s q,

m 6

Ducomber 13, 1985 MEMORANDUM FOR: _

-t.. F. Wen,ter man Y -

F ROM a '

~ W. F.

Smith

SUBJECT:

~

TUEC'S 9/30/85 RESPONSE'.TI) NRC STAFF EVALUATION OF CPSES RESPONSE TEAN PROGRAM PLAN AND ISSUE-SPECIFIC' ACTION PLANS (ISAP)

I have reviewed subj ect response. in t he section pertaining to -

ISAP'Section III.a.1, " Hot Functional Testi ng (HFT) Data Packages" and have found a f ew problems as i den ti f i ed bel ow.

7 TEM 1:

. Inconsistency between SSER-7 action required and IGAP.

the t he r cropons.e imp 3les that a _ gett;p,nd.ampl e et.of 20 test data. packages have beets evaluated. Based on my followup innpection,.this was, not donu, and understandably not, berausa.w described in 4.1.8 of ISAP III.a.1 reject was not identified in the first e

sample ' set. - Al so the response describes two 60-item sample sets of TPDs and TDRs to be evaluated, with one sample set coming from a population of 820 TPDs and the other from 323 TDRs. During the NRC followup i nspecti on, I found only one sample set of 60 items which was. drawn from a total populat2on consisting of 820 TPDs, plus 323 TDRS, plus 254 FSAR-test method commitmentu. There was not a sr#cond sample set, and ninco no r oj c r ts c..wmn out

<>f t he ' f i est 60-item sampio cet, t lierr e di d not appeat-tu t.e o ner'd for un t'.

Thi s r er.panse should ha clar 2 4 t ed to r eflect what was actuall y dnne, and if addit 3cnal enemi tments ar e being made, it should so stata.

ITEM 2:

Inconnistency between sectioris 3.0 and 4.0 of ISAP No.

111.a.1.

The response to Item 2 appears to have a typo err or.

One "4.0" should be a "3.O.

I have discussed the above with R.

Kei mi g, TRT Group Leader for t he Test. Pr ograms, and he concurs.

.dk Ward F. Smsth. RRI i

8612110074 861204 i

PDR FOIA GARDE 86-272 PDR

.