ML20214P532

From kanterella
Jump to navigation Jump to search
Addendum to 1986 Annual Rept,Consisting of Table 3, Radiological Analyses Results of Batch Water Released from Rwdf
ML20214P532
Person / Time
Site: Saxton File:GPU Nuclear icon.png
Issue date: 12/31/1986
From:
SAXTON NUCLEAR EXPERIMENTAL CORP.
To:
Shared Package
ML20214P322 List:
References
NUDOCS 8706030425
Download: ML20214P532 (1)


Text

..

TABLE 3 Radiological Analyses Results of Batch Water Released from the RWDF (uCi/ml)

Other Principal (a)

Fission / Activation Date Batch Cs-137 Eo-60 Products Cr Alpha Cr Bete H-3 12/08/86 120886A 1.4E-73 0E-8 < 4.0E-B LLD

< 3.0E-9 2.8E-7 5.6E-7 2.8E-7 1

.12/09/86 120986A 1.0E-7 3.0E-8

< 3.0E-8 LLD

< 2.0E-9 1.7E-7

< 3.0E-7 1

12/10/86 121086A 1.2E-7 4.0E-8

< 3.0E-8 LLD

< 3.0E-9 2.7E-7 5.0E-7 8.0E-8 3

1 12/11/86 121186A 1.6E-7 4.0E-8

< 4.0E-8 LLD

< 3.0E-9 2.7E-7 3.9E-7 8.0E-8 3

1 1.5E-7 3.0E-8

< 4.0E-8 LLD

< 3.0E-9 2.6E-7 12/11/86 1211868 3.0E-7 1.1E-7 1

1 1.4E-7 3.0E-8

< 2.0E-8 LLD

< 4.0E-9 3.8E-7 12/12/86 121286A 3.1E-7 1.0E-7 1

1 1.2E-7 3.0E-8

< 3.0E-8 LLD

< 3.0E-9 2.8E-7 12/15/86 121586A 3.2E-7 1.0E-7 1

1 1.2E-7 3.0E-8

< 3.0E-8 LLD

< 3.0E-9 2.8E-7 12/16/86 121686A 5.6E-7 8.0E-8 1

1 1.2E-7 3.0E-8

< 4.0E-8 LLD

< 3.0E-9 2.7E-7 2.1E-7+9.0E-8 12/16/86 1216868 1

1.4E-7 4.0E-8

<4.0E-8 LLD

<3.0E-9 2.7E-7 2.7E-7+1.5E-7 12/17/86-121786A 3

1.3C-7 3.0E 8 < 4.0E-8 LLD

< 3.0E-9 2.7E-7 12/17/86 1217868 3.7E-7 9.0E-8 1

3 1.4E-7 3.0E-8

< 2.0E-8 LLD

< 3.0E-9 2.6E-7 12/17/86 121786C 3.1E-7 7.0E-8 1

1 1.5E-7 3.0E-8

< 4.0E-8 LLD

< 3.0E-9 2.8E-7 12/18/86 121886A 2.7E-7 9.0E-8 1

1 1.6E-7 3.0E-8

< 2.0E-8 LLD

< 3.0E-9 2.8E-7 12/18/86 121886e 2.7E-7 7.0E-8 1

1 1.2E-7 3.0E-8

< 5.0E-8 LLD

< 3.0E-9 2.8E-7 12/18/86 121886C 2.9E-7 1.0E-7 1

1 1.3E-7 3.0E-8

< 3.0E-8 LLD

< 3.0E-9 2.8E-7 12/18/86 1218860 2.8E-7 1.0E-7 1

1 1.3E-7 3.0E-8

< 3.0E-8 LLD

< 3.0E-9 2.8E-7 12/19/86 121986A 3.0E-7 8.0E-8 1

1 1.4E-7 3.0E-8

<3.0E-8 LLD

< 3.0E-9 2.8E-7 12/19/86 121986H 5.0E 7 7.0E-8 2

1 1.6E-7 3.0E-8

<4.0E-8 LLD

< 3.0E-9 2.8E-7 12/22/86 122286A 1.9E-7 8.0E-8 1

1 12/22/06 1222868 1.3E-7+3.0E-8

< 4.0E-8 LLD

< 3.0E-9 2.6E-7 2.7E-7 1.3E-7 1

1.4E-7 3.0E.8

< 3.0E-8 LLD

< 3.0E-9 2.8E-7 2.6E-7 9.0E-8 12/23/86 122386A 1

1

'12/23/86 1223868 1.4E-7+3.0E-8

< 4.0E-8 LLD

< 3.0E-9 3.1E-7

3. 5E-7+1.0E-7 12/23/86 122386C(b)2.6E-7'4.0E-8 < 3.0E-8 LLD

< 3.0E-9 4.3E-7 2.9E-7[7.0E-8 2.0E-7 4.CE-8

< 4.0E-8 LLD 3.2E-9 3.0E-7

< 2.0E-7 _

12/29/86 122986A 1

2.0E-7 4.0E-8

< 4.0E-8 LLD 3.0E-9

3. 3E-7 2.8E-7 9.0E-8 12/29/86 1229868 1

3 2.1E-7 4.0E-8

< 4. 0E-8 LLD 5.3E-9 3.4E-7 1.9E 7 8.0E-8 12/30/86 123086A 1

3 1.9E-7 4.0E-8. < 4.0E-8 LLD

< 3.0E-9 3.0E-7 2.3E-7 9.0E-8 12/30/86 1230868 1

3 2.0E-7 4.0E-8

< 3.0E-8 LLD 4.7E-9 3.3E-7 3.5E-7 8.0E-8

.12/30/86 123086C 1

3 1.6E-7 3.0E-8

< 3.0E-8 LLD

< 2.0E-9 2.1E-7 2.8E-7 9.0E-8 12/31/86 123186A 1

1 1.8E-7 4.0E-3

< 3.0E-8 LLD

< 2.0E-9 1.6E-7 2.0E-7 8.0E-8 12/31/86 1231868 1

3 (a) Typical LLD's provided in Table 4 (b) Not discharged.

r a

0706030425 97 g 6 7

4o02 os g.

gg(

i

\\l

,