - Fermi (7 pages)

32. 06/27/85 Ltr to US NRC from Detroit Edison re: Transmittal of Licensee Event Report No. 85020
33. 07/13/85 Test Analysis Report (219 pages)
34. 07/31/85 Sample Air Flow Rates (1 page)
35. 08/30/85 Ltr to US HRC from Detroit Edison re:

semi-annual radiological effluent release report (29 pages) 36.

10/08/85 Filter Housings (2 pages) 2

g-i.

Appendix A (cont'd)

F0IA 86-373 37.

10/10/85 Ltr to J. Keppler fron Detroit Edison re: reactor operations improvement plan (17 pages) 38.

10/12/85 Ltr to US NRC from Detroit Edison re: Detroit Edison Response - SALP 6 Board Report No. 50-341/85027 (4 pages) 39.

10-11/85 Instrument Calibration Sheet (14 pages) 40.

11/04/85 Radiological Incidents & Deficiencies (17 pages) 41.

11/06/85 Administrators Guide for Health Physics Equipment (7 pages) 42.

11/11/85 Ltr to US NRC from Detroit Edison re: Transmittal of Licensee Event Report No. 85070 (6 pages) 43, 11/15/85 Calibration Data and Certification (3 pages) 44.

11/18/85 Preliminary Notification of Event or Unusual Occurrence PN0-III-85-98 (1 page) 45, 11/18/85 Daily Report re: release from condensate tank w/ handwritten notes (6 pages) 46.

11/19/85 Handwritten notes on condenser hot well (2 pages) 47.

11/26/85 Exposure Rate Verification Form (49 pages) 48, 11/27/85 Ltr to US NRC from Detroit Edison re: Additional Information Regarding the Reactor Operations Improvement Plan (8 pages) 49, 12/02/85 Daily Report re: circulation water discharge monitor found inoperable w/ notes (4 pages) l 50, 12/13/85 Fermi 2 Procedure - Radio Chemistry - Special Tests (14 pages) 51.

12/31/85 Ltr to US NRC from Detroit Edison re: Transmittal of Licensee Event Report No. 85080 (2 pages) i

52. Various dates Certificate of Conformance (10 pages)
53. 01/86 Detroit Edison Deviation / Event Report (11 pages)
54. 01/86 Waste Sample Tank Worksheet (7 pages)
55. 01/86 Liquid Effluents (13 pages) 3 i

l

(

Appendix A (cont'd)

F0IA 86-373

56. 01/15/86 Ltr to S. Bartman from R. Andersen re:

radiation alarm / trip setpoints (5 pages)

57. 01/16/86 Ltr to US NRC from Detroit Edison re:

Licensee Event Report No. 85080-01 (5 pages)

58. 01/16/86 IMEPS Inspection Plan (1 page)
59. 01/29/86 NotesonLERevents(2pages)
60. 02/07/86 Fermi 2 Procedure - Health Physics - Surveying and Analysis, Revision 10 (13 pages)
61. 02/21/86 Instrument Calibration Sheets (15 pages)
62. 3/86 Instrument Calibration Sheets (15 pages)
63. 03/06/86 P0M Procedure Change Request (4 pages)
64. 03/12/86 Ltr to J. Keppler from F. Agosti re:

Startup Report w/ copy of the Detroit Edison Company, Fenni 2, Nuclear Power Plant Interim Startup Test Report (96 pages)

65. Undated Detroit Edison Company, Enrico Fermi Atomic Power Plant - Unit 2, Administrator's Guide for Healthy Physics Equipment - Calibration (11 pages)
66. 04/18/86 Detroit Edison Organization Charts (2 pages)
67. 04/21/86 NRC Inspector's Entrance Meeting sign-in sheet (2 pages)
68. 04/24/86 Ltr to R. Eberhardt from H. Higgins re:

Radioactive Material Accountability (48 pages)

69. 05/07/86 Da11y Report re: accusations about plant radiation protection group (1 page)
70. 05/07/86 Memo to C. Weil from L. Hueter re: Notification by Licensee (Fermi 2) of Allegations to Press by Safe Energy Coalition Regarding Plant radiation Protection Program (1 page)
71. Undated Table 1 - Evaluation Criteria With Attributes for Assessment of Licensee Performance (4 pages)
72. Undated Systematic Assessment of Licensee Performance (2 pages)

J 4

... ~.. -

s I

t Appendix A (cont'd)

F0IA 86-373

73. Undated Gaseous Effluents (6 pages) 74.

Undated ContainmentSystems(3pages)

75. Undated Radioactive Effluents (1 page) i I

5 l

3 - -

\\

Appendix B F0IA 86-373 Documents Already Available in the PDR 1.

03/01/84 Inspection Report No. 50-341/84-03 PDR ADOCK 05000341Q 840301 8403190309A 2.

05/09/84 Inspection Report No. 50-341/84-12 PDR AD0CK 05000341Q 840509 8405240027A 3.

08/10/84 Inspection Report No. 50-341/84-27 PDR A00CK 05000341Q 840810 8408270084A 4.

12/26/84 SALP Report No. 50-341/84-23; 50-341/84-23-01 PDR ADOCK 050003410/F 841226 8412310322A PDR ADOCK 05000341Q/F 850320 8503260540A 5.

01/11/85 Inspection Report No. 50-341/84-43 PDR ADOCK 05000341Q 850111 8502040142A 6.

04/01/85 Inspection Report No. 50-341/85017 PDR ADOCK 05000341Q 850401 8504080368A 7.

06/28/85 SALP Report No. 50-341/85027; 50-341/85027-01 PDR ADOCK 050003410/F 850628 8507120333A PDR AD0CK 05000341Q/F 850911 8509160370A 8.

07/29/85 Inspection Report No. 50-341/85029 PDR AD0CK 05000341Q/F 850729 8508020002A PDR AD0CK 05000341Q 851004 8510100150A 9.

02/12/86 Inspection Report No. 50-341/86002 PDR ADOCK 05000341Q 860212 8602190039A NRC LE 05000341 850603 860212 NRC LE 05000341 851011 860212 l

l l

6 Appendix C F0IA 86-373 Documents Being liithheld in Their Entirety 1.

Undated Inspection Notes (5 pages) - Exemption 5 2.

04/03/86 Memo to J. Hind from C. Weil re: Allegations re: Radiation Protection at Fermi 1 and 2 (50-16; 50-341)(AMS No. RIII-86-A-0053) w/ Allegation Data Input form (5 pages) - Exemption 5 3.

05/12/86 Inspector's handwritten notes (12 pages) -

Exemption 5 4.

05/28/86 Memo to E. G. Greenman from J. A. Hind re:

Allegation re:

Fermi Radiation Protection Program (50-341)(AMS No. RIII-86-A-0083)

(1 page) - Exemption 7A v

4 1

4 i

I

a Appendix D F0IA 86-373 Documents Being Withheld in Part 1.

Undated Trainee Inquiry - Program Status (24 pages) -

Exemption 6 2.

Various dates Resumes (119 pages) - Exemption 6 3.

04/03/86 Memo to J. A. Hind from C. H. Weil re: Allegations re: Radiation Protection at Fermi 1 and 2 (50-16; 50-341) (AMS No. RIII-86-A-0053) (2 copies -

one with attachment, one without) (9 pages) -

Exemptions 6 & 7A 4.

05/02/86 Ltr to Detroit Edison re: whole body count (1 page) -

Exemption 6 e

I

GOVERNMENT ACCOUNTABILITY PROJECT 1555 Connecticut Awnue, N.W., Suite 202 Washington, D.C. 20036 (202)232-8550 July 16, 1986 APPEAL DE INITIAL FDIA DEM Victor Stello Executive Director for Operations

[ h -jQ / g q g U.S. Nuclear Regulatory Commission h7 g, Washington, D.C.

20555 Re:

Appeal of FOIA 86-373

Dear Mr. Stello:

This is an appeal pursuant to subsection a(6) of the Freedom of Information Act as amended (5 U.S.C.

522), of the effective denial of the Commission to release documents requested on May 16, 1986, by the Government Accountability Project.

No response from your agency has been received in this matter since a May 29,1986 form letter acknowledging receipt of the request.

We expect your response to this appeal within 20 working days of your receipt so that we can determine whether to pursue this matter further in the courts.

Thank you for your consideration of this matter.

Sincerely, B a A L C. A Billie Pirner Garde Director, Environmental Whistleblower Clinic

/sls J1 io A. > ~

7-j f

kh'

,