Dacembzr 1, 1986 AMENDMENT NO.-5(Tr0 FACILITY OPERATING LICENSE NO. DPR Sequoyah Nuclear Plant linit 1 AMENDMENT NO.'k0 FACILITY OPERATING LICENSE NO. 'DPR Sequoydh Nuclear Plant Unit 2

.DISTRIBilTION w/ enclosures:

' Docket 150.:. <50-327/328. "'#.

4 NRC PDR Local PDR NSIC PRC System PD#4 Reading File C. Stable M. Duncan OGC-Reth R. Diggs, ADM T. Barnhart (8)

E.L. Jordan, DEQA:IAE -

L.J. Harmon, I&E B.J. Youngblood J. Holonich N. Thompson E. Butcher W. Jones H. Denton.

J. Taylor G. Zech, RII B. Hayes K. Barr. RII E. Fields, EICSR H. Thompson, Jr.

M. Reinhart, AR fM200300861201 p

DOCK 05000327 PDR

.,- ---... -.~,.-,..., -

/

o UNITED STATES 8.

NUCLEAR REGULATORY COMMISSION o

B

.,i WASHINGTON, D. C. 20555 g

g

    • e,.<*

TENNESSEE VALLEY AUTHORITY DOCKET NO.

50-327 SE000YAH NUCLEAR PLANT, UNIT 1 AMEN 0 MENT TO FACILITY OPERATING LICENSE Amendment No. 50 License No. DPR-77 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment to the Sequoyah Nuclear Plant, linit 1 (the facility) Facility Operating License No. DPR-77 filed by the Tennessee Valley Authority (licensee), dated August 8,1986, complies with the standards and requirements of the Atomic Energy Act of 1054, as amended (the Act) and the Commission's regulations as set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the license, as amended, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 o' the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is hereby amended by page changes to the Appendix A Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facilf tv Operating License No. DPR 77 is hereby amended to read as follows:

r i

1 n

,em

,--.-.n.n,-->-~,a-

-w,.-

-s.--

+ ~--- -------- --- -

y

~

I t 1

_g_

(2)'TechnicalSpecifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 50 are hereby incorporated into the license. The licensee shall operate the facility in accordance with the Technical: Specifications.

3.

This license amen 6nent is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY COMISSION

\\V B. J. Youngbinod, Director PWR Pro.fect Directorate #4 Division of PWR Licensing-A Attachment" Appendix A~ Technical Specification Changes Date of Issuance: December 1, 1986

/

l PK WR-A PW WR-A PWR PWR-A OGC/R BJM)e PW3 WR-A i

MD mac J

ich cst M

g food 11/1 /86 11 86 11/ /86 11/d/86 11/-)

86

'~

\\ \\ ebb ECR/dPWRA'

/

j BKSingh 11/iq/86 4

ATTACHMENT TO LICENSE Al;El;CI'ENT N0. 50 S

'O FACILITY OPERATING LICENSE NO. DPR-77 DOCKET I;0. 50-327 Foplace the following page of the Appendix "A" Technical Specifications with tFe enclosed page.

The revised page is identified by Amendment number and contains vertical lines indicating the areas of chance.

Ar.1 ended Page 3/4 5-8 9

r

_~

EMERGENCY CORE COOLING SYSTEMS (ECCS) o SURVEILLANCE REQUIREMENTS (Continued) h.

By performing a flow balance test during shutdown following completion of modifications to the ECCS subsystem that alter the subsystem flow characteristics and verifying the following flow rates:

1.

For safety injection pump lines with a single pump running:

The sum of the injection line flow rates, excluding the a.

highest flow rate is greater than or equal to 444 gpm, and l b.

The total pump flow rate is less than or equal to 675 gpm. l 2.

For centrifugal charging pump lines with a single pump running:

The sum of the injection line flow rates, excluding the a.

highest flow rate is greater than or equal to 316 gpm, and l b.

The total pump flow rate is less than or equal to 555 gpm.

3.

For all four cold leg injection lines with a single RHR pump running a flow rate greater than or equal to 3976 gpm.

SEQUOYAH - UNIT 1 3/4 5-8 Amendment No.

50

jo, UNITED STATES y

',g NUCLEAR REGULATORY COMMISSION 7,

E WASHINGTON, D. C. 20555 TENNESSEE VALLEY AIRHORITY DOCKET NO.

50-328 SE0lf0YAH NifCLEAR PLANT, llNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 42 License No. DPR-79 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment to the Sequoyah Nuclear Plant, linit 2 (the facility) Facility Operating License No. DPR-79 filed by the Tennessee Valley Authority (licensee), dated August 8,1986, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Comission's regulations as set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the license, as amended, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and

~

safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuarce of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is hereby amended by page changes to the Appendix A Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-79 is hereby amended to read as follows:

l t

-?-

(2) Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 42 are hereby incorporated into the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY CO M ISSION

\\S B. J. Youngblood, Director PWR Pro,iect Directorate #4 Division of PWR Licensing-A Attachment Appendix A Technical Specification Changes Date of Issuance: December 1, 1986 PWR R-A PWR.

WR-A PW

/DPWR-A OG TH PW f

R-A MDb ac J

n ch CStAhle 2-BJYou lood 11/f /86 114 86 11/g//86 11/p//86 11/

86

\\,d-O

\\

ECR/DPWR-A' RKSingh 11/13 /86

ATTACHMENT TO LICEf4SE Af;ENOMENT NO. 42 FACILITY OPERATIhG LICENSE NO. DPR-79 00CKET NO. 50-328 Replace the following page of the Arrcrdix t," Technical Specificetiens viith the enclosed page.

The revised page is identified by Amendment number and contains vertical lines indicating the areas of change.

/cended Page 3/4 5-8 i

L

l EMERGENCY CORE COOLING SYSTEMS g

SURVEILLANCE REQUIREMENTS (Continued) h.

By performing a flow balance test during shutdown following completion of modifications to the ECCS subsystem that alter the subsystem flow characteristics and verifying the following flow rates:

1.

For safety injection pump lines with a single pump running:

a.

The sum of the injection line flow rates, excluding the highest flow rate is greater than or equal to 444 gpm, and l

b.

The total pump flow rate is less than or equal to 675 gpm.

l 2.

For centrifugal charging pump lines with a single pump running:

a.

The sum of the injection line flow rates, excluding the highest flow rate is greater than or equal to 316 gpm, and b.

The total pump flow rate is less than or equal to 555 gpm.

3.

For all four cold leg injection lines with a single RHR pump running a flow rate greater than or equal to 3976 gpm.

l l

l SEQUOYAH - UNIT 2 3/4 5-8 Amendment No. 42 I

..