_
NUCLEAR REGULATORY COMMISSION p
g' UNITED STATES t
wAsmwaTou, o. c. ams Decamber 2, 1986 Docket No. 999001068/86-01 Wilmar Electronics ATTN:
Zev Helfetz General Panager 2430 Amsler Street Torrance, California 90505 Gentlemen:
This refers to the inspection conducted by Mr. Jeff Jacobson of this office on October 15-16, 1986, of your facility at Torrance, California and to the discussions of our findings with you and members of your staff at the conclusion of the inspection.
This inspection was made as a result of a 10 CFR Part 21 report to the NRC by Sacramento Municipal Utility District concerning relays supplied by Wilmar for use at the Rancho Seco Nuclear Power Plant.
During the inspection, it was determined that the relays reported by Sacramento Municipal Utility District as being defective had surpassed their intended design life. Also, various design changes and part replacements had occurred since the relays original delivery in 1972.
In accordance with 10 CFR 2.790 of the Comission's regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.
Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
o ert F. Heishman, Chief Vendor Program Branch Division of Quality Assurance, Vendor and Technical Training Center Programs Office of Inspection and Enforcement
Enclosure:
Inspection Report No. 99901068/86-01 cc w/ enclosure:
Sacramento Municipal Utility District ATTN: Mr. J. E. Ward ( Acting)
Assistant General Panager, Nuc1 car 6201 S Street, Post Office Box 15830 go9 Sacramento, California 95813 lJ/
\\
guaoggg;gggga Y
99901068
d Wilmar Electronics December 2, 1986 DISTR"BilT10N:
]
.DQAVT Reading RStarostecki BGrimes HMiller RHeishman EMerschoff JStone JJacobson LParker Sr. Resident Inspector (Rancho Seco)
VPG:00AVT.
5 Jr VT BC/VPB:00AVT JJacobsontsam E
lRf RHSishman 11/IV/06 1
M 6
)
j.1,