ML20213D091

From kanterella
Jump to navigation Jump to search
Submits Info Re Steam Generator Plugging for Current Refueling Outage Completed on 860307.Once-Through Steam Generator a Had 4 Tubes Removed from Svc by Plugging & Once-Through Steam Generator B Had 47 Tubes Removed
ML20213D091
Person / Time
Site: Oconee 
Issue date: 07/22/1986
From: Tucker H
DUKE POWER CO.
To: Grace J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NUDOCS 8611100420
Download: ML20213D091 (1)


Text

.

[

DuxE POWER GOMPANY P.O. BOX 33189 CHARLOTTE, N.c. 98949 HAL B. TUCKER TELEPROltE (704) 373-48(M vuos ye we

-July 22,.1986

Dr. J.; Nelson Grace, Regional Administrator U.S. Nuclear Regulatory Commission - Region II c.,-

101 Marietta Street, NW, Suite 2900 c_.

. Atlanta, Ga.

30323 f5 S$

Subject:

. Oconee Nuclear Stat on, Unit 1 p

Docket Nos. 50-269 m

e.o

Dear Dr. Grace:

0::)

Pursuant to Oconee Nuclear Station Technical Specification 4.17.6(a), Duke Power Company (Duke) is providing the following'information concerning the Oconee Unit I steam generators. The steam generator plugging for the current Unit I refueling outage was completed on March 7, 1986. The "A" OTSG had a total of four (4) tubes removed from service by plugging. The "B" OTSG had a total of forty-seven (47) tubes removed-from service by plugging.

Very truly yours, Hal-B. Tucker PJN/49/jgm Attachments xc:

Mr. Harold R. Denton Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Ms. Helen Pastis Office of Nuclear Reactor Regulation

-U.S. Nucle.-c Regulatory Consission s

Washington, D.C.

20555 Mr. J.C. Bryant NRC Resident Inspector Oconee Nuclear Station

\\

8611100420 860722 y

i O PDR ADOCK 05000269 PDR P

.,,,