ML20214H349
ML20214H349 | |
Person / Time | |
---|---|
Issue date: | 11/21/1986 |
From: | Heishman R NRC OFFICE OF INSPECTION & ENFORCEMENT (IE) |
To: | Fisher A NEI PEEBLES-ELECTRIC PRODUCTS, INC. (FORMERLY PARSONS |
Shared Package | |
ML20214H353 | List: |
References | |
REF-QA-99901065 NUDOCS 8611260378 | |
Download: ML20214H349 (2) | |
Text
~*
s .
UNITED STATES
[
g g NUCLEAR REGULATORY COMMISSION
- j- W ASHINGTON, D. C. 2055%
k ,/
N vem er 21, 1986 Docket No. 99901065/86-01 Peebles Electrical Machines -
ATTN: Mr. A. S. Fisher General Manager East Pilton Edinburgh EH5 2XT Scotland Gentlemen:
This refers to the inspection conducted by K. R. Naidu of this office on October 6-8, 1986, of your facility Edinburgh, Scotland and to the discussions of our findings with you and members of your staff at the conclusion of the inspection.
The purpose of this inspection was to verify the implementation of your quality assurance program in areas relative to the manufacture of a spare electrical generator which was originally designed and manufactured by Electrical Products Incorporated located in Cleveland, Ohio, and supplied to the Diablo Canyon Nuclear Power Plant. Areas examined during the inspection and our findings are discussed
.in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.
The inspection identified a weakr.ess in the identification of materials supplied
'to you by your subsidiary in Cleveland, Ohio, which would have resulted in difficulties in providing traceability of the materials to their respective certification. We understand that you took immediate corrective action to resolve this matter.
In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.
Should you have r.ny questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely,
/
/ -
- N o ert F. Heishman, Chief 8611260378 861121 Vendor Program Branch Nolb99EN Division of Quality Assurance, Vendor and Technical Training Center Programs Office of Inspection and Enforcement 4
Enclosure:
4 Inspection Report 99901065/86-01 O,o f
? s\
l
. _ . . . . . __ . _ _ _ . . . _ . . _ . - . . . _ _ _ _ . _ _ ~ _ _ - - _ . . . _ _ _ . _ _ _ . - _. _ , . . _ _ _ ,_
Peebles Electrical Machines November 21, 1986 DISTRIBUTION: .
'QMdVPB Reading DQAVT Reading
-RStarostecki BGrimes HMiller RHeishman EMerschoff KNaidu JStone LParker E
i 4
1
/
B:DQAVT .DQAVT BC/VPB:DQAVT I
KNaidu:tt E schoff RHeishman
- 11/t1/86 1/iq/86 1 86
_. . - _ - - - _ ._