ML20214Q837

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 870425-0518
ML20214Q837
Person / Time
Site: LaSalle  Constellation icon.png
Issue date: 05/29/1987
From: Forney W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20214Q828 List:
References
50-373-87-16, 50-374-87-16, NUDOCS 8706050221
Download: ML20214Q837 (1)


Text

.

NOTICE OF VIOLATION Commonwealth Edison Company Docket No. 50-373 i

As a result of the inspection conducted on April 25, 1987, through May 18, 1987, and in accordance with 10 CFR Part 2, Appendix C - General Statement of Policy and Procedure for NRC Enforcement Actions (1985), the following violation was identified:

Technical Specification Surveillance Requirement 4.1.3.1.2a states that when above twenty percent power, all withdrawn control rods shall be demonstrated operable by moving each control rod at least one notch at least once per seven days.

Contrary to the above, between March 27, 1987, and April 10, 1987, control rods 6-39, 14-15, 14-31, 14-47, 18-19, 18-43, 22-07, 22-23, 22-31, 22-39 and 22-55 were not demonstrated operable by moving each control rod at least one notch at least once per seven days.

This is a Severity Level IV violation (Supplement I).

Pursuant to the provisions of 10 CFR 2.201, you are required to submit to this office within thirty days of the date of this Notice a written statement or explanation in reply, including for each violation: (1) corrective action taken and the results achieved; (2) corrective action to be taken to avoid further violations; and (3) the date when full compliance will be achieved.

Consideration may be given to extending your response time for good cause shown.

MY 2 9 G87 69 C Y;r&

Dated W. L. Forney, Chief '

Reactor Projects Branch 1 l

l I

8706050221 870529 PDR ADOCK 05000373 PDR G