Forwards Insp Rept 70-1100/87-01 on 870413-16 & Notice of Violation.Program Weaknesses Brought to Attention During Previous Insps Remained Uncorrected.Weaknesses Involved Lack of Certain Radiological Protection Procedures
ML20214S452
Person / Time
Site: 07001100
Issue date: 05/26/1987
From: Martin T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Lichtenberger
ABB COMBUSTION ENGINEERING NUCLEAR FUEL (FORMERLY
Shared Package
ML20214S455 List:
References
NUDOCS 8706090274
Download: ML20214S452 (2)


Text

_

MAY 2 6 1987 Docket No: 70-1100 License No. SNM-1067 Combustion Engineering, Inc.

ATTN: Mr. H. V. Lichtenberger Vice President - Nuclear Fuel Nuclear Power Systems - Manufacturing P. O. Box 500 Windsor, Connecticut 06095 Gentlemen:

Subject:

Inspection Report No. 70-1100/87-01 A routine, unannounced inspection was conducted on April 13-16, 1987 by Ms. Jean Cioffi and Mr. Robert Loesch of the Combustion Engineering Nuclear Manufacturing building and the Nuclear Laboratories used under Special Nuclear Materials License No.1067. Areas inspected included the implementation of radiological controls with respect to operations in the plant and laburatories, effluent and environmental monitoring, and transportation activities. The details of the inspection appear in the enclosed inspection report.

Our inspector noted that program weaknesses brought to your attention during previous inspections remained uncorrected. These weaknesses involved the lack of certain radiological protection procedures and-radiological protec-tion instrument calibration problems which were previously identified in NRC Inspection Reports No. 70-1100/85-01 and 70-1100/86-03, respectively. We are concerned with the lack of management attention and action in resolving these previously identified radiological control weaknesses.

Within the scope of this review, five apparent violations were identified.

~

Details of the violations are provided in the enclosed Appendix A.

You are required to respond to these findings by following the instructions included in Appendix A.

The responses directed by this letter and the accompanying Notice are not subject to the clearance procedures of the Office of Management and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.

t Your cooperation with us in this matter is appreciated.

Sincerely, Original Si""ed F11 M

(

8706090274 870526 A g

omas T. Martin, Director PDR ADOCK 07001100 U

Division of Radiation Safety C

PDR and Safeguards l

t l

l OFFICIAL RECORD COPY IR CE 87 0001.0.0 05/16/87 W

..U t

Comburtion Engineering, Inc.

2

Enclosures:

1.

Appendix A, Notice of Violation'

.2.

NRC Region I Inspection Report No. 70-1100/87-01 cc:

Public Document Room (PDR)

Local Public Document Room (LPOR)

Nuclear Safety Information Center (NSIC)

State of Connecticut bec w/ enc 1:

Region I Docket Room (with concurrences)

Management Assistant, DRMA (w/o encl)

Robert J. Bores, DRSS J. Roth, DRSS S. Soong, NMSS RI:DRSS RI:DRSS RI:DRSS RI:DRSS SS p Cioffi/ms Loesch Shanbaky Bellamy Ma in v

Dnl (NK, 5/2f/87 5/18/87 5/22/87 5/J'787 5/ /

OFFICIAL RECORD COPY IR CE 87 0002.0.0 05/16/87