_

q

.d ATTACHMENT 2 s

EFFECTIVE DATE 02-18-87 L

E.01

"** 2 O

IMMEDIAT3 ACTIONS 1

9

..D 1

e l

O B7061co285 870602 Rev. 1 PDR ADOCK 0500 2

E.01-1 u

j

=_

>-]

-i 1

l O

IMMEDIATE ACTIONS DETERMINE WHETHER THIS IS A REACTOR TRIP OR A SGTR SHUTDOWN SITUATION AND PROCEED BELOW.

SGTR HAS OCCURRED AND THE REACTOR HAS-F_QT TRIPPED (GUIDEllNE NO. 4)

GO TO "SGTR" E.06.

.,. =O REACTOR TRIP HAS OCCURRED _QE SHOULD HAVE OCCURRED

1. MANUALLY TRIP THE REACTOR.

i

.1 IE the Reactor has HQI tripped hnmediately Go to E.02, step 1.

2. MANUALLY TRIP THE TURBINE.
3. REDUCE. LETDOWN TO ~ 40 GPM.
4. GO TO " VITAL SYSTEM STATUS VERIFICATION" E.02 hv. 1 E.01-3 I

L

'