ML20212Q330
| ML20212Q330 | |
| Person / Time | |
|---|---|
| Site: | LaSalle |
| Issue date: | 08/19/1986 |
| From: | Allen C COMMONWEALTH EDISON CO. |
| To: | Harold Denton Office of Nuclear Reactor Regulation |
| References | |
| RTR-NUREG-0313, RTR-NUREG-313 1998K, GL-84-11, NUDOCS 8609040213 | |
| Download: ML20212Q330 (4) | |
Text
\\.
I A COHHBORW6alth Edlaen n
One First Nabonal Plaza. Chicago, IRinois Address Reply to: Post Offm Box 767 Chicago, IRinois 6069C 0767 August 19, 1986 Mr.' Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555
Subject:
LaSalle County Station Unit 2 Stainless Steel Piping Inspection Plan, Fall 1986 Refueling Outage NRC Docket No. 50-374 Reference (a): Letter from J..A.
Zwolinski to D. L.
Farrar dated January 7, 1986.
Dear Mr. Denton:
In accordance with the referenced letter, this transmittal provides our piping inspection plan for the LaSalle County Station Unit 2 Refueling 3
Outage. The inspection plan was prepared consistent with the guidance in Generic Letter 84-11.
Attachment A provides a general description of the inspection plan including inspector qualifications and provisions for crack evaluation and l
sample expansion. Also included is a table detailing the number of welds by system and pipe size to be examined.
Commonwealth Edison is aware that the NRC intends to issue NUREG-0313 Revision 2 for conunent at some point in the future. However, since these new requirements have not yet been issued, we have established our l
inspection plan in accordance with the ' existing regulatory require:nents and submitted it for your review on the schedule required in the referenced letter. To avoid any impact on our refueling outage schedule, we request yout: concurrence with the attached inspection' plan as soon as possible. The
~
Unit 2 outage is currently scheduled to begin in December 1986.
In accordance with the requirements of 10 CFR 170.12, a fee remittance in the amount of $150.00 is enclosed.
Il g
lg6 8609040213 060819 a
DR ADOCK 0500 4
4 l
- n \\
k
o Mr. H. R. Denton August 19, 1986 If you have any questions regarding this transmittal, please contact this office.
One signed original and forty (40) copiec of this letter and the attachment are provided for your use.
Very truly yours, C. M. Allen Nuclear Licensing Administrator 1m Attachment cc: Resident Inspector - LaSalle County Dr. A. Bournia - NRR 1998K
~ -. -
\\'
ATTACIWWNT A OUAD CITIES UNIT 2 FALL 1986 OUT7sGE PIPING INSPECTION PLAN 1.
During the Preservice Inspection, Induction Heat Stress Improvement (IHSI) was performed on approximately 80 welds. It is planned to perform Stress Improvement on approximately 40 additional welds.
2.
The accompanying tabic titled, "LaSalle County Station Unit 2, 84-11 Augmented Inspection Plan", provides the sampling plan for addressing the Intergranular Stress Corrosion Cracking (IGSCC) concerns during the LaSalle County Unit 2 Fall 1986 outage. The augmented inspection will consist of 31 weld examinations.
3.
All stainless steel weld examinations will be performed by special Level II inspectors, qualified by EPRI after September 1985. Examinations on
~
weld overlays will be performed by a special Level II inspector qualified by EPRI to inspect weld overlays.
4.
Each flaw indication will be evaluated in accordance with the guidance of NURBG-1061 Volume 1 and GL 84-11.
If repairs are required, weld overlays will be utilized which take into account flaw characterization, depth, length, and material toughness concerns for SMAW and SAW
[
deposited material. All welds with an axial crack will have an overlay i
repair applied.
If there is a flaw indication that is less than or equal to 10% of circumference and less than or equal to 30% in depth and stress improvement has been applied, the crack growth analysis will include the beneficial residual stress pattern from stress improvement.
5.
If cracks are found within the inspected sample of a specific piping category, another equivalent sample of the same number in that category will be inspected. Categories are defined by the horizontal lines on the accompanying table.
For example, the first category is Recircula-tion which would include risers, header.and outlets.
l 1998K l
ATTACHMENT 1 LASALLE COUNTY STATION UNIT 2 84-11 AUGMENTED INSPECTION PLAN To Be Solution Resistant Stress 84-11 ~
84-11 System Size Total Annealed Material Improved Total
'Sanele RECIRCULATION 24" 46 4
0 5
42 8
16" 16 8
0 0
8 4
12" 60 0
30 10 30 6
RESIDUAL HEAT 20" 11 0
0 9
11 4
REMOVAL 12" 15 2
0 8
13 4
RECIRCULATION 4"
31 6
0 14 25 5
RESIDUAL HEAT REMOVAL, JET PUMP INSTRUMENT 179 20 30 46 129 31 COLUMN 3 - Total welds on a particular system or size.
4 - Total welds that are solution annealed. These welds are resistant to ICSCC and will be inspected under Section XI requirements.
5 - These welds join 316K material. This material is equivalent to 316L and has a carbon content of.02% maximum.
These welds will be inspected under Section II requirements.
l 6 - Total welds that are scheduled to be stress improved this refuel outage. The nu.nber of welds could be reduced if stress improvement is not performed on all welds.
7 - Total welds that fall under the Generic Letter 84-11 requirements.
8 - Minimum 84-11 stanple.
1998K
. -