WESTlNGHOUSE CLASS 3 WCAP 10930 Revision 1 TOUGHNESS CRITERIA FOR THERMALLY AGED CAST STAINLESS STEEL Prepared by:

F. J. Witt C. C. Kim Reviewed by:

S. A. Swamy September 1985 Revision 1: July 1986 APPROVED:

/ M APPROVED:

  1. ' ' ~" " =
5. 5. Palusamy, Manager D. C. Adamonis, Manager Structural Materials NDE & Welding Engineering Engineering 8609240076 860910 WESTINGHOUSE ELECTRIC CORPORATION PDR ADOCK 05000282 NUCLEAR ENERGY SYSTEMS P

PDR P.O. Box 355 Pittsburgh, Pennsylvania 15230 7-

e i

FOREWORD

~

The original version of this report was dated September 1985. Since that time, the Nuclear Regulatory Commission has reviewed the report and made recommendations. New experimental thermal aging data have also become available. Revision 1 is an updated version of the original report. It addresses comments and recov;endations including those from the Nuclear Regulatory Commission and fncorporates newly acquired data on the effect of thermal aging on fractt:re toughness. The revisions are identified by vertical lines in the column.

4 i-g e

4 l

t s

e iii

t TABLE OF CONTENTS

,P,ag Section Title a

1.0 INTRGDUCTION AND BACKGROUND 1-1 t

2.0 A GENERAL TOUGHNESS CRITERIA FOR THE THERMALLY AGED CAST STAINLESS STEEL - [

Ja.c.e 2-1 2.1 Introduction 2-1 2.2 Metallurgy of Thermally Aged Cast Stainless Steel 2-1 2.3 General Toughness Behavior of Thermally Aged Cast Stainless Steel 2-2 2.4 Energy Disposition in Impact Specimen Testing 2-8 2.5 Summary of the (

la.c.e Criteria - CIRCA 1984 2-11 2.6 Additional (

Ja.c.e Data 2-12 2.7 The KCU for (

la.c.e 2-36 2.8 Fracture Toughness for Fully Aged Cast Stainless Steel 2-37 h

2.9 Esperimental Verification for Fully Aged Toughness Determination 2-43 2.10 Uncertainty Evaluations in the Fracture Toughness Estimations 2-47 2.11 The Alternate Toughness Criteria 2-55 2.12 Sample Application of the Alternate Toughness Criteria 2-63 3.0 DISCUSSION AND CONCLUSIONS 3-1

4.0 REFERENCES

4-1 S

=

P v

b

i LIST OF FIGURES Figure Title g

2-1 Full impact curves for 6.4 mm (0.25 in.) Allegheny Ludlum-melted E-BRITE alloy laboratory-annealed and air-cooled or water-quenched 2-3 2-2 Charpy V-Notch Energy Curve for Various Aging Times -

Four Inch Pipe Material (The aging temperature was 800*F(427'C))

2-5 2-3 Effect of Aging Time on Charpy Impact Results 2-6 2-4 DVM impact transition curves showing the effect of longtime agjng at 280*C 2-7 2-Sa Fracturing Process of the Duplex Material 2-9 2-5b Ligaments of Duplex Structure Exhibiting Ductile Behavior 2-9 2-5c Sketch of Fracture Surface of Austenitic - Ferritic Impact Specimen with completely embrittled ferrite showing a tortuous fracture path for a beam 2-9 i

2-6a Dimensions on Swiss VSM and German DVM keyhole 2-14 specimens 2-6b Charpy (Simple-Beam) Impact Test Specimens, Types A, B and C (ASTM E-23) 2-14 2-7 Charpy U-Notch Energy at Room Temperature for [

Ja c.e 2-15 2-8 Charpy V-Notch Energy at Room Temperature and 550*F for [

Ja.c.e 2-16 2-9 J-integral Results at 600*F for [

]a,c.e, B = 0.34 in. (Based on Deformation J Evaluation) 2-17 2-10 J-integral Results at 200*F for (

la.c.e, B = 0.34 in. (Based on Deformation J Evaluation) 2-18 2-11 J-aa Curves at Different Temperatures for Aged Material

(

Ja.c.e 2-19 2-12 Full Size Plan View of Material Used in Investigation, Thickness was 0.772 in. (20 mm) 2-20 2-13 Load Time Trace for Charpy V-Notch Impact Specimen 78A of (

la.c.e Material Tested at Room Temperature 2-23 vii 1

LIST OF FIGURES Figure Title Page 2-14 Load-Displacement Curves for the.Five 0.394 in.

Thick Compact Specimens Tested at Temperatures Between -200'F and 550*F (Note differences in scales and crack ratics) 2-24 2-15 True-Stress True-Strain Curves at Rooin Temperature and 600'F for [ a.c.e J

2-28 2-16 Load-DisglgegmentCurvesfor0.34in.ThickSpecimensof

[

]

Material Tested Statically Between

-320*F and 600'F using Unicading Compliance _

2-29 2-17 J-Integral Results at -320'F for [

Ja.c.e (Based on Deformation J Evaluation) 2-30 2-18 J-Integral Results at Room Temperature (75'F) for

[

Ja,c,e-(Based on Deformation J Evaluation) 2-31 2-19 Comparison of Static Load-Displacement Curve with Dyna-mic Load-Displacement Curves at 600*F ((

])ac.e 2'-32 Je as a function of Test Temperature for (

3a.c.e 2-34 2-20 I

2-21 Variation of Tmat with Temperature for [

la.c.e 2-35 2-22 Correspondence Between the KCV Energy and KCU Energy of Austenitic Stainless Steels tested at 20'C 2-39 2-23 Micrographic features of two-phase specimens as a function of chemical composition Ni'eq/Cr'eq and thickness. The ferrite is colored by electrolytic etching in a 10-N sodium hydroxide solution. dF = average segment intercepted by ferrite (um); 6% = ferrite content 2-41 measured by micrography 2-24 Comparison of Experimental KCus with Calculated KCus for CF8M and CF8 Cast Stainless, Steels 2-49 2-25 Comparison of Experimental KCus with Calculated KCus for CF8M Cast Stainless Steel Only 2-50 2-26 Variation of J c with Charpy V-Notch Impact Energy 2-56 I

2-27 Plots of JIc, Tma.

and Jmax at Operating Temperature as a Function of f, 3a c.e 2-59 viii L

e t

LIST OF FIGURES (Cont)

Figure Title Page 2-29 Sketch for Determining Fracture Toughnesses from

'~

calculated KCU Values 2-62

~

2-29 Typical Layout of the Primary Loops for a Westinghouse Two-Loop Plant 2-67 2-30 Identification of Heats With Location for Cold Leg 2-68 2-31 Identification of Heats With Location for Hot leg 2-69

~

2-32 Identification of Heats With Location for Crossover leg 2-70

~

't l

l l

l l

~

\\

l iX l

9

+

',6' t

LIST OF TABLES Table Title Pa2' la,6, Chemistry and Material 2-1 Materials Specifications e

2-13 Properties of [

2-2 StaticFractureToughnessPropertiesfor(

la.c.

2-22 2-3 Charpy Impact Energies from Standard and Non-Standard Specimens at Different Temperatures for

[

la.c.e 2-27 2-45 2-4 Experimental Data For a Highly Aged Casting 2-5 Comparison of Predicted Fully Aged Toughness with the 2-46 Appropriate Experimental Data 2-6 Coefficients of Variation for the Chemical Elements used to Calculate the Ferrite Content in Cast Stainless 2-52 Steel atOperating]Tempgraturesfor 2-7 Jgg, Tmat and Jmax a,c, is known 2-58 which the [

2-8 Outline of Procedure For Establishing Fracture Toughness of a Heat of Thermally Aged Cast Stainless Steel 2-61 2-9 Example Chemistry and Calculated [

la,c.e Values 2-64 for Pipe and fittings 2-10 Fracture Toughness Criteria for the Primary Piping Components of the Example Two-Loop Plant for End-of-2-66 Service Life xi

~

t

1.0 INTRODUCTION AND BACKGROUND

It has been demonstrated by various ar.alyses conducted over the past several years that piping used in the primary systems of nuclear power plants will in general leak stably should large through-wall penetrations occur for the leads imposed (1.1,1.2,1.3)*

This demonstration has prompted both the nuclear power utilities and the Nuclear Regulatory Commi's'sion (NRC) to take advantage of this situation in the as-built design and construction of primary piping systems. Specifically, many of the utilities have prepared integrity evaluations on a plant specific basis which demonstrate that leak-before-break conditions exist for reasonably sized cracks when subjected to the applicable loadings. For Westinghouse type pressurized water reactors, most of the utilities have subcontracted to Westinghouse to develop the integrity evaluations. The evaluations have been used by the utilities as the technical basis for requesting exemptions from the NRC for installing plant specific pipe whip restraints and jet shields. The NRC has responded very favorably to the requests. Also they have revised General Design Criteria-4 to permit the use of advanced fracture mechanics analyses in lieu of postulated reactor coolant system main loop breaks (I*4).

The integrity evaluations rest mainly on the application of elastic-plastic fracture mechanics and leak calculation methodologies (1*I). One of the primary inputs to an evaluation is the elastic-plastic fracture criteria in which the calculated applied fracture toughnesses are compared against material fracture toughness values. In general, the J-integral approach has been applied with the criteria being(I*I) l l

l Superscripts refer to similarly numbered items in Section 4.0, References.

l l

1 '

d

w 1.

Japp < J c, or (1-1)

I J c, then Tapp < Tmat (1-2) 2.

If Japp 1 where Tmat is the tearing modulus and subscript app designates applied.

The NRC has addended these criteria by(1.5) 3.

Sufficient margin must be demonstrated (1-3) 4.

Japp < Jmax where Jmax does not exceed the maximum value of J determined from fracture toughness specimens.

Fracture toughness'J properties are in general not available for all cases for nuclear primary piping; however, Westinghouse has developed a bounding approach. Specifically, the criteria of Reference 1.6 has been used by Westinghouse in plant specific applications and has been reviewed by the NRC.(l*7) The approach generally divides the piping system into two categories:

(1) forged and (2) cast piping and welds. The analyses focus on the cast piping and fittings and welds since toughness degradation due to thermal aging is kncwn to occur for these two product forms, the cast material being limiting (1.6, 1.8). A correlation has been developed based on the chemistry of the cast material (

3a.c.e. Fortunately, a significant ar.ount of fracture toughness data has been generated on a highly sensitive heat of

}

cast stainless steel pipe identified as (

la.c.e. The KCU impact value was estimated to be [

la.c.e. Thus, any heat of pipe estimated to exhibit, at the 95%

confidence level", more than [

la.c.e; that is.

Jgg = [

Ja.c.e (14) uncertainty was not addressed in the original version of this report a

1-2

3

'C

(1-5) 8 Tmat = [

Jmax = (

]8'C

(1-6)

Of all the nearly 25 primary systems examined through the end of 1985, the l

applied loads were such that the above criteria were easily met with substantial margin being demonstrated. However;'the correlation based on chemistry does not produce the required energy for a limited number of heats of all the primary piping for some of the plants. In such a case where the

(

la.c.e energy can not be demonstrated at the 95%

confidence level, there is at present no explicit data base from which

~

component specific cr1teria may be obtained. Hence, the adequacy of calculated applied fracture toughness values cannot currently be quantitatively assessed using the above approach.

It is the objective of this report to develop alternate fracture toughness criteria for primary piping system components for any calculated [

la.c.e energy such that leak-before-break integrity evaluations may be performed.

Specifically, general toughness criteria for thermally aged cast stainless steel are developed for calculated (

la.c.e impact values which cannot be demonstrated to be as good as [

la,c.e. Uncertainty is addressed by requiring in general that toughness values be stated with a 95% lower confidence level. The incorporation of uncertainty considerations into the fracture toughness estimates is the primary difference between this Revision 1 and the original version.

l t

l 1-3 l

J

O 4

2.0 A GENERAL TOUGHNESS CRITERIA FOR THERMALLY AGED CAST STAINLESS STEEL -

[

ja.c.e

2.1 INTRODUCTION

The general background for this report has been discussed in the previous section. Inthissectionalternatefracturetouhhnesscriteriaareset forth. First the metallurgy of thermally aged cast stainless steel is reviewed. A general sumary of the toughness behavior of thermally aged i

stainless steel is provided. Impact test results are also provided and the nature of such results are explained. A summary of the [

la.c.e data is given supplemented by new results. Implications of impact energy to fracture toughness (J, K, T) are set forth. Finally alternate [

la c.e fracture criteria, taking uncertainty into consideration, are developed and supportive experimental data are set forth. A sample application is given.

The discussion of this chapter is strongly referenced to References 2.1, 2.2 and 2.3.

2.2 METALLURGY OF THERMALLY AGED CAST STAINLESS STEEL CF8A and CF8M type cast stainless steels in the primary loops of many Westinghouse type pressurized water reactors are two-phase alloys consisting of austenite and ferrite. The difference between CF8A and CF8M is that CF8M has molybdenum and CF8A does not. The ferrite content very seldom exceeds 25%

and the ferritic phase of these alloys has a chemical composition very similar topureferriticlowcarbonstainlesssteel(2.1),

It has been found that the chrome enriched ferrite of the two-phase alloys becomes hardened and embrittled when thermally aged at temperatures up to approximately 520*C (968'F). This embrittlement is caused mainly by the successive precipitation of chromium in ferrite due to the large miscibility gap in the Fe-Cr binary system. CF8A and CF8H type cast stainless steel in the primary loop system can experience the embrittlement after long time service because they are operated at temperatures generally from 550'F (288'C) to 600'F (316'C). The nature of this thermal aging has been 2-1

-+'--e t+mm-,-

ry, -.----sg.gg

.,,se.

.-y..

.,,.m,_..9-m

a extensivelyexplainedinaseriesofarticles(2.1through2.7).

These investigations were carried out on both pure ferritic alloys and ferritic-austenitic cast stainless steels.

References 2.4 and 2.7 investigated pure ferritic alloys and observed embrittlement effects on the alloys when thermally aged. The embrittlement was also observed in the ferrite phase of ferritic-austenitic duplex structure cast stainless steels by References 2.1 and 2.2.

Reference 2.2 concluded that the austenite matrix of the duplex structure cast stainless steels remains ductile while the ferrite phase shows cleavage rupture when the fractured surface of thermally aged Charpy impact specimens were examined. Based on these investigations it can be concluded that the ferrite phase of ferritice austenitic cast stainless steels becomes herder.ed and embrittled when thermally aged and behaves more or less as a ferritic stainless steel.

I l

2.3 GENERAL TOUGHNESS BEHAVIOR OF THERMALLY AGED CAST STAINLESS STEEL I

The fracture morphology of thermally aged cast stainless steel indicates that the hardened and embrittled ferrite behaves as a more or less ferritic stain-l less steel while the austenitic matrix is nonembrittling and continues to exhibit ductile behavior (2*I' 2 2). On this basis alone, a quantitative explanation should be forthcoming for the observed fracture toughness behavior of thermally aged cast stainless steel.

Ferritic stainless steels have been extensively investigated and an ASTM special technical publication has been devoted to the toughness of ferritic stainless steels (2.8). Examples of Charpy impact curves taken from f

Reference 2.8a are given in Figure 2-1.

It is seen that ferritic stainless steels exhibit a ductile-brittle transition very similar to low carbon l-steels. It is expected then that the ferritic phase of a thermally aged cast l

stainless steel is the primary' contributor to the loss of ductility as this phase becomes embrittled. Interestingly, no Kge, J e or Tmat results I

are presented Reference 2.8.

l 2-2 i

s

o e

M

=

t TEM PERATURE (*F )

-10 0

-50 0

50 10 0 15 0 200

  • WATER QUENCHED o AIR COOLED 2 71

- 200 15 0 203-1 a

O f

I

$a s

l U

b 100 $

136-k 50 68 l

~2 ft-lbs.

j 3

.e l

-73

-46

-18 10 38 65 93 TEMPERATURE (*C )

Figure 2-1 Full impact curves for 6.4 mm (0.25 in.) Allegheny Ludlum-melted E-BRITE alloy laboratory-annealed and air-cooled or water-quenched 2-3 l

t J

r-

~-

An example of loss of ductility due to thermal aging embrittlement and test.

temperature is given in Figure 2-2 taken from Reference 2.9.

The material is SA351 CF8M (Type 316). The aging temperature was 800'F (427'C). For the embrittlement time of 2000 hours0.0231 days <br />0.556 hours <br />0.00331 weeks <br />7.61e-4 months <br /> the upper Charpy V-notch energy is seen to drop by around 80 ft-lb down to approximately 100 ft-lb. The transition temperature is seen to increase by about 150'F. The major effect is seen to occur within the first 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> with perhaps a gradual lowering of the shelf with aging time thereafter. The transition behavior with aging time is l

not well defined in Figure 2-2.

An example of the expected transition j

behavior is shown in Figure 2-3 taken from References 2.9.

An example of the generic behavior was calculated 1.n Reference 2.1 and is shown in Figure 2-4.

It is thus concluded that the change in the Charpy V-notch (also U-notch) impact curves with thermal aging is a direct function of the ferrite hardening I

and embrittling. Indeed the embrittled effect on the ferrite is judged to be very similar to the effect of lower temperature embrittlement of ferritic stainless steel. Noting as in Figures 2-2 and 2-3 that the major embrittling effects occur in a relatively short time and appear to systematically saturate over much longer periods, ttiermal aging embrittlement of the ferrite-phase is entirely consistent with the rapid drop of Charpy energy in the transition temperature region of ferritic stainless steel followed by a much more gradual decrease in the lower shelf region (see Figure 2-1).

~

In Reference 2.1, 2.2, and 2.3, the austenitic matrix of the duplex structured l

l cast stainless steel is seen to remain ductile and nonembrittled. This austenitic matrix makes up from 75% to 85% by volume of the nuclear grade cast piping of interest. Austenitic stainless steel with little or no ferrite is very tough in terms of Charpy energy. For example, in Reference 2.1 Heat 291 contained 6% ferrite and exhibited over 150 ft-lbs (200J) impact energy prior to aging. The point here is that an aging embrittlement of roughly 20% of the material (the ferrite) produces very significant changes in the impact energy while around 80% of the material (the austenitic matrix) remains unembrittled and very ductile. Indeed the austenitic matrix must be a major contributor to Charpy values of around 150 ft-1bs in the unaged state; yet, it is unable to exhibit such toughness in the thermally aged state. This apparent anomaly is discussed in the next section.

2-4

a 4

)

TEMPERATURE ('C) 134 129 73.3 17.7 37.7 93.3 149 2*A 260 316 371 I

i i

i i

l l

l 260 o AS RECEIVED e 1200 HRS.

354 240 a 1000 HRS.

A 1500 HRS.

327 g h220 C 500 HRS.

E 2000 HRS.

299

{

5 200 272 m

180 O

h 245 E 150 217.7 E w

w 2 140 190.5 2 A 8 120 a-163.3

> 100 5%gC

- ^i

=.-

5-136.1 >

4

/

g g 30

/

103.3 g

$ s0 si.6 40 54.4 l

n a

n2 I

I 0

300 200 100 0

100 200 300 400 500 800 700 TEMPERATURE ('F) l 1

Figure 2-2: Charpy V-Notch Energy Curve for Various Aging Times-Four Inch Pipe Material (The aging temperature was 800'F(427'C)).

2-5 d

t

l 180 g

d LEGEND: TESTS DONE AT ROOM E

TEMPERATURE 160 O ENERGY-AXIAL ORIENTAT10N g

E 140

' ~

v LATERAL EXPANSION AXIAL g

ORIENTATION b 120 0 ENERGY-CIRCUMFERENTIAL ORIENTATION a

4 O LATERAL EXPANSION

@ 100 CIRCUMFERENTIAL ORIENTATION E

l 80 5

80 5.

W h

~N

~

l w

A T

.s g

g I

20 O 100 500 1000 2000 3000 4000 TIME (HOURS) AT 800*F (427*Cl l

Figure 2-3: Effect of Aging Time on Charpy Impact Results l

2-6 l

l

L

=

2-

  • HEAT 280N i

~'

E-9 c

f

/

i 5

i e

$5 4

.h hl

~

E

[$

I /

~

W y.-

/

  1. r U

f s%.

C a

3 Eb#f#'

I I

-33

-100 0

100 E3 300 400 TEST TEMPERATURE DEG.C Figure 2-4 DVM impact transition curves showing the effect of longtime aging at 280*C O

2-7 g

l l

0 j

2.4 ENEP.GY DISPOSITION IN IMPACT SPECIMEN TESTING t

In this section the above anomaly is discussed.

l For the unaged cast stainless steels at operating temperatures of interest the Charpy V-notch toughness in quite high, usually greater than 150 ft-lbs, oiten l

challenging the Charpy machine capacity of #250 ft-1bs. Ferritic l

stainless steels exhibit about the same Charpy toughness. Thus it is reasonable to assume that the contributions to the total energy by the austenitic matrix and the ferrite are approximately in proportion to the percent volumes of ea'ch components, perhaps 80% for the austenitic metrix and 20% for the ferrite. However, with aging the ferrite is embrittled and the.

l impact energy may dramatically decrease. The embrittled fracture behavior is depicted in Figure 2-Sa taken from Reference 2.2.

In Figure 2-5b, sketched to the right, the width (i.e., line of fracture) of the cross section consisting of the austenitic matrix is seen to be about 60% of the total cross sectional width. In general one might expect the austenitic matrix length to be around perhaps 80% of the total cross sectional width. Naturally, one would expect some reduction in.Charpy energy.if one assumes the ferrite makes little or no contribution to the fracture resistance. However, one might be surprised to observe around an order of magnitude reduction of Charpy energy when only 20%

of the material has been embrittled. This behavior is explained below.

Some years ago a rather intensive study was made of the energy disposition for various size impact specimens (2.10). A model was developed and verified f

which accounts for both the specimen width and depth when an impact test is made.

l For the problem at hand, the ferrite is assumed to make no contribution to the measured energy and the austenitic matrix is assumed to be fully ductile.

Under this assumption the basic equation for a single beam from Reference 2.10 becomes:

Et=A[BdW (2-1) 2 2-8 i

l

o V

f oup AN

~

~

.a...,...

  • r f

P l

I(1)

,, T 1(2)

. (3) r l

J(4) s Figure 2-Sa: Fracturing Process of the Figure 2-5b: Ligaments of Duplex Structure Duplex Material Exhibiting Ductile Behavior Direction of Loading i

Austentte y

/

h-rerrite 5

i o.;,._

f g,V

'"J. :"""

s a fL%.

.e-Figure 2-Sc Sketch of Fracture Surface of Austenitic - Ferritic Impact Specimen with completely embrittled ferrite showing a tortuous fracture path for a beam 2-9 b

o where Et is the total fracture energy, A is a material constant, W is the length of the fracture surface and B is the width of.the beam and is a' function of W.

For computational purposes, Equation (2-1) may be expressed in the sumation form k

Et*AI 8 W (2-2) i i=1 where k is the number of increments into which W is divided. For a set of individual beams of the same material, the total energy, E, is given by T

m k

2 (2-3)

ET=A I IB W) 93 9

j=1 i=1 where m is the number of individual strands (beams). For the austenitic

~

matrix in Figure 2-5b', m is 4 at the location observed.

In Figure 2-5b, the expected impact energy for the four ligaments of the

~

austenitic matrix, assuming they are distinct beams, is only about 25% of that j

had the ligament been as one. Of course the austenite is certainly not expected to be aligned into separate straight beams. However, a fracture surface in which there are originally voids (in this case the embrittled ferrite) would tear as beams with varying thicknesses with the cross constraints defined by the voids determining the actual distinct lines of material separation; hence the fracture surface is indeed representable by a series of beams. An example of the more or less random dispersion model for the ferrite is shown in Figure 2-5c. This cross section has separated as a series of beams of varying depths and widths; thus Equation (2-3) could be used to estimate the impact energy to fracture the specimen if the exact paths were known. An example of a fracture path for a beam is also sketched in l

~

2-10

Figure 2-Sc. For later discussion, such fracture paths will be called tortuous fracture oaths and the model representing the total fracture energy as given by Equation (2-3) is designated the tortuous beam model. For general applications the tortuous fracture paths can only be determined by microscopic examination of the fracture surface and could be highly subjective. This is not a problem for the applications made later of.the tortuous beam model.

Since unaged Charpy V-notch energies of at least 100 ft-lbs are expected and energies of around 20 ft-1bs have been measured on thermally aged st'ainless steel (2.3), one might inquire somewhat of the disposition of ligaments in the austenitic matrix to produce an energy perhaps representative of fully aged stainless steel. An energy of 10 ft-lbs will be used. The austenitic matrix is taken as 80% of the material. Equal width straight beams are assumed since nothing is known of the tortuous fracture paths. Solving Equation 2-3 by trial and error gives 7 ligaments each of width 0.045 in, to produce an energy of 10 ft-lb, assuming the unaged impact energy is 100 ft-lb.

The objective of this section was to demonstrate that the low Charpy energies measured from highly thermally aged cast stainless steel with a duplex structure of austenitic and ferrite is consistent with the metallurgically

~

observed ductile austenitic matrix with embrittled ferrite accounting for about 1/5 of the material by volume.

A complementary objective is to define an energy model for impact testing. It is judged that this objective has been successfully accomplished.

At this time one may inquire if static results would be the same as those observed for impact results. This question is answered in the affirmative in a later section.

2.5

SUMMARY

OF THE [

la.c.e CRITERIA - CIRCA 1984 Reference 2.3 provides much of e available information upon which the

[

la,c.e criteria previously discussed are based. In this section the

~

data is again presented for completeness and to provide background for the new data presented in the next section.

2-11 w

, - - - ~ - - - -,,

t First however, since the correlation of Reference 2.2 relates to Charpy U-notch (KCU) data, a more specific definition of the specimens tested is needed. Figure 2-6a taken from Reference 2.1, shows the two types of specimens tested in Reference 2.1.

The standard specimens of ASTM E-23(2.11) are shown in Figure

~

2-6b.

In this figure the Type A specimen is the standard Charpy V-notch (KCV) specimen. Note that the specimens of Figure 2-6a,have a different flaw depth than the Type C specimen of Figure 2-6b. The KCU data presented in Reference 2.2 are from the Type C specimen of Figure 2-6b.

In Reference 2.1, results from the VSM and DVM specimens shown in Figure 2-6a are used interchangeably even though I

the notches have different depths. In general the diversity of Charpy impact specimens tested increases the data scatter.

i

[

3a c.e The material specification, chemistry and material properties are given in Table 2-1.

The material corresponds to ASME SA351-CF8M. Room temperature Charpy U-notch data (Type C specimen of ASTM E-23) l are provided in Figure 2-7 as a function of aging time. Charpy"V-notch data obtained by Westinghouse (2 3) are given in Figure 2-8.

Fracture toughness J-R data obtained by Westinghouse are given in Figures.2-9 and 2-10 at 600*F and 200*F respectively. A summary of fracture toughness J-R data obtained from Reference 2.2 and Westinghouse (2-3) is given in Figure 2-11. The above results were used to establish the [

3a,c.e for operating temperatures as given by Equations (1-4), (1-5) and (1-6).

2.6 ADDITIONAL [

Ja.c.e DATA l

For the fracture toughness test on [

3a.c.e performed by Westinghouse only one half of a non-standard 2T compact specimen (2*I2) (B = 0.772 in. 20 mm) used in a fatigue test was available and was obtained from

[

3a.c.e. This material was in the aged condition, [

l la.c.e. A full size plan view (Xerox copy of the l

specimenplan)isshowninFigure2-12. The material was to oe an example of a low toughness material.per the techniques outlined in References 2.14 and 2.15 as part of a Westinghouse general research program. Three smaller bars of

(

1

'C were obtained at a later time from which tensile specimens were 8

made.

2-12 6

---,.-.n.

TABLE 2-1

~

MATERIALS SPEC'FICATIONS, CHEMISTRY AND MATERIAL PROPERTIES 0F [

]a,c.e a,c.e S

e W'

M

'M f

f 2-13 J

l i

XEYHOLE SPECIMEN (m)

~

1

r II 4 _

GERMAN DVM

?

8, W4 t

l L

ss I

isl

=.

l r

M SWISS VSM c'

m,' :%

i i

si i

is l Figure ~2-6a Dimensions on Swiss VSM and German DVM keyhole specimens

',o.

\\

l N

l l

P L /2 ---l

-2

= (c.079')

.2 s = =

g (0 01o") red.

L d "T")

A

~(f$[5 )

['3 7n) 45' L

TYPE A l--L4 ~

5== (0 197')

ag 7

l --l l-(o.394")T-to==

o

.hSAWCUT I

lo ""

.,65 )

@"~I 3 e==0/10

~

L TYPE 5 on Less l-- L A ---!

Sam p.1979 A

3_p,0.m n

.29 4 - l

~ (2. $~

[3,,) ~ ]2 =,=

9 TYPE C Figure 2-6b Charpy (Simple-Beam) Impact Test Specimens, Types A, B and C (ASTM E-23).

2-14

o a,c,e 9-Figure 2-7: CharpyU-NotchEnergyatRoomTemperaturefor[

Ja c.e 2-15 e

b

,7

, w ;-

. e,~.

.Q 4.' !

r,:;;r.

'f 4i n,

s

);

V

[

l l

,/

t i

r 1

{r.

I., i

/

i ey a,,c.e

.t j

i s

, s t,1

/.-

c p

't >

s 4

i

\\t i.

I i

1 l

\\'.

Y 9

i 4

P i

f l

9 l

4 P

l l

i l

t 1

i I

Figure 2-8: Charpy V-Notch Energy at Room Temperature and 500*F for [

3a.g,e 2-16

L

o a,c.e t

l

\\

l l

,a

~

t l

Figurc 2-9: J-integral Results at 600*F for [

3a,c.e, B = 0.34 in.

(Based on Defomation J Evaluation)

I 2-17

)

t

-- t t

'a b

w.

a,c.e

\\

s' 1

s i

Figure 2-10: J-integral Results at 200*F for [

3a.c.e B = 0.34 in. (Based on Deformation J Evaluation) 1 h

5

'~'

2-18 s

'=

1

a,c,e l.

l J-an Curves at Different Temperatures for Aged Material Figure 2-11:

[

]a,c.e 2-19 d

e t.

l 4 j:',- 9.E h R s * *

w' e -y.af. c.,* e V

~

(

'l

$$h$.

~

f Portion of Specimen er[

l

  • $j 4

l

-l lM[i.

] a.C.e.{

!ge..54p%,.

p ':%<J,a./. fg l

A.s.:::.? ;t: -:kr-7 2

..f.,ag

.l.

!. mAe :...

?Y

,.. WS 5??G.

crack orientation l

l i

l Figure 212: Full Size Plan View of Material Used in Investigation.

Thickness was 0.772 in. (20 m).

4 2-20 I

I

The specimen half of Figure 2-12 was first split to obtain two blanks, one e.4 in. (10 m) thick and the other #0.35 (9 m) thick. The test program reported here consisted of two parts. Initially, from the thicker sec-tion six standard compact specimens nominally 0.394 in. (10 mm) thick (2.12) and one standard Charpy V-notch specimen were obtained. The thinner section I

was saved for potential later investigations. The six 0.394 in thick compact specimens were numbered 78A9-1 through 6.

The Charpy specimen was numbered 78A.

The Charpy V-notch specimen was tested at 75'F and [

la.c.e of energy. The load-time curve is given in Figure 2-13. The compact speci-mens were tested at temperatures between -200*F (-129'C) and 550*F (288'C).

There was an instrumentation failure during one test and no data were obtained.

Essentially these five 0.394 in. (10 mm) thick compact specimens were tested per ASTM E 992-84.(2.16) Both load / displacement and load / time curves were obtained. If an instability was noted an unloading was attempted in an effort to determine the crack length as discussed in Reference 2.15.

The load displacement curves for the five compact specimens are shown in Figure 2-14.

Instability type behaviors past maximum load are noted for the specimens tested at -200*F (-129'C).150*F (66'C), and 200'F (93*C).

The results at 550*F (288'C) did not display instability indications and oddly enough neither did the room temperature result. For these specimens the maximum load fracture toughness, K-EE(2.16) and tearing modulus, Tmat.

as obtained by the procedures of Reference 2.14 were determined. These results are given in Table 2-2.

The best way to handle the tearing evaluation is not obvious. Tmat was calculated per Reference 2.1.4.

Generally Tmat is measured only for shelf (fully plastic) behavior with no. instability such as noted in the 75'F and 550*F test results. Tmat for the -200'F,150*F ard 200*F test results were calculated both by ignoring the instability and by taking it into account by limiting the final displacement to the displacement at which the instability occurred. Thusly, limiting the displacements produced the lower values for 2-21 b

a,,m

,i_,,g.4*-'s--

p 6

m44 L

4 i

4 b

g

?

f 1

O p.

i t

I STATICFRACTURETOUGilNESSPROPERTIESFOR{.c.e '

TABLE 2-2 J

n,Cet l

~

i I

i O

N e

i M

N t

of, t

' '.W * & n#

l e

}

' g

?

1 1

4 E

o I

8 1

-J A

i e

i s

v-

a,c.e t

4 4

m.us.

i Figure 2-13:

Load Time T, rag *e, for Charpy V-Notch Impact Specimen 78A of [

]*

Material Tested at Room Temperature w'

2-23 '

e

~ a,c.e j

i i

Figure 2-14: Load-Displacement Curves for the Five 0.394 in. Thick Compact Specimens Tested at Temperatures Between -200'F and 550*F (Note differences in scales and crack ratios) 2-24

e

-Tmat in Table 2-2 at the test temperatures of -200*F,150*F and 200*F.

Although, in the absence of full thickness specimen testing this is the conservative approach..it is anticipated that this approach may be very conservative for full thickness specimen results.

As seen in Table 2-2 the values of Tmat in the temperature range of interest, 200*F through 600'F, for the purposes of high en'ergy line breaks range from

[

3a c.e at 200*F to [ 3a,c.e at 600'F. Although one of the Tmat values [(

)]ac.e at 200*F is much lower than the values [(

)]a,c.e at 600'F, it is not significant because the piping loads associated with the 200'F temperature are a small fraction of the loads at operating temperature.

Therefore for cast stainless steel primary loop piping the Tmat at temperatures significantly below the 550*F operating temperature need not be considered for the evaluation procedure discussed later in this report.

As interest in and concern for thermal aging of cast stainless steel increased l

in the early 1980's, it was realized that the results obtained above were more l

than just another set of fracture toughness results for a low upper Charpy l

V-notch shelf material. Attempts to obtain additional [

3a,c.e material f

yielded only three small bars from which tensile specimens could be machined as previously noted. These tests were performed at room temperature and 600*F (316*C). The remaining #0.35 in. thick blank mentioned above was then machined to obtain 6 compact specimens nominally 0.34 in. thick and four subsize (reduced cross section) Charpy V-notch specimens. The compact speci-mens were numbered CT1 through 6.

Four of the specimens were tested pe. ASTM r

E-813(2.17) for determining J c using unloading compliance. Estimates for I

Jc and Tmat were obtained. Tests were performed at -320*F (-196*C),

I room temperature, 200'F (93*C) and 600'F (316*C). J-R curves for the 200*F (93'C) and 600'F (316'C) have been previously given in Figures 2-9 and

~

l 2-10,respectively, and were used as part of the data base in setting the

[

la c.e criteria discussed in the previous section. Two compact f

specimens were tested dynamically to resolve speculation about strain-rate I

sensitivity (2*I). The subsize Charpy specimens were tested at room temper-l ature 200'F (93*C) and 550*F (288'C).

2-25 l

t N

O

The true stress-true strain curves obtained at room temperature and 600*F(316'C) are given in Figure 2-15. Tabular data are also given in the figure and supplement the results given in Table 2-1.

Load displacement curves for the four statically tested.0.34 in. thick compact specimens are given in Figure 2-16. The room temperature and 600'F result exhibited no instability. Again the 200*F result would appear to give some indication of tearing instability although somewhat masked by the unloading and reloading. At -320*F (-193*C) an instability actually

-occurred right after an unloading compliances was performed; that is, the specimen just continued to tear as the load dropped. The J-Aa data for the specimens tested at -320*F and room temperature are given in Fisure 2-17 r.nd 2-18, respectively. The results from this second set of static tests are given in Table 2-2 also. Tmat was determined from the J-Aa data for these speci-mens. The J-R curve of the 600*F (316*C) static test was previously plotted in Figure 2-11 for comparison with the results of Reference 2.2.

The comparison is very complimentary. The maximum value of J (Jmax) obtained from i

the test at -320*F (-196*C) is (

3a c.e while for I

the 600*F (316*C) test Jmax is [-

la.c.e, Two compact specimens were tested dynamically at 600*F. Comparisons of the load-displacement curves with the static test curve are given in Figure

~

2-19.

For the dynamic tests only the maximum load toughness values were calculated. These values are also given in Table 2-2.

The four subsize Charpy V-notch specimens had the standard length of 2.165 in.

(55 an). The cross section was square and the V-notch was 20% of the total depth (i.e., except for length the subsize specimens were geometrically I

similartothestandardspecimen). Three specimens had a width equal to one-half of the standard Charpy specimen. The remaining one had a width equal j

to 87% of the standard Charpy specimen. The smaller specimens were tested at room temperature and 200*F (93*C). An a'dequate energy measurement was

~

l not obtained from one test. The larger specimen was tested at 550*F l

(288'C). Results from these tests and the prior full size specimen test j

are given in Table 2-3.

2-26'~

L

TABLE 2-3: CHARPY IMPACT ENERGIES FROM STANDARD AND NON-STANDARD SPECIMENS AT DIFFERENT i

IEMPERATURES FOR [

]a.c.e a,c.e mb-aWestinghouse Data bDimension of square cross section. Notch was 1/5 of B.

The length was as for a Standard Charpy Test (2.165 in., 55 mm)

CEstimated assuming specimens C3 and C4 were tested at same temperature l

l l

l l

~

4 e

w,

~

e.

[

e k..

I e

4,C,e s

I e

(

1 I

~

Figure 2-15:

rue-Stress True-Strain Curves at Room T ggtureand600'Ffor 2-28 l

l

'~

~

0,a,o I

E,c.e Load Displacement Curves for[

3ThickSpecimensof[

3a,c.e Figure 2-16:

Material Tested Statically Between -320*F and 600*F Using Unloading Compliance

?

2-29 i

s

0

.J

~

a,c.e i

i l

Figure 2-17: J-Integral Results at -320'F for [

3a,c.e(Based on Deformation J Evaluation) 2-30 1

,,,...,,,--.,--n--

,v-+r

--*----ma,- - ++- ---~ - - - -

- a c.e I

i 1

Figure 2-18: J-IntegralRegu{tgatRoomTemperature(75'F)for[

)

(Based on Defonnation J Evaluation) s 2-31 d

o i

a,c.e '

t J

i i

i Figure 2-19: Comparison of Static Load-Displacement Curve with Dynamic Load-Displacement Curves 'at 600*F ([

]a,c.e) i 4

2-32 n

1 r

\\-

It has been demonstrated that additional aging of (

Ja.c.e could result in further embrittlement of the ferrite as depicted by the lower temperature 4

fracture toughness tests. The behavior of the Jge estimates are plotted in Figure 2-20.. The most significant observation is that at -320*F

(-196*C) where the ferrite is surely completely embrittled, the J cI estimate is still around (

la.c.e jhis value then is the toughness of the austenitic matrix for [

la.c.e in the duplex geometry which exists. Since thermally aged cast stainless steel nuclear grade pipes of Type CF8M are expected to have quite similar micro-structure and chemistry,

]a,c.e for J c it a reasonable lower bound for a value of (

I suca CF8M pipes, even when the ferrite is completely embrittled if, as seen later, the ferrite content is that of (

la.c.e l

The load displacement curves given in Figures 2-14 and 2-16 show that plastic instability type behavior can occur up to 200*F (93*C). Such behaviors suggest that the tearing resistance is de, grading with decreasing temperature. Supplementing this, the tearing moduli of Table 2-2 also do not appear to present as an-optimistic view as J c.

The tearing moduli are I

plotted in Figure 2-21 as a function of temperature. [

i L

3a.c.e l

The dynamic results given in Table 2-2 suggest that the material is not

[

la.c.e at operating temperatures.

In this sense, I

Charpy impact results are judged to be indicative of (

ja.c.e In Reference 2.2 the room temperature Charpy U-notch results for

[

la.c.e are (

Ja.c.e On a per area basis the

(

la.c.e obtained from Charpy V-notch specimen 78A of Table 2-3 is

[

la.c.e. being in very good agreement with the U-notch results.

s 2-33 1'

d t

_s a,c.

5 i

l Figure 2-20: J as a function of Test Tgerature for[

3,c.e a

gg

/

2-34

- 9;_

e h

a,C,e e.

b e

P t

v e

M ib Figure 2-21: Variation df T with Temperature for[

[*

  • mat 2-35

-w-

i In Table 2-3, the subsize and full size Charpy results are consistent.

In the lower transition region one would expect the energy to vary somewhat as the cross sectional area just as in brittle fracture testing for K c.

For the I

room temperature results, the areas vary by a factor of ( 3a.c.e which is also the ratio of the energies [

la.c.e, For very high upper shelf Charpy behavior, the energies for subsize and full size Charpy specimens would vary somewhat as the cube of the scale factor.

For lower upper shelf values, variation with the cube of the scale factor is not expected to be realized. Thus the energy [

3a.c.e for the subsize Charpy specimen tested at 550*F should be scaled by some factor between [

la.c.e to obtain the full size Charpy energy. This gives between (

]a.c.e If the result at 200'F (93*C) and 550'F (288'C) were assumed to have been performed at the same temperature, a direct scaling can be performed. Such a scaling is reasonable since the 200*F (93'C) result does exhibit a slight increase in toughness over the corresponding room temperature test. The scaling produced an energy estimate for the full size Charpy specimen at 550'F (288'C) of (

Ja.c.e and this is the value plotted in Figure 2-8.

At 200*F (93*C) the increasing toughness of the subsize specimen suggests the full size Charpy specimen would exhibit increased toughness over the room temperature results. The near shelf result at 200'F (93*C) is based on experience and judgment.and is somewhat speculative.

I l

2.7 THE KCU FOR (

Ja.c.e In the prior section a Jrc of (

Ja.c.e in-1b/in2 was demonstrated for

[

3a c.e with fully embrittled ferrite. However, no impact tests were performed to obtain a corresponding KCU energy for the fully embrittled ferrite.

In this section such a KCU is set forth.

In Figure 2-16, the test at -320*F produced the J c of I 3"'*'*-

I The energy for the J e obtained from the R-curve is very close to the energy at I

maximum load of the load displacement curve.

2-36 L

A maximum load correlation of K with Charpy impact energy (KCV) is given in Reference 2.18. Although not verified for materials with low Charpy shelf behaving in a ductile manner such as the unembrittled austenite, a Charpy impact energy may be calculated from J c using K = (EJ c)l/. The I

I Charpy impact energy so obtained was [

3a.c.e Application of the Barson-Rolfe correlation (2.19) for K e using the,K obtained from J c was I

I

[

3a,c.e l

From the J e results plotted in Figure 2-20, it is obvious that Charpy I

energies at temperatures below the rocm temperature result of Figure 2-8 will be less than the (

la.c.e obtained at room temperature. While there are no definitive instabilities noted in Figure 2-13, pop-in type behaviors i

(blips) are noted up to point A.

It would be frivolous to say instabilities L

are occurring since machine instrumentation could be responsible for such blips. However, if one assumes the ferrite is breaking in cleavage up to point A, an estimate of the energy to fracture the austenite is approximately

[

Ja.c.e It is seen that each of the three above independent estimates of the fully aged Charpy'V-notch impact energy yields approximately [

la.c.e.

It is thus concluded that the fully aged Charpy V-notch energy for (

Ja.c.e is indeed around (

la,c.e and that value 4

will be used in the remainder of this report as the fully aged Charpy V-notch energy of (-

Ja.c.e, 1

I 2.8 FRACTURE TOUGHNESS FOR FULLY AGED CAST STAINLESS STEEL i

In this section a procedure is set forth for determining the fracture toughnesses for fully aged cast stainless steel. Such toughnesses form part of the basis for estimating toughnesses for materials which by a correlation procedure reviewed later, are less tough than (

la.c.e. The correlation is based on room temperature Charpy U-notch energies. Thus to establish the fully aged Charpy U-notch energy for [

la.c.e. the fully I

aged Charpy V-notch energy as discussed in Section 2.7 must be converted to Charpy U-notch energy.

i 2-3'7 J

o N

As reported in Reference 2-21, room temperature tests using both Charpy U-notch and Charpy V-notch specimens were made on the same stainless steel materials. A plot of the data with a parabolic curve fit is given in Figure 2-22. For a Charpy V-notch energy of [

la.c.e the corresponding Charpy U-notch energy (KCU) is [

]a.c.e. Thus the fully aged properties of (

la.c.e as discussed previously are summiar12cd as follows:

o,c.i 3a.c.e Tmat " I '3#

J,,x = [

Ja.c.e KCU = [

3a,c.e Here, for consistency with (

ja.c.e, Having thus determined the fully aged toughnesses for (.

]a.c.e. the remainder of this section is devoted to establishing a procedure for i

determining the fully aged toughnesses for any heat of cast stainless steel.

To do this [

.]a.c.e is used as a reference heat and its toughnesses are used as reference toughnesses.

For the embrittling situation considered, the ferrite content in relation to that of (

la c.e must also be addressed. The calculated ferrite l

content for [

la.c.e varies between [

la.c.e percent I

volume, having an average value of (

Ja.c.e percent. The ferrite in i

i percent volume may be determined from Reference 2.22.

l l

For the fully aged case as discussed for (

3 'C in the previous 8

l section, the ferrite is assumed to make no contribution to the fracture resistance. Referring to the discussion in Section 2.4, the amount of ferrite for the fully aged case is seen to have the potential for being a significant contributor to the fully embrittled fracture resistance. This is discussed below.

I 2-38 l

g a,c.e I.

i t

i

-i i

Figure 2-22 Correspondence Between the KCV Energy and KCU Energy of Austenitic Stainless Steels tested at 20'C O

I 2-39 J

The ferrite islands in austenitic stainless steel remain essentially the same size as seen in Figure 2-23(2.23); thus the austenitic matrix becomes finer and finer as the ferrite content increases. Assuming the random dispersion of the ferrite in the austenite is unchanged, the tortuous beam model discussed in Section 2.4 is utilized to determine the effect of changes in the amount of ferrite on the fracture toughness properties of cast stainless steel.

First the summation term of Equation (2-3), i.e.,

a k

2 I

I B

W (2-4) id 13 31 11 is considered. For this purpose the notation used is: F is the percent ferrite, A is the remaining part percent austenite (i.e., A = 100-F) and subscripts [ la.c.e and X refer to (

Ja.c.e and a heat of interest, Heat X, respectively.

(

i ja.c.e j

2-4d s.

... _, - ~ -. _ _ _........... _. _. _. _ -. - _. _ _. _. _. _. _ _ _.. _ __

w h:1.04 0.81 0.63 Thickness ;:...

(mm)..:.,., ' # ' '.J 5.

. ;.. :,,...: d

..: :.i. 9

4.2 4.4 s.1 dr% 1D 13.6 19.5 de: e.3 7.4 s.3

$% 3.1 14.8 234

.N dr:

7.7 to.e e.o

$*4 2.9 17.2 26A

'im O

b C

Figure 2-23: Micrographic features of two-phase specimens as a function of chemical composition Ni'eq/Cr'eq and thickness. The ferrite is colored by electrolytic etching in a 10-N sodium average segment intercepted by l

hydroxide solution, dp =ite content measured by micrography ferrite (um);6%=ferr t

2-41 g

(..

(

ja.c.e The question remains as to how the (

la.c.e affects J c, Tmat and Jmax. Fii'st if a Charpy impact specimen is tested I

in a slow' bend mode in the fully ductile region, the impact energy and energy from the slow bend mode are about the same. The model of Equation (2-3) was validated by dynamic tear (sharp crack) tests. Again in the ductile region, the impact and slow bend test energies are about the same. A slow bend test of a specimen having a sharp crack is a fracture toughness test from which J c, Tmat and Jmax could be determined. Thus the total energy from a I

fracture toughness test would vary with ( Ja.c.e just as for impact tests.

Since Jeax could be obtained for the full energy to instability, Jmax would vary as [ la.c.e Observing the -320*F result (Spec. CT4) of Figure 2-16, the energy to Jrc as seen in Table 2-7 (to be discussed later) is about [

la.c.e of that of Jmax." A (.

.]a.c.e of only (

Ja.c.e for Jmax yields the Jge value. It is censervative then to assume J c varies with (

la.c.e aNoting that J is proportional to the energy expended to the point where J is measured.

2-42 L

Thus, for a generalized fully aged heat of material (call it Heat X) with a variable [

.]a c.e J e (Heat X) = {

3a.c.e (2-9)

I Tmat (Heat X) = ( )

(2-10)

Jeax (Heat X) = (

Ja.c.e (2-11)

XCU(HeatX)=(

3a,c.e (2-12)

That is, J e (Heat X) = (

Ja.c.e (2-13)'

I Tmat (Heat X) = [ la.c.e (2-14)

Jmax (Heat X) = [

3a c.e (2-15)

KCU(HeatX)=(

.]a.c.e (2-16)

Thus, the fully aged toughness for any heat of cast stainless steel may be estimated.

It should be noted that (

ja.c.e, 2.9 EXPERIMENTAL VERIFICATION FOR FULLY AGED TOUGHNESS DETERMINATION Research is continuing on the long term effects of thermal aging on cast stainless steels at several facilities. The work of Trautwein and Gysel (Reference 2.1) continues to be extended at George Fischer, Ltd.,

Schaffhausen, Switzerland. The U.S. Nuclear Regulatory Comission is sponsoring aging investigations at Argonne National Laboratory (2.24, 2.25),

Unfortunately very little data are available which reasonably approach the fully aged state. The extensive program at Argonne National Laboratory anticipates some test results but no applicable data are currently available.

2-43 J

p.

1 3

The work at George Fischer, Ltd. apparently is not oriented towa~d frecture toughness (i.e., J c, Teat) testing but general trends and additional I

correlative type results are expected.

Some preliminary results, however, are available fron a (

lC which are judged to be fully aged or almost so. These are i -

discussed below.

3 A static heat of cast stainless steel was specis11y. made to obtiin a high aging sensitivity. The check analysis chemistry of the heat is as follom

~~

(weight %):

(

(

)e.c.e i

Aging was at 750*F (400*C) for 1000 hours0.0116 days <br />0.278 hours <br />0.00165 weeks <br />3.805e-4 months <br /> and 5000 hours0.0579 days <br />1.389 hours <br />0.00827 weeks <br />0.0019 months <br />. The ferrity i

is quoted as being between (

la.c.e. Specifically the ASTM ee'. nod based on the check analysis gave (

3a.c.e. the magnetic methcd gave

(

la.c.e and the' ASTM micrographic method gave (

la.c.e,. It -

s should be noted that the chromium content exceeds that of tha specification for CF8M (18 to 21%). Also the ferrite is well above the maximum anticipated ferrite content (

la.c.e for cast stainless steel pipe anj fittiris ur.ed in the Westinghouse type piping systems. However, metallurgical examir.ations confirmed that the microstructure of the test heat was typical of CF6M aM that the same mechanism of aging existed for this material aseixists for CF8M. The available results are gisen in Table 2-4 and are judged *to represent near fully aged conditions.

Using the above chemistry, the ASTM procedure as applied ly Westinghouse (2'22) gives a ferrite of (

3a.c.e. The discrepancy with the(

}C quoted is not yet resolved. Using the ferrite parcentage of

(

la.c.e the (

J'. C d. The predicted fully aged toughnesses may be found by.tquations 2-13 through 2-16 and are compared with the appropriate experimental asta in Table 2-6.

The 1r-prediction is seen to conservatively estimate th,e,tnerimental results.,

fact as discussed in the next section, the prediated Jge at the lower 95%

2-44

4 6

e t

e e

e s

5 ob E

b Eo YW W

K M

bad er e

N WN

>=

O e.

2-45 J

( '

4 e

s O

g J

a

<5 A

t.

Wr 2

D 3

m m

Cw J

o w

~m W 4 g >-

E 8a R$r

-EE 5 =E m

l m

a N

LaJ a

t e

i l

s 2-46 l

t 1

confidence leve) is [

la.c.e. less than the minimum J c I

determined experimentally. It is thus concluded that the available experimental data adequately confirms the viability of the (

Ja c.e of the predictive model.

2.10 UNCERTAINTY EVALUATIONS IN THE FRACTURE TOUGHNESS ESTIMATIONS A procedure is presented in the next section for estimating the service life toughness of highly thermally aged cast stainless steel. The procedure involves the fully aged toughness estimates discussed in Section 2.8 and the correlation equation developed by Slama(2.2). Both estimates involve uncertainties. These uncertainties are addressed in this section.

Essentially a procedure is derived for determining the 95% confidence level for the estimates.

For service life (32 full power years) thermal aging, an investigation of many heats of cast stainless steel of Westinghouse type nuclear steam supply systems have shown that degradation approaching or surpassing that of (

]C'E as discussed in Section 2.6 occurs only in the A351 Type CF8M cast stainless steel. Emphasis then is only on highly degraded cast stainless l

steel.

The equation derived by Slama(2.2) for service life of CF8M cast stainless steel is KCU = 52.5 - 2.19 (Si + Cr + Mo) + 46/F (2-17) where Si is silicon in percent weight, Cr is chromium in percent weight, Mo is molybdenum in percent weight and F is percent ferrite determined by the Schoeffermethod(2.22). Slama developed Equation (2-17) by fitting the data of fifteen heats of CF8 and CF8M therma 11y aged cast stainless steel aged for 10,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> at 752*F (400'C) t'aken from Reference 2.1.

As reported 2-47 J

s

,z F

in Reference 1.6 the standard error of estimate (actually referred to as the standard deviation in Reference 1.6) was [

]a.c.e(s),

Three data sources are currently available to compare with Equation (2-17) and such a comparison is shown in Figure 2-24. The CF8M data alone is plotted in Figure 2-25. One set of data plotted in that of Reference 2.1 which Slama(2.2) used to develop Equation (2-17). A second set of data is that obtained by Slama but not used in the multiple regression curve fit.

[

]a.c.e is one of these heats as noted in Figure 2-25. The third set of data is that developed at Argonne National Laboratory (2.24, 2.25). The l

comparisons of the calculated values with the experimental data is most often i

conservative in Figuras 2-24 and 2-25.

Using the data applied by Slama(2'2) in t'he regression fit, the 95% lower i

confidence levels for the calculated KCU values were determined by procedures given in Reference 2.26. The 95% lower confidence level is also plotted as a l

function of the calculated KCU values in Figures 2-24 and 2-25. With few exceptions the experimental data fall above this 95% lower confidence level.

Keeping in mind that [

3a.c.e with a calculated toughness of j

[

']a.c.e is the reference toughness, it is seen in Figures 2-24 and 2-25 that a calculated value of (

la.c.e is particularly significant in that for this calculated value er any greater calculated value, one is at least 95% confident that the calculated value equals to or exceeds that of the reference toughness [

]a.c.e.

Paraphrasing, if a value of at least [

la.c.e is calculated for a heat of cast stainless steel, then that heat is at least as good as [

]C 19 out of 20 times.

A second equation is given in Reference 1.6 which is applicable to CF8 and CF8A materials. The standard error of estimate for that regression equation is [

]a,c.e. Thus the uncertainty analysis pres:nted in this section envelopes that of the equation applicable to CF8 and CF8A cast stainless steel.

2-48

- - - -, ~ - - - - -,, - - < - -, _,, -

-e 8,C,8

~

+

+

E

'f l

l i

i i

I

.i i-FIGURE 2-24 Cooperison of Imperimental ECUS with Calculated KCUs for CF8M and CF8 Cast Stainless Steel 4

I 1

2-49 I

i~

J

e e

4 C,8 4

e FIGURE 2-25 Comparison of Experimental ECUS with calculated ECUS for C78M Cast stainless Steel only 2-50 L

"^

l In Figure 2-25, a vertical line is drawn for a calculated value of

(

la c.e.

All the data are seen to be above the lower 95%

confidence level for values less than [

la.c.e. Thus one concludes that if a calculated KCU value equals to or exceeds (

Ja,c.e. then the toughness values are at least those given by Equations (1-4), (1-5), and (1-6).

If a material fails to exhibit a calculated toughness of (

la.c.e, then one is not 95% confident it is as good as [

la.c.e. For this confidence level then, the material is not as good as (

Ja.c.e but on the other hand can be no worse than fully aged as discussed in Section 2.8.

However, Equations (2-13 through 2-16) do not account for the variability of the ferrite which goes into calculating the [

la.c.e. The 95%

lower confidence level for ( la,c.e is developed below.

It is first necessary to determine the variability in the ferrite calculation.

l Using the Schoeffer equation of ASTM A-800(2.22), the composition ratio used in l

determining the ferrite is a function of chromium, silicon, molybdemum, columbium, carbon, manganese, and nitrogen. The measurement of each of these elements is a random variable; thus the means and standard deviations of measurements of these elements are required.

The extensive chemical composition data of Reference 2.27 were used to determine the coefficient of variation (i.e., the standard deviation divided by the mean) l l

for the elements of interest. The results are given in Table 2-6.

The equation given in ASTM A-800(2.22) for calculating ferrite is:

F - 5.58175 x 10-4 2 + 4.22861 x 10-6 3 (2-18)

CR = 0.9 + 3.38883 x 10-2 F

F where CR is the composition ratio as given by:

CR=(Cr+1.5Si+1.4Mo+Cb-4.99)/(Ni+30C+0.5Mn+

26 (N-0.02) + 2.77)

(2-18a)

I where the elements are in percent weight and F is ferrite in percent volume.

l

~

2-51 l

l

_d

. ;k..

TABLE 2-6 COEFFICIENTS OF VARIATION FOR THE CHEMICAL ELEMENTS USED TO CALCULATE THE FERRITE CONTENT IN CAST STAINLESS STEEL i

)

ELEMENT COEFFIENT OF VARIATION l

(%)

l t

' Chromium 0.55 Nickel 0.80 Silicon 4.30 Holybdemun -

4.73 a

Columbium 93 E3 Carbon 21.2 Hanganese 7.27 Nitrogen 0.80 ihe columbian content is very small and is often not available. In calculating the ferrite a

it is taken as 0 (i.e., it doesn't enter into the calculation).

P 4

.e

k

[

Ja.c.e. The distribution of ferrite remains normal by the usual chi-square test (2.28),

a,c.e The coefficient of variation in calculating the [

3 given by Equation 2-8 was determined using an [

]"'C 5 coefficient of variation for the ferrite and the procedures of Refertnce 2.28.

For ferrite contents from 10 to 255, the coefficient of variation varied between [

Ja.c.e. The distribution remains normal using a chi-square test (2.28),

Thus to calculate the fully aged toughness of a heat from the reference toughness per Equations (2-13 through 2-16) at a 95% lower confidence level. [ la.c.e should be replaced by [

Ja,c.e. Hence to account for uncertainty in calculating the fully aged toughnes.s, Equations (2-13 through 2-16) become Jc=[

]8'Cd (2-19)

I Tmat " l 3a.c.e (2-20)

Jmax=1

]8'C'8 (2-21)

KCU = [

la.c.e (2-22)

Thus far uncertainty has been addressed for the calculated KCU value by showing that if the calculated value is at least [

3a c.e. then it is as good as [

la.c.e with a high degree of confidence.' The fully aged uncertainty is accounted for by Equations (2-19 through 2-22).

It remains then to address the uncertainty when the calculated KCU value is less than [

la.c.e but is not fully aged. This is done below.

2-53

_J

l The objective is to determine the KCU for purposes of application as discussed in '

the next section which accounts for uncertainty from a calculated KCU using l

Equation (2-17) falling between [

Ja,c.e and the fully aged

~

condition. Summarizing, the information in hand is as follows:

1.

For a calculated KCU of (

la.c.e, one is 95% confident it is at 2

least [

3a c.e daJ/cm,

2 la.c.e daJ/cm, one is 95% confident it is 2.

For a calculated KCU of (

2 at least [

la c.e daJ/cm,

It is to be noted that the coefficient of variation is approxim'ately [

la.c.e for Item 1 but only [

la.c.e for Item 2.

If one were to maintain the differencea[

ja,c.e for values less than [

la.c.e. then an anomaly would occur when the calculated value represents the fully aged condition. To wit, using (

3a.c.e as indication of the 95% confidence level, one would conclude that the fully aged condition exists when the calculated KCU value is equal to or less than (

Ja.c.e. On the other hand it has been shown that if the calculated KCU value is less than or equal to [

la.c.e. then a fully aged condition is assumed. These two values are in general not the same, the former usually being considerably less. This really comes about from applying the confidence level of a data fit to small values which cannot become zero or negative. Thus for small values the absolute data scatter must reduce.

l To resolve the above anomaly for a calculated KCU value falling between [

]a.c.e. the value for application (see next section) is to be obtained by interpolation to a value between (

3a.c.e. That is, for a calculated KCU value, call it KCU, the value for applications, call it KCUa, is found by

[

ja.c.e aihe difference changes very little from (

3a.c.e 2-54

o where interpolation is performed to determine the value for the question mark which is the desired KCUa-For later purposes, the interpolation formula is given in ratio form as follows:

(

la.c.e (2-23) 2.11 THE ALTERNATE TOUGHNESS CRITERIA In this section, alternate toughness criteria for cast stainless steel nuclear primary piping are set forth. The new criteria consists of two parts. First if the KCU correlation of Reference 2.2 for a piping component provides an end of life KCU greater than that for [

la.c.e at the 95% confidence level (i.e.,greaterthan(

la.c.e), then the [

la.c.e criteria reviewed in Section 1.0 are applicable. This could be a restrictive criteria for cast piping less prone to thermal aging embrittlement. However, for leak-before-break evaluations involving some twenty-five Westinghouse nuclear plants, the current [

la.c.e criteria have not proven restrictive. A less restrictive criteria than that based on [

la.c.e is not addressed in this report.

The second part of the alternate toughness criteria addresses the situation when the calculated KCU falls below that of (

3a,c.e with a 95%

confidence level (i.e., falls below [

la.c.e). One choice is of course to assume the material is fully aged if the calculated value is less i

than [

la c.e using Equations (2-19 through 2-22). However, this would be unduly restrictive since as has been demonstrated in the prior sections, the embrittling effect in terms of impact energy after long periods J c in turn reflects a gradual change with impact of time is very gradual.

I energy at low values as shown in Figure 2-26 (data sources are identified in thefigure). Thus an interpolation procedure is justified.

First the manner in which J c, Tmat and Jmax varies with calculated KCU I

values will be examined. There are [

la.c.e for thermally aged cast stainless steel available for which the operating 2-55 w

-r w,

r--

/

E, C,e Variation of J, with Charpy V. Notch Impact Energy Figure 2-26:

g

=

2-55

temperature J c and the room temperature impact energy are estimated I

including the set of. data presented in Section 2.9.

These are tabulated in Table 2-7.

These data are plotted.in Figure 2-27. Considering the data from Section 2.9 to be verification data illustrating the conservatism of the predictive model, the remaining data are seen to be reasonably linear. Thus interpolation is justified in determining the fracture toughnesses for a calculated KCU falling between [

-Ja.c.e, The procedure will first be outlined and then tabulated in summary fashion.

Having obtained the chemistry, hence the ferrite, for a heat, the calculated KCU may be found by Equation (2-17). As previously noted if the calculated KCU equals to or exceeds [

la.c.e the current criteria discussed in Section 1.0 applies.

If the calculated KCU is less than [

la.c.e then the [

),a.c.e is calculated by Equation (2-8).

If the calculated KCU is less than [

la,c.e. then the material is assumed to be fully aged and Equations (2-19 through 2-22) may l

be applied to determine the fracture toughness values.

If the calculated KCU is less than [

3a,c.e. then the KCU for application, KCUa, is obtained by Equation (2-23). KCu is to a

be used as a basis for interpolation the toughness values between a calculated KCU of [

la.c.e. The interpolation sets up as follows:

t.

For J c:

I i

l

[

ja,c.e where the question mark is the J e to be found by interpolation.

i i

l The interpolation ratio for J c is I

[

Ja.c.e (2-24) 2-57 j

r TABLE 2-7 JIc, Tmat max and J at Operating Temperatures for whch the [

3a.c.e is known 8,C,e i

e 8

\\

9 l

l O

_(

d

a,c.e t

l Plots of J c, Tmat and Jmax at Operating Temperature as Figure 2-27:

I a Function of [

.Ja,c.e 2-59

O O

g Noting that the left hand side of Equation (2-24) is the same as the left hand side of Equation (2-23), the interpolation set up for finding J c becomes I

(

3a.c.e which does not involve KCUa-In a similar manner, for Tmat

[

ja c.e where the question mark is the sought after Tmat-For Omax,

[

l l

Ja.c.e where the question mark is the Jmax to be found by interpolation.

Th'e interpolation schemes are outlined in Figure 2-28.

In practice, J c, I

Tsat and Jmax may be found by interpolating as indicated above or by using interpolation formulas.

f The procedures outlined in this section for using the alternate toughness criteria are summarized in Table 2-8.

Note that (

la.c.e l

are defined as follows:

2-60 l

Table 2-8 Outline of Procedure for Establishing Fracture Toughness 'of a Heat of Thennally Aged Cast Stainless Steel T

la.c, i

J 2-61

- - - - - - - - - - ~ ~ - ~ ~ ~ ~ - - - ~ ~

4.

. ~.

lN -.

1 i

I*

-- 4,C,e I

l 1-l ir i

il' i

e l

Figure 2-28 Sketch for Determining Fracture Toughnesses from Calculated KCU Values 2-62 t

t

7 a

[

ja.c.e, 2.12 SAMPLE APPLICATION OF THE ALTERNATIVE TOUGHNESS CRITERIA Table 2-8 explains how to apply the alternate toughness criteria. This section gives a direct application for a plant specific piping system. A two-loop plant is considered in this example; however, the procedure would be similar for three-loop and four-loop plants.

4 Chemistry and KCU Toughness

[

ja.c.e, For Heat X, the [

l I

I f

ja C,e 2-63 i

J

O O

TABLE 2-9 GEMISTRY AND CALCULATED [

]"'"'" VALLT.S FOR PIPE AND FITTINGS

_, a.Cse J

2-64 bu

[

ja.c.e For Heat Y, the [

Ja,c.e j

The As-built Loco Central File drawings are available for the as-built loops of each Westinghouse nuclear power plant. Thus, the location of each heat may be determined, A layout for a two-loop plant is given in Figure 2-29. The heats of Table 2-9 i

are identified with their locations in Figures 2-30, 2-31, and 2-32.

Toughness Criteria for the Example Application The alternate toughness criteria may now be applied following the steps outlined in Table 2-8. The toughness criteria so determined are given in Table l

2-10.

I 2-65

t 4

TABLE 2-10 Fracture Toughness Criteria for the Primary Piping Components of the Example Two-Loop Plant for End-of-Service Life

=

-' a,C,e i

4 8

4 9

l 7

I i

e 4

e W '

e

Steam Generator *

,,n, Crossover Leg Hot Leg 4,.

i,) Loop B Pump Reactor Vessel

,....., ~.

y

/

's Cold Leg

/

~.n.-

Loop A

,/ ~ '.

. '~..f

-N uf 1

  • g.

Figure 2-29 Typical Layout of the Primary Loops for a Westinghouse l

Two-Loop Plant 2-67 J

'0 a

Looo B i

Heat A

\\ REACTOR VESSEL

\\

\\

PUMP cn 1

1tb

/

Loop A Figure 2-30 Identification of Heats with Location for Cold Leg l

2-68 l

L

.)

Steam Loop B Generator (Reactor Heat X *

. essel "t

1 ia

,_/

l Loop A l

l l

  • The[

]a,c.e heat l

l Figure 2-31 Identification' of Heats with Location for Hot Leg l

2. _. _ _.

~. _ _

J

~

- ~

Steam Loop B Generator

'e s

HEAT Y* -

Pump

\\/

J Loop A i

  • The [

3a,c.e heat Figure 2-32 Identification of Heats with Location for Crossover Leg i

f l

2-70 L

o 3.0 DISCUSSION AND CONCLUSION The primary ebjective of this report is to develop a general methodology for estimating fracture toughness criteria applicable for leak-before-break evaluations of cast stainless steel piping which is quite sensitive to long term thermal aging. This has been accomplished in several steps. First, available information is reviewed and insight into the fracture behavior of steels is developed. Specifically, the energy disposition in fracturing specimens is demonstrated and applicability of an energy model developed for carbon steels is proposed for application to fully aged stainless steels.

Additional data are presented for the criterion material ([

la.c.e) and a generic toughness model keyed to [

la.c.e fracture toughness criteria 1s set forth. A comparison of model predictions and experimental results for l

a most extreme embrittlement demonstrates the model is adequate and conservative. Investigations in progress can be reasonably expected to further substantiate the model. Uncertainties in the data based parameters are addressed and are incorporated into the alternate toughness criteria at the 95% confidence level. Finally example applications of the alternate toughness criteria are set forth.

Based on the results presented, it is judged that a viable engineering methodology has been developed for establishing fracture criteria for thermally aged cast piping applicable for leak-before-break analyses.

3 9

d 3-1 a

i

+, -- _,. _.,. - -. _, - -,,, - - - _ _, _,

-w w-w

\\~

.. l a

4.0 REFERENCES

/'

i 1.1 S. S. Palusamy and A. J. Hartman, " Mechanistic Fracture Evaluatio'n i

of Reactor Coolant Pipe Containing a Postulated Through-Wall Crack",

Westinghouse Electric Corp. WCAP-9558 Rev. 2. May 1982 c,

(ProprietaryClass2).

1.2 E. I. Landerman and W. H. Bamford, Fracture Toughness and-Fatigue Characteristics of Centrifuga11y Cast Type 316 Stainless Steel After Simulated Thermal Service Conditions, presented at the Winter annual Meeting of the ASME, San Francisco, CA. December 10-15, 1978 (MPC-8, ASME).

1.3 W. H. Bamford, E. I. Landerman and E. Diaz, Thermal Aging of Cast Stainless Steel and Its Impact on Piping Integrity. ASME PVP-Vol.

95, Circumferential Cracks in Pressure Vessels and Pipina, Vol. II, pp137-172,(1984).

1.4 Nuclear Regulatory Commission 10 CFR Part 50, Modification of General

~

Design Criteria 4 Requirements for Protection Against Dynamic Effects of Postulated Pipe Rupture, Federal Register /Vol. 50, No. 126/ Monday, l

July 1, 1985/ Proposed Rules, pp. 27006-27009.

I e

l f,

1.5 Letter

B'. J. Youngblood, Chief Licensing Branch i 1. Division of licensing, USNRC, Washington, D. C. to R. J. Gary, Executive Vice President, Texas Utilities Generating Company. Dallas, Texas, dated March 2, 1984,

Subject:

Request For Additional Information Concerning Leak Before Break, Analysis For Comanche Peak Steam Electric Station (Units 1 and 2); Docket Nucbers 50-445/446.

s 1.6

'WCAP-10456, "The Effects of Thermal Aging on the Structural b

Integrity Cast Stainless Steel Piping For W NSSE," 3 'roprietary Class 2, November 1983.

4,

\\

I o

4-1

/

f N

ll x

o; o-1.7 Federal Register /Vol. 50, No. 203/ Monday, October 21,'1985/ Notices, Docket No. 50-412, Duquesne Light Company et al (Beaver Valley Power Station, Unit 2) Exemption,pp. 42624-42628.

1.8 Slama, G., Petrequin, P., Masson, S. H., and Mager, T. R., "Effect of Aging on Mechanical Properties of Austenitic Stainless Steel Casting Welds", presented at SMiRT 7 Post Conference Seminar 6 - Assuring Structural Integrity of Steel Reactor Pressure Boundary Components.

August 29/30, 1983, Monterey, CA.

2.1 A. Trautwein, and W. Gysel, " Influence of Long-time Aging of CF8 and CF8M Cast Steel at Temperatures Between 300 and 500 Degree C on the Impact Toughness and the Structural Properties". Stainless Steel Castings, ASTM STP 756, V. G. Behal and A. S. Melilli, Eds, American Society for Testing and Materials, 1981, pp 165-189.

2.2 Slama et al; same as Reference 1.8.

2.3 WCAP-10456'; same as Reference 1.6.

2.4 T. J. Nichol A. Datta, and G. Aggen, Transactions, American Institute of Mining, Metallurgical and Petroleum Engineers, Vol. II A, 1980, pp. 573.

2.5 R. O. Williams and H. W. Paxton, J. Iron Steel Inst., Vol. 185, 1957, pp. 358-374.

2.6 R. O. Williams, Trans. AIME, Vol. 212, 1958, pp. 497-502.

2.7 H. Hendry, Z. F. Mazur and K. H. Jack, Metal Science, August 1979, American Society for Testing and Materials, 1980, pp. 482-486.

i 2.8 R. R. Lula, Ed., Toughness of Ferritic Stainless Steels, ASTM STP 706 j

American Society For Testing and Materials, 1980.

l l

t l

l 4-2 t

2.8a N.*E.Devere11."ToughnessPropertiesofVacuumInductionMelted High-Chromium Ferritic Stainless Steels," Toughness of Ferritic Stainless Steels. ASTM STP 706.

R. A. Lula Ed., American Society for Testing and Materials,1980, pp.184-201. Also Letter from G.

~Aggen, Allegheny Ludium Steel Corporation Brackenridge, PA. to C. C.

Kim, Westinghouse Electric Corp., dated 2/26/85,

Subject:

Impact PropertiesofE-Brite(T.M.).

g 2.9 W. H. Bamford, et al. same as Reference 1.3.

2.10 F. J. Witt and R. G. Berggren, " Size Effects and Energy Disposition in Impact-specimen Testing of ASTM A 533 Grade B Steel"~ Experimental Mechanics, vol. 11 No. 5, pp. 193-201 (May 1971).

2.11 E 23 - Standard Methods for Notched Bar Impact Testing of Metallic Materials Annual Book of ASTM Sta$dards, Section 3 - Metals Test -

Methods and Analytical Procedures, Vol. 03.01, Metals - Mechanical Testing; Elevated and Low-Temperature' Tests.

2.12 E 399 - Stcndard Test Method for Plane-Stain Fracture Toughness of Metallic Materials, Annual ASTM Boox of Standards, Section.3 - Metals' Test Methods and Analytical Procedures, Vol. 03.01, Metals - Mechanic Testing, Elevated and Low-Temperature Tests.

2.13

[

3aA t:

2.14 F. J. Witt, Fracture Tougt % t 71 r eters obtained from Single Small l

Specimen Tests, WCAP-9397, Westinghcuse Electric Corp;, October 1978.

2.15 F. J. Witt, "An Engineering Interpretation of Pop-in Arrest and Tearing Arrest in Terms of Static Crack Arrest, Kla," Enginaering Fracture Mechanics, Vol. 18, Ho. 5, pp. 997-1010 (1983).

4-3

D 0

2.16 E 992 Standard Practice for Determination of a Fracture Toughness of Steels using Equivalent Energy Methodology, Annual ASTM Book of Standards, Section 3 - Metals Test Methods and Analytical Procedures, Vol. 03.01, Metals - Mechanic Testing, Elevated and Low-Temperature Tests.

2.17 E 813 - Standard Test Method for J c, A' Measure of Fracture I

Toughness, Annual Book of Standards, Section 3 - Metals Test Methods and Analytical Procedures, Vol. 03.01, Metals - Mechanical Testing; Elevated and Low-Temperature Tests.

2.18 F. J. Witt, " Relationships Between Charpy Impact Energies and Upper Shelf K e Values for Reactor Pressure Vessel Steels", Int. Journal I

of Pressure Vessels and Piping, Vol. 11, pp. 47-63 (1983).

2.19 S. T. Rolfe and J. M. Barsom, Fracture and Fatigue Control in Structures - Applications to Fracture Mechanics, Prentice-Hull, Chapter 6 (1977).

2.20 H. A. Ernst, " Material Response and Instability Beyond J Controlled Crack Growth", Elastic - Plastic Fracture: 2nd Sym. Vol. 1 In-elastic Crack Growth, ASTM STP 803, C. H. Shih and J. P. Gudas, i

Eds. American Society for Testing and Materials, 1983, pp. I-191 to I-213.

2.21

[

Ja.c.e 2.22 A800/A800M Standard Practice for Steel Casting, Austenitic Alloy, Estimating Ferrit'e Content Thereof, Section 1 - Iron and Steel Products, Vol. 01.02, Ferrous Castings; Ferroalloys; Shipbuilding.

4-4 i

2.23 M. T. Leger, " Predicting and Evaluating Ferrite Content in Austenitic l

Stainless Steel Casting," Stainless Steel Castings, ASTM STP 756, V.

G. Behal and A. S. Melilli, Eds., American Society for Testing and

' Materials, 1982, pp. 105-125.

2.24

0. K. Chopra and H. M. Chung, Long-Term Embrittlement of Cast Duplex Stainless Steels in LWR Systems: Annual Report, October 1984, f

September 1985, NUREG/CR-4503, Vol. 1. ANL-86-3 Argonne National Laboratory, January 1986.

l 2.25 Letter from W. J. Shack, Argonne National Laboratory to Dr. J.

Mascara, dated March 19, 1986, transmitting the December-January monthly report on the program "Long-Term Aging Embrittlement of Cast Duplex Stainless Steel in LWR Systems."

2.26 N.R. Draper and H. Smith, Applied Regression Analysis, John Wiley and Sons, Inc., New York, 1967, pp. 21-24.

i l

2.27 L. S. Aubrey, et. al.,." Ferrite Measurement and Control.in Cast Duplex Stainless Steel." Stainless Steel Castings, ASTM STP 756, American Society for Testing and Materials,1982, pp 126-164.

l 2.28 E. 8. Haugen,.Probabilistic Approaches to Design, John Wiley and l

Sons, New York, 1963, pp 105-128.

l I

4-5 l

_ _ _ _ _,