ML20214K376
| ML20214K376 | |
| Person / Time | |
|---|---|
| Site: | Millstone |
| Issue date: | 08/14/1986 |
| From: | Martin T NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Opeka J NORTHEAST NUCLEAR ENERGY CO. |
| Shared Package | |
| ML20214K379 | List: |
| References | |
| NUDOCS 8608210060 | |
| Download: ML20214K376 (2) | |
See also: IR 05000245/1986014
Text
Ix
.
AUG 14 BB6
Docket Nos. 50-245
50-336
50-423
s
Northeast Nuclear Energy Company
ATTN: Mr. J. F. Opeka
Senior Vice President - Nuclear
Engineering and Operations Group
P. O. Box 270
Hartford, Connecticut 06141-0270
Gentlemen:
Subject: Combined Inspection Report Nos. 50-245/86-14; 50-336/86-15 and
50-423/86-22
.
.
An unannounced routine safety inspection of emergency preparedness activities
was conducted July 7-10, 1986, at Northeast Nuclear Energy Company's Millstone
Units 1, 2 and 3 Nuclear Power Station, Waterford, Connecticut, by Mr. J. Hawxhurst
and another staff member of this office. Discussions of our findings were held
by Mr. Hawxhurst with Mr. Romberg and other members of your staff at the con-
clusion of the inspection.
Areas examined during this. inspection are described in the NRC Region I
Inspection Report which is enclosed with this letter. Within these areas, the
inspection consisted of selective examinations of procedures and representative
records, interviews with personnel, and observations by the inspector.
Within the scope of this inspection, no violations were observed.
Your cooperation with us in this matter is appreciated.
Sincerely,
(h
wl:ul Sisued Br.:
(
Thomas T. Martin, Director
'
ivision of Radiation Safety
and Safeguards
Enclosure: NRC Region I Combined Inspection Report Nos. 50-245/86-14;
50-336/86-15 and 50-423/86-22
N[2gggy y
G
OFFICIAL RECORD COPY CIR MILL 86-14/15/22 - 0001.0.0
07/30/86
15
.f
I(
.,
-
-
i
. Northeast Nuclear Energy Company
.2
AUG l'41996
cc w/ enc 1:
E. J. Mroczka,- Vice President, Nuclear Operations
W. D. Romberg, Station Superintendent
D. O. Nordquist, Manager of Quality Assurance
R.' T. Laudenat, Manager, Generation Facilities Licensing
.
V. Papadopoli, Construction Quality Assurance Supervisor
E. R. Foster, Dir ntor of Generation Construction
Gerald Garfield, Csquire
Public Document Room (PDR)
Local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
NRC Resident Inspector
~ State of Connecticut
-bec w/ enc 1:
Region I Docket Room (with concurrences)
. Management Assistant, DRMA (w/o enc 1)
DRP Section Chief
M. McBride, RI, Pilgrim
P. Swetland, SRI, Haddam Neck
J. T. Shedlosky, SRI, Millstone 3
J. Shea,. LPM, NRR
Robert J. Bores, DRSS
L. Prividy, RI, BV-2
T. Rebelowski, SRI, Millstone 1&2
B. Doolittle, LPM, NRR
M
RI:DRSS
RI:DRS
RI:DRSS
R D SS
Hawxhu
Lazaru
Bellamy
Ma
in
7/9/86
f/jW86
f/l*/86
7
/6
,
0FFICIAL RECORD COPY CIR MILL 86-14/15/22 - 0002.0.0
07/30/86