ML20214Q081

From kanterella
Jump to navigation Jump to search
Expresses Concerns Re Several Apparent Breaches of Normal Operating Procedures by Plant Employees.Response Discussing Measures Underway to Ensure That Flaws Addressed & Sufficiency of Mgt Oversight Requested.Related Encls
ML20214Q081
Person / Time
Site: Peach Bottom  
Issue date: 10/29/1986
From: Walker R
HOUSE OF REP.
To: Zech L
NRC COMMISSION (OCM)
Shared Package
ML20214Q054 List:
References
NUDOCS 8612040508
Download: ML20214Q081 (4)


Text

y ROBERT S. WALKER.

swr us cuam

,,p.._m_.__

==

MARC T. PHILUPS

,,:l"',l, l"::,

Congit%% of tfje 1Rnittb blatt6

      • "c" Dottge of Representatibes Masfjington, B.C. 20515 October 29,1986 Mr. Lando W. Zech, Jr.

Chairman Nuclear Regulatory Commission 1717 H Street, N.W.

Washington,D.C. 20555

Dear Mr.Zech:

I am writing to express my concern about recent press reports highlighting apparent problems at the Peach Bottom nuclear plant located in York County, Pennsylvania. These reports appeared in the Lancaster Sunday News.which is the largest Sunday newspaper in my district.

The paper's articles outline several general areas of concern.

There apparently have been several breaches of normal operating procedures by employees at the plant. These incidents, it is noted, may be the result of

~ faulty traininir and/or a lack of effective, diligent oversight by management.

Obviously I am greatly concerned about these allegations, especially representing the district that neighbors Three Mile Island, as I do. We learned a lot from that experience. The most enduring lesson is that the management of a nuclear power generating facility has the highest degree of responsibility to the community it serves to ensure that the operations of the plant are being operated in ac::ordance with the strictest security safeguards so that public confidence in the safety of the plant is maintained.

To proceed otherwise, or even to leave doubts or unanswered questions in the minds of nearby residents, creates an atmosphere of mistrust and insecurity.

The psychology of a situation like that can easily get out of hand. It is in the best interests of everyone to not even get close to a situation in which the community has any cause to lose confidence in the safe operation of a nuclear power facility.

As such, I would appreciate your review and comments on the situation. In particular, I would like to know what measures are being taken to ensure that these flaws are being addressed.

In your opinion, are employee training programs at the plant sufficient? Or is there more that can and g2040508861124 ADOCK 0500o177 p

PDR

,g,.

~~

should be done? Also, is it your opinion that management is conducting diligent, thorough oversight to ensure beyond reproach that strict safeguards are understood and are being followed? What corrective steps are being taken, or will be taken, if management oversight is insufficient?

I would be very appreciative for your expeditious response to these questions, as well as your providing me with any other information of which you are aware that may be relevant to the safety procedures at the Peach Bottom plant. Thank you very much.

Cor ially, Rob S. Walker I

h

i.. *L-

,l

. A i

anaro:

-/

'o,,

UNITED STATES jQh'

! T' NUCLEAR REGULATORY COMMISSION 1e

-- s ' \\

,E

' 7,.

ileg]

o.

WASHINGTON, D. C. 20555 F

[

EDO PRINCIPAL CORRESPONDENCE CONTROL

/1 FROM:

DUE4 11/4 d86 EDO CONTROL: 002279 DOC DT: '10/29/86 REP.. ROBERT S.

WALKER FINAL REPLY:

TO:

CH' AIRMAN ZECH FOR SIGNATURE OF:

    • PRIORITY **-

SECY NO: 861151 EXECUTIVE DIRECTOR DESC:

ROUTING:

REQUEST INFO ON POSSIBLE SAFETY PROBl. EMS AT DENTON PEACH BOTTOM TAYLOR DATE: 11/03/86 ASSIGNED TO: RI CONTACT: MURLEY SPECIAL INSTRUCTIONS OR REMARKS:

i l

l l

1

.=

,s OFFICE OF THE SECRETARY CORRESPONDENCE CONTROL TICKET

. PAPER NUMBER:.

CRC-86-ll51 LOGGING DATE:.Oct 31 86 ACTION OFFICE:

EDO AUTHOR:

R.S. Walker AFFILIATION:

U.S. HOUSE OF REPRESENTATIVES LETTER DATE:

Oct 29 86 FILE CODE:

SUBJECT:

Requests information on possible safety problems at Peach Bottom ACTION:

Signature of EDO DISTRIBUTION:

RF, OCA to Ack.

SPECIAL HANDLING:

NOTES:

DATE DUE:

Nov 17 86 SIGNATURE:

DATE SIGNED:

AFFILIATION:

Rec'd Off. EDO I' '

'5Y Date.

Time h 6g l

EDO - 002279 l

.