AUG 2 7 li$$
Docket No.50-029 Mr. George Papanic, Jr.
Senior Project Engineer-Licensing Yankee Atomic Electric Company 1671 Worcester Road Framingham, Massachusetts 01701
Dear Mr. Papanic:
Re: Yankee Nuclear Power Station
SUBJECT:
SECTIONS III.G.3 AND III.L OF APPENDIX R TO 10 CFR PART 50 (SAFE SHUTDOWN CAPABILITY IN THE EVENT OF A FIRE)
By letter dated April 12, 1983, Yankee Atomic Electric Company (YAEC) submitted a proposal to provide an integrated safe shutdown system which could be used for safe shutdown in the event of a fire at Yankee. Further information was provided by letters dated June 9, 1983, February 15 and December 28, 1984, April 30 and November 7, 1985 and March 5, 1986.
As discussed in the enclosed safety evaluation report, the staff concludes that with installation of the dedicated safe shutdown system and the other plant modifications, the requirements of Section: III.G.3 and III.L of Appendix R to 10 CFR Part 50, with respect to safe shutdown in the event of a fire are met. However, it should be noted that your request for exemptions from certain requirements of III.G.2 and III.G.3 for selected plant areas remains under staff review.
It is our understanding that the actions necessary to place the dedicated shutdown system into an operational status will be completed by the end of the Cycle 19 refueling outage. Please notify us in writing cf any significant changes in the estimated compleiion schedule and when the actions are actually completed.
S l
Eileen F. McKenna, Project Manager Project Directorate #1 Division of PWR Licensing-A
Enclosure:
As Stated cc's:
See Next Page Office:
LA/ PAD #1 PM/ PAD #1 PD/ PAD #1 Surname: *PShuttleworth
- EMcKenna/lp
- Glear Date:
08/22/86 08/25/86 08/27/86
- See previous concurrence.
8607030469 860027 PDR ADOCK 0S000029 F
Mr. George Papanic, Jr.
Yankee Atomic Electric Company Yankee Nuclear Power Station cc:
Mr. James E. Tribble, President Yankee Atomic Electric Company 1671 Worcester Road Framingham, Massachusetts 01701 Thomas Dignan, Esquire Ropes and Gray 225 Franklin Street Boston, Massachusetts 02110 Mr. N. N. St. Laurent Plant Superintendent Yankee Atomic Electric Company Star Route Rowe, Massachusetts 01367 Chairman Board of Selectmen Town of Rowe Rowe, Massachusetts 01367 Resident Inspector Yankee Nuclear Power Station c/o U.S. NRC Post Office Box 28 Monroe Bridge, Massachusetts 01350 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 Robert M. Hallisey, Director Radiation Control Program Massachusetts Department of Public Health 150 Tremont Street, 7th Floor Boston, Massachusetts 02111
't '
3 Distribution Copies:
pocket w :90&O29' NRC PDR Local PDR PAD #1 r/f PAD #1 p/f TNovak,'Actg. DD
.NThompson, DHFT OGC-Bethesda
~EJordan BGrimes JPartlow Glear PShuttleworth EMckenna LFMB(TACNos. 53626 & 51804)
ACRS(10)_
k t
+