January 20, 1987 DISTRIBUTION Docket No. 50-344 Docket File.
N. Thompson NRC PDR' J. Partlow Local PDR C. Vogan PD#3 Rdg.
T. Chan T. Novak ACRS(10)
Mr. William J. Lindblad E. Jordan B. Grimes President OGC Portland General Electric Company 121 S.W. Salmon Street Portland, Oregon 97204
Dear Mr. Lindblad:
SUBJECT:
GENERIC LETTER (GLI 83-28, ITEMS 3.1.3 AND 3.2.3 (POST-MAINTENANCE TESTING) i By letter dated November 4,1083, Portland General Electric Company (PGE) responded to several Items of GL 83-28, among them, Items 3.1.3 and 3.2.3 -
Post-Maintenance Testing. Supplemental information was provided in PGE letters dated October 13, and November 7, 1986.
Items 3.1.3 and 3.2.3 directed licensees to review their existing Technical Specifications for post-maintenance testing requirements that may degrade rather than enhance safety.
The staff has completed its review of PGE's responses and concludes that the subject has been adequately addressed, and is therefore acceptable. Our Safety Evaluation is enclosed.
Sincerely,
/s Terence L. Ch n, Project Manager Project Directorate #3 Division of PWR Licensing-A
Enclosure:
As stated cc: See next page PD#3 h PD#3'i CVogan Tchan:mak 1/p/87 1/2o/87 8701300024 870120 PDR ADOCK 05000344 P
~
Mr. William J. Lindblad Portland General Elctric Company Trojan Nuclear Plant cc:
Senior Resident Inspector U.S. Nuclear Regulatory Commission Trojan Nuclear Plant Post Office Box 0 Rainier, Oregon 97048 Robert M. Hunt, Chairman Roard of County Commissioners Columbia County St. Helens, Oregon 97501 William T. Dixon Oregon Department of Energy Labor and Industries Building Room 111 Salem, Oregon 97310 Regional Administrator, Pegion V U.S. Nuclear Regulatory Commission Office of Executive Director for Operations 1450 Maria Lane, Suite 210 Walnut Creek, California 94596
... - - -. -.