Text
.g, s
=
a m
a-
. ~
MAY 2 61987 J
Docket-No.50-029 Mr.- George Papanic, Jr.
Senior Project Engineer-Licensing
^
" Yankee Atomic Electric Company c
1671 Worcester Road Framingham, Massachusetts 01701
Dear Mr. Papanic:
SUBJECT:
EXEMPTION'FROM'THE REQUIREMENTS OF APPENDIX J TO 10'CFR PART 50, PARAGRAPH'III.A.3 The Commission has issued an exemption from certain requirements of Ap'pendix J to-10 CFR Part 50 in response to your letter dated April 17. 1987. The. exemption pertains to certain requirements of 10 CFR Part 50, Appendix J, " Primary Reactor Containment Leakage Testing for Water-Cooled Power Peactors," for all Type A.
(Containment Integrated Leakage Rate) tests to be' perfonned in accordance with the provisions of the American National Standard (ANSI) N45.4-1972, Leakage Rate Testing of Containment Structures.for Nuclear Reactors March 16, 1972.
This standard requires that containment. leakage rate calculations be performed using either the Point-to-Point method or the Total Time method.
In your letter dated April 17, 1987, you requested an exemption to allow use of the Mass Point method (as provided in ANSI /ANS 56.8-1981). The Consission
-l grants the exemption to use the Mass -Point method for calculating containment leakage, with the explicit condition that such tests be conducted with a minimum i
test duration of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. The exemption is granted until Section III.A.3 of Appendix J is modified.- The exemption applies only to the method of calculating leakage by use of the Mass Point method and not to any other aspects of the tests.
4 The bases for this action are included in the enclosed Exemption. Your letter has noted that you will propose an amendment to' the Technical Specifications (TSs) to maintain consistency _ between the TSs and the requested exemption. We will respond to the proposed amendment by separate correspondence.~
4 I,
1 1
4 I
~
8706010355 870526-PDR ADOCK 05000029 P
PDR 4
y-
,.-w
,r,y.
.r-
., p,, - - - -.
g-
_p
,c
-4 e--
.m, 7
y w
y
-f-w w
The Exemption is being forwarded to the Office of the Federal Register for publication.
Sincerdly, Eileen McKenna, Project Manager Project Directorate I-3 Division of~ Reactor Projects I/II
Enclosure:
Exemption cc w/ enclosure:
See next page
- SEE PREVIOUS CONCURRENCE i
0FC :PDI-3
- PDI-3
- PDI-3
- 0GC
- ADR1
- DRP NAME:*MRushbrook:*EMcKenna :*VNerses,
g
____:BBoher
. Ya DATE :0f/30/87 :09/;9/87 :05/36/87 :05/
87 :05/20/87 :05/tv/87._: Sgf/87 0FFICIAL RECORD COPY
AY 2 6 ggg7 Docket No.50-029 Mr. George Papanic, Jr.
. Senior Project Engineer-Licensing Yankee Atomic Electric-Company' 1671 Worcester Road J
Framingham, Massachusetts 01701
Dear Mr. Papanic:
SUBJECT:
- EXEMPTION FROM THE REQUIREMENTS.0F AP ENDIX J TO 10 CFR PART 50, PARAGRAPH III.A.3.'
The Commission has issued ~an exemption f certain requirements of Appendix J to 10 CFR:Part ~50 in~ response to your let,ter dated. April 17, 1987. The exemption pertains to certain requireme fs of 10 CFR Part 50, Appendix-J, i
" Primary Reactor Containment Leakage T ting fo'r Water-Cooled Power Reactors,"
for all Type A tests to be perfonned, n accordance with the provisions of the American National Standard (ANSI) N45.4-1972 Leakage Rate Testing'of Containment Structures for Nuclea lleactors, March 16, 1972. This standard
~
requires that containment leakag alculation be. performed using either the point-to-point method or the tot 1 time method.
In your letter dated April 1 1987, you requested an exemption to allow use of the mass-plot method (as provided in ANSI /ANS-56.8-1981). The Commission grants the exemption to us the mass-plot method for calculating containment leakage. The exemption }d granted until any final changes in rulemaking of Appendix J become effective. The exemption applies only to the method.of-calculating leakage by se of the mass-plot and not to any other aspects of
.the tests. The bases for this action are included in the enclosed Exemption.
Your letter has note that you will propose 'an amendment to the Technical Specifications (TSs) to maintain consistency between the-TSs and Appendix J.
We will respond to'the propo' sed amendment by separate correspondence..
The Exemption is/eing forwarded to the Office of the Federal Register for b
publication.
/
Sincerel,
Eileen McKenna, Project Manager-Project Directorate I-31 Enclosu/
Division of Reactor Projects I-II re:
Exemp 'fon cc w enclosure:
See next page OFC :PDI 3
- POI-3
- PDI-3
- 5PLB
- 0GC
- ADR1
- UMP
._f'
___._keh._______.____________.____________:___
NAME :
rook $EMc
- $jy
$JCraig-
- BBoger
$SVarga-n
__ _____ __ : _ ____ _______ : _f /3 0 /8 7
~
/ /87
/ /87-
- 1 J/ './87-DATE M /mo/87
- V/f//87
\\'
UttlGIAL MtLUMU LUVT
h...
, DISTRIBUTION
\\
+
Local PDR PDI-3 r/f-
~-
.BBoger-MRushbrook EMcKenna OGC-Beth-DHagan EJordan
- JPartlow TBarnhart (4)
WJon'es EButcher ACRS (10)
GPA/PA ARM /LFMB SVarga JPulsipher
- i ww
- +
w 7-
- +
,7- -,.
y v
p 4
r,.,
p-
Mr. George Papanic, Jr.
Yankee Atonic Electric Company Yankee Nuclear Power Station cc:
Mr. James E. Tribble, President Yankee Atomic Electric Company 1671 Worcester Road Framingham, Massachusetts 01701 Thomas Dignan, Esquire Ropes and Gray 225 Franklin Street Boston, Massachusetts 02110 Mr. N. N. St. Laurent Plant Superintendent Yankee Atomic Electric Company Star Route Rowe, Massachusetts 01367 Chairman Board of Selectmen Town of Rowe Rowe, Massachusetts 01367 Resident Inspector Yankee Nuclear Power Station c/o 11.S. NRC Post Office Box 28 Monroe Bridge, Massachusetts 01350 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 Robert M. Hallisey, Director Radiation Control Program Massachusetts Department of Public Health
- ~ ~
150 Tremont Street, 7th Floor Boston, Massachusetts 02111 l
i
'vW