ML20213G784

From kanterella
Jump to navigation Jump to search
Forwards Application for Amend to License DPR-16,consisting of Tech Spec Change Request 155,incorporating Plant Mods,Per 10CFR50,App R & Updating Tech Specs to Add New Cable Spread Room.Fee Paid
ML20213G784
Person / Time
Site: Oyster Creek
Issue date: 11/07/1986
From: Fiedler P
GENERAL PUBLIC UTILITIES CORP.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20213G786 List:
References
NUDOCS 8611180331
Download: ML20213G784 (2)


Text

GPU Nuclear Corporation 9 Nuclear

= = = 388 Forked River. New Jersey 08731-0388 609 971-4000 Writers Direct Dial Number:

November 7, 1986 Director Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555

Dear Sir:

Subject:

Oyster Creek Nuclear Generating Station Docket No. 50-219 Technical Specification Change Request No.155 GPU Nuclear Corporation, operator of the Oyster Creek Nuclear Generating Station, Provisional Operating License No. DPR-16, requests changes to the Technical Specifications.

These changes are requested to incorporate plant modifications being accomplished to meet the requirements of 10CFR50, Appendix R and to update the Technical Specifications with regard to the addition of a new cable spread room. Administrative changes are requested to reflect the current revision of the Oyster Creek Fire Hazards Analysis.

By letter dated March 24, 1986, the NRC staff granted several exemptions requested by GPU Nuclear. This correspondence provided the staff's Safety Evaluation Report (SER) for the requested exemptions and the Alternate Shutdown Facility provided to meet 10CFR50, Appendix R.

In their SER the NRC staff requested GPU Nuclear to submit Technical Specifications for air accumulator tanks and spare air bottle to assure operability of the "B" Isolation Condenser.

GPU Nuclear has considered changes to the Technical Specifications to reflect air accumulators; however, it is felt that such changes are not necessary nor desirable. The air accumulators are passive components which are not subject to operational controls. The design of the accumulators provides a backup source of air to a control valve. The accumulator tank size is sufficient to provide a minimum of 10 valve cyclings even though analysis shows that only 6 cyclings are required.

Since the air accumulators are installed as an integral part of the system, the existing Technical Specifications f or the system provides sufficient operability constraints. The spare air bottle in the local area has been provided for convenience and to further assure pressurized air will be available in the long term. Availability of this air bottle is not required to assure timely action in a fire event; therefore, the addition of Technical Specifications is unwarranted.

(

8611180331 861107 DR ADOCK 05000219 p

PDR 3

GPU Nuclear Corporation is a suommm y of the General Pubhc Utihties Corporation i

ktC U lfC U e C k Y f S ' &

Nuclear R:act:r R:gulation Pag 2 2 This Technical Specification Change Request has been reviewed and approved by Responsible Technical and Independent Safety Reviewers in accordance with Technical Specifications section 6.5.

A check in the amount of $150.00 is enclosed pursuant to 10CFRi?0.21.

If you should have any questions regarding this matter please contact Mr.

George Busch at (609)971-4909.

Very truly yours,

_ adIdI,

Peter u. Fiedler Vice President and Director l

Oyster Creek PBF/GB/ dam (0240A)

Attachments cc:

Dr. Thomas E. Murley, Administrator 4

Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406 Mr. Jack N. Donohew, Jr.

U.S. Nuclear Regulatory Commission i

7920 Norfolk Avenue, Phillips Bldg.

Bethesda, MD 20014 Mail Stop No. 314 NRC Resident Inspector l

l Oyster Creek Nuclear Generating Station i

Forked River, NJ 08731 l

l l

l I

- - - -