ML20212N848

From kanterella
Jump to navigation Jump to search
Forwards Comments on Health Physics Monitoring Plan for Durango,Co Umtrap Site,Submitted on 860708.Proposed Surface & Groundwater Monitoring Programs Fail to Meet Requirements of 860328 Generic Health Physics Monitoring Plan
ML20212N848
Person / Time
Issue date: 08/18/1986
From: Pettengill H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Themelis J
ENERGY, DEPT. OF
References
REF-WM-48 TAC-50136, NUDOCS 8608290215
Download: ML20212N848 (2)


Text

DISTRIBUTION

^b~%

Docket File No. WM_48 NPDR/DCS DBangart, RIV RBrich WM-48/RFB/86/08/09/0 URF0/rf

~

~

LLW Branch, WMLU AUG 181986

~

l URF0:RFB Docket No. WM-48 TAC # 50136 John C. Themelis, Project Manager Uranium Mill Tailings Project Office U.S. Department of Energy Albuquarque Operations Office P.O. Box 5400 Albuquerque, New Mexico 87115

Dear Mr. Themelis:

We have completed our staff review of the Health Fhysics Monitoring Plan for the Durango, Colorado UMTRA site. You provided this plan to us by letter dated July 8,1986, for infonnational purposes as directed by the existing DOE /NRC Memorandum of Understanding.

As requested, our review

.connents are enclosed.

Our comments reflect the requirements of the generic " Health Physics Monitoring Plan" dated March 28, 1986.

In general, the proposed surface water and ground water monitoring programs fail to meet the requirements of this plan.

Thank you for the opportunity to comment on the Durango Health Physics Monitoring Plan.

Should you have ar.y questions regarding these connents, please contact Randy Brich on FTS 776-2819.

Sincerely, 8

Harry J.

ettengill, Chief Licensing Branch 2 Uranium Recovery Field Office l

Region IV

[

Enclosure:

As stated cc: Johno D' Antonio, DOE /AL l

@C :

l..__:URF0'..T. :.U.R.F.__

_ {R,,B,r,1,c,h,/,r,s,,,,H,P,e,t,te,n_g,1,1,1, {

,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,[,,,,,,,,,,,

% ATE:86/08/0 g

V608290215 86081E i

PDR WASTE

(

WM-48 PDR

Q e

NRC COMMENTS ON THE HEALTH PHYSICS MONITORING PLAN FOR THE DURANGO, COLORADO UMTRA SITE 1.

Page F-11, Section 8.3-As stated in Section 3.4.2.2 of the generic " Health Physics 1

Monitoring Plan" dated March 28, 1986, major surface water drainage systems will be sampled and analyzed quarterly the same as ground water. However,(as proposed in the Durango liealth PhysicsHPMP) surface wate Monitoring Plan i

be monitored and analyzed quarterly only for Ra-226 and Th-230.

Therefore, compatible analyses shou 1T5e performed for both the ground water and surface water.

2.

Page F-12, Sections 8.3.B and C -

Section 3.4.2.1 of the generic " Health Physics Monitoring Plan" dated March 28, 1986, states that quarterly monitoring of ground water shall be conducted and analysis performed for uranium-chain isotopes, specifically, U-238, Ra-226 and Th-230. However, Section 8.3.C of the Durango HPMP does not include monitoring for i

U-238, Ra-226 and Th-230.