ML20214J479

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-309/87-03 on 870317-0427.No Violations Noted.Two Errors Identified Re Inadvertent Initiation of Recirculation Actuation & Fuel Handling Machine Contact W/ Light Ring Indicate Need for Attention to Detail
ML20214J479
Person / Time
Site: Maine Yankee
Issue date: 05/19/1987
From: Wenzinger E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Randazza J
Maine Yankee
Shared Package
ML20214J482 List:
References
NUDOCS 8705280064
Download: ML20214J479 (2)


See also: IR 05000309/1987003

Text

.

...

.

.

.

-

-

. ___

_

- - . . .

ir

<e

,;

,.

1

9

e

MAY 19198T

,

Docket / License: 50-309/DPR-36

Maine Yankee Atomic Power Company

'

ATTN: Mr. J. B. Randazza

-Vice President

Nuclear Operations

i

83 Edison Drive

Augusta, Maine 04336

Gentlemen:

<

Subject:

Inspection Report No. 50-309/87-03

,

,

This transmits the March 17 to April 27, 1987, routine inspection findings of

Messrs. C. Holden and R. Freudenberger at the Maine Yankee Atomic Power Plant,

Wiscasset, Maine.

Those findings were based on observations of activities,. inter-

,

views, and document reviews, and have been discussed with Mr. Garrity of your staff.

Within the scope of this inspection, no violations were observed.

In general, the

refueling outage appears well run with good management overview of activities.

,

On the other hand, two errors which had the potential to adversely affect the out-

age (inadvertent initiation of recirculation actuation and the fuel handling ma-

chine contact with the light ring) indicate the continued need for attention to

'

i

detail at all levels.

No reply to this letter is required.

Your continued cooperation with us in this

matter is appreciated.

l

Sincerely,

1

Original Signed By8

,

Edward C. Wenzinger, Chief

s

d

Projects Branch No. 3

Division of Reactor Projects

Enclosure:

NRC Region I Inspection Report No. 50-309/87-03

cc w/ enc 1:

C.E. Monty, President

C.D. Frizzle, Assistant Vice President / Manager of Operations

J.H. Garrity, Plant Manager

i

P.L. Anderson, Project Manager

G.0, Whittier, Licensing Section Head

J.A. Ritsher, Attorney (Ropes and Gray)

i

Public Document Room (PDR)

Local Public Document Room (LPDR)

'l

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

State of Maine (2)

8705280064 G70519

f,

DR

ADOCK 0500

9

I\\

s

a

e

.

-,

.

Maine Yankee Atomic Power Company

2

n04Y 191987

.

bec w/ encl:

Region I Docket Room (with concurrences)

Management Assistant, DRMA (w/o encl.)

DRP Section Chief

M. McBride, RI, Pilgrim

H. Eichenholz, SRI, Yankee

P. Sears, LPM, NRR

DRP

I:DRP

DRP

eudenberger/meo

olden

T ipp

enzinger

5/13/87

f//9gf

0FFICIAL RECORD COPY