Text
e UNITED STATES t,
NUCLEAR REGULATORY COMMISSION
.j e
WASHINGTON, D. C. 20555
\\
/
9 9 SEF 1986 Docket Nos. STN 50-454, STN 50-455, STN 50-456, and STN 50-457 Mr. D. L. Farrar Director of Nuclear Licensing Comonwealth Edison Company P. O. Box 767 Chicago, Illinois 60690
Dear Mr. Farrar:
SUBJECT:
BYRON /BRAIDWOOD - R0D SWAP TECHNIQUE By letter dated October 24, 1983, Comonwealth Edison Company (CECO) submitted a request to use the rod swap technique and to use their CECO nuclear analysis methods in support of control rod worth measurements for Byron Units 1 and 2 and Braidwood Units 1 and 2.
We have reviewed this request and have concluded that the technique can be used and that Ceco can perform the nuclear analysis required for rod swap predictions.
It should be noted that use of rod swap is subject to the following conditions: (1) all banks (control and shutdown) will be measured,
(?) procedures as outlined in WCAP-9863-A will be followed, (3) design criteria, safety criteria and remedial actions will be as stated in References 1, 4 and 5 of the enclosed safety evaluation, and (4) a report comparing measured and predicted rod worths will be submitted to the NRC within 45 days of completion of the rod worth tests for the first use of rod swap on a reload at each unit.
./
/
or PWR Pro t Di ectorate #5 Divisio of PWR Licensing-A
Enclosure:
As stated CC:
See next page l
8609160439 860909 PDR ADOCK 05000454 P
ppg l
{
9 9 SEP 1986 M
Docket Nos. STN 50-454, STN 50-455, STN 50-456, and STN 50-457 Mr. D. L. Farrar Director of Nuclear Licensing Commonwealth Edison Company P. O. Box 767 Chicaco, Illinois 60690
Dear Mr. Farrar:
SUBJECT:
BYRON /BRAIDWOOD - ROD SWAP TECHNIQUE By letter dated October 24, 1983, Comonwealth Edison Company (CECO) submitted a request to use the rod swap technique and to use their CECO nuclear analysis methods in support of control rod worth measurements for Byron Units 1 and 2 and Braidwood Units 1 and 2.
We have reviewed this request and have concluded that the technique can be used and that CECO can perfonn the nuclear analysis required for rod swap predictions.
It should be noted that use of rod swap is subject to the following conditions: (1) all banks (control and shutdown) will be measured, (2) procedures as outlined in WCAP-9863-A will be followed, (3) design criteria, safety criteria and remedial actions will be as stated in References 1, 4 and 5 of the enclosed safety evaluation, and (4) a report comparing measured and predicted rod worths will be submitted to the NRC within 45 days of completion of the rod worth tests for the first use of rod swap on a reload at each unit.
Vincent S. Noonan, Director PWR Project Directorate #5 Division of PWR Licensing-A
Enclosure:
As stated cc:
See next page Distribution:
Docket FUes
~
NRC PDR Local PDR OGC-Bethesda T. Novak J. Partlow B. Grimes E. Jordan ACRS (10)
L. 01shan J. Stevens M. Rushbrook PD45 PD#5 DIR:PD#5
/
LOLshan JSte ns VNoonan j 9/$ /86 9/f/E 6 9/q/86
?
Mr. Dennis I.. Farrar Comonwealth Edison Company Byron /Braidwood cc:
Mr. William Kortier Dr. Bruce von Zellen l
Atomic Power Distribution Department of Biological Sciences Westinghouse Electric Corporation Northern Illirois University Post Office Box 355 DeKalb, Illinois 61107 Pittsburgh, Pennsylvania 15230 Joseph Gallo, Esq.
V. S. Nuclear Regulatory Comission Isham,l.incoln & Beale Byron / Resident Inspectors Office 1150 Connecticut Ave., N.W.
4448 German Church Road Suite 1100 Byron, Illinois 61010 Washington, D. C. 20036 Ms. Diane Chavez C. Allen Bock, Esquire 528 Gregory Street Post Office Box 342 Rockford, Illinois 61108 Urbana, Illinois 61801 Mrs. Phillip B. Johnson Thomas J. Gordon, Esquire 1907 Stratford I.ane Waaler, Evans & Gordon Rockford, Illinois 61107 2503 S. Neil Champaign, Illinois 61820 Douglass Cassel, Esq.
109 N. Dearborn Street Ms. Bridget I.ittle Rorem Suite 1300 Appleseed Coordinator Chicago, Illinois 60602 117 North Linden Street Essex, Illinois 60935 Ms. Pat Morrison 5568 Thunderidge Drive Mr. Edward R. Crass Rockford, Illinois 61107 Nuclear Safeguards and I.icensing Division David C. Thomas, Esq.
Sargent & l. undy Engineers 77 S. Wacker Drive 55 East Monroe Street Chicago, Illinois 60601 Chicago, Illinois 60603 Elena Z. Kezelis, Esq.
U. S. Nuclear Regulatory Commission Isham,l.incoln & Beale Resident Inspectors Office Three First National Plaza I
RR#1, Box 79 Suite 5200 Braceville, Illinois 60407 Chicago, Illinois 60602 l
i l
l