__
=
1
.d6 AUG 211g i
Docket No: 50-354 i
Public Service Electric & Gas Company i
ATTN: Mr. C. A. McNeill, Jr 4
Vice President - Nuclear Post Office Box 236 Hancocks Bridge, New Jersey 08038 Gentlemen:
Whenever Region I participates as a player in a licensee exercise, _we request that representatives from the licensee's Emergency Preparedness' staff provide the Region I staff a training session on their emergency _ organization, facil-ities, and procedures.
The feedback from these sessions has been most en-l couraging.
Both the licensee and NRC staffs have found these sessions very 1
beneficial.
Since Region I is planning to participate in your November 13, 1986 Hope Creek exercise, I would like to request Dennis McClosky, and other appropriate members of your staff, to provide a briefing / training sassion on-the Hope Creek Nuclear Power Facility and Emergency Response Organization, at the Region I office on November 5,1986 at 9:00 a.m.
i The agenda is flexible.
Although I have attached an agenda from a previous training session, you should~ not feel constrained to follow it.
Your agenda should reflect those items of your Emergency Response Program your staff feels i
NRC personnel should be particularly knowledgeable in, to ensure a well coordinated NRC-Licensee response to the emergency.
Previous training sessions have varied from three to five hours, depending on the type of 1
training and issues of concern.
If there are any questions on this matter, please contact K.
Ferlic I
of my staff at (215) 337-5083.
SMa% gC=M2; 7_
i I
W
]
T
. Mart n, Director ivision of Radiation Safety and Safeguards i
Enclosure:
Sample Agenda 4
0FFICIAL RECORD COPY 860E280203 860821 PDR ADOCK 05000354-F PDR 4
i 1
Public Service Electric & Gas Company 2
i cc: w/ encl:
P. R. H. Landrieu, Vice President - Engineering (Newark)
R. S. Salvesen, General Manager, Hope Creek Operations A. E. Giardino, Manager, Station Quality Assurance W. H. Hirst, Manager, Joint Generation Projects Department, Atlantic Electric Company L. A. Reiter, General Manager - Licensing and Reliability Rebecca A. Green, Bureau of Radiation Protection Public Document Room (POR)
Local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
NRC Resident Inspector j
State of New Jersey bcc w/ encl:
Region I Docket Room (with concurrences)
Management Assistant, DRMA (w/o encl) j DRP Section Chief Robert J. Bores, DRSS t
4 i
\\
J i
l 4
i l
1 RI:DR RI:
RI:DRSS RI:DRSS'[
Ferli Lazarus Bellamy TMartin 86. 7, 8/
8/js/86 8/)4/86 84Ad/86 0FFICIAL RECORD COPY I
t
.,-m.
.,,m..
---..y
-,--r_..,.,
1 Sample Agenda I.
Introduction to Facility (10 Minutes)
A.
Site and Area Layout j
B.
10 Mile EPZ II.
Facility Emergency Response Organization (20 Minutes) l A.
Onshift B.
'D.
Media Operations Center III.
Emergency Response Comunication System (20 Minutes)
A.
Activation of the Emergency Organization i
B.
Telecomunications Network 1.
Internal Comunications 2.
Offsite Agency C'omunications C.
Radio Network D.
Data Comunications E.
Alert Notification Systems IV.
Emergency Response Facilities (25 Minutes)
A.
Control Room / Operations Support Center
'8.
Technical Support-Center 1 C.
Emergency Operations Facility / Backup D.
Media Operations Center / Backup i
E.
General Office Emergency Response Facilities V.
Conduct of Exercises (20 Minutes)
A.
Exercise Organization / Structure B.
Scenario Development 1.
Scope and Objectives C.
Precautions and Limitations 1.
Etiquette l
D.
Participation Organizations for Exercise 0FFICIAL RECORD COPY 1
}
l
VI.
State, County, Local and Utility Interfaces (15 Minutes)
A.
Offsite Agency Concept of Operations 1.
Coordination by utility 2.
Coordination by State VII.
Protective Action Decision Making (20 Minutes)
A.
Facility Role and Responsibility 1.
Technical / Rad Assessment 2.
Communication Offsite B.
State, County, Local Coordination 1.
Accident Notification System / Emergency Broadcast System Activation C.
Unique Actions 1.
Fast Moving Events 2.
School Districts 3.
Municipal Assistance 4.
EPZ VIII.
Facility Dose Assessment Situation (30 Minutes)
A.
Topography B.
Meterology C.
Effluent pathways and monitors D.
Met Instrumentation IX.
Facility Dose Assessment (2 Hours)
A.
Models and Types B.
Advantages / Limitations C.
Protocol D.
Interface with other organizations.
OFFICIAL RECORD COPY
.