ML20212L229
| ML20212L229 | |
| Person / Time | |
|---|---|
| Site: | River Bend |
| Issue date: | 01/21/1987 |
| From: | Butler W Office of Nuclear Reactor Regulation |
| To: | Deddens J GULF STATES UTILITIES CO. |
| Shared Package | |
| ML20212L233 | List: |
| References | |
| NUDOCS 8701290380 | |
| Download: ML20212L229 (3) | |
Text
r January 21, 1987 DISTRIBUTION 6
Pleech Docket No. 50-458 NRC PDR M0'Brien LPDR ACRS(10)
PDf4 Rdg.
BTurovlin RBernero Mr. James C. Deddens Dewey,0GC Senior Vice President, (RBNG)
EJordan Gulf States Utilities BGrimes P. O. Box 220 JPartlow St. Francisville, LA 70775 NThompson ATTN: Nuclear Licensing SStern
Dear Mr. Deddens:
SUBJECT:
SAFETY EVALUATION REPORT - PRESERVICE INSPECTION PROGRAM The staff has reviewed your submittals of May 12, and November 19, 1986 regarding Revision 4 of the River Bend Station Preservice Inspection Program and Relief Request R 0012 (A to E) from certain requirements of the ASME Boiler and Pressure Vessel Code Section XI.
Based on the staff review and evaluation, the staff concludes that the public interest is not served by imposing certain provisions of the ASME Code that have been determined to be impractical. On the basis of granting relief from these preservice examination requirements, the staff concludes that the Pre-service Inspection program is in compliance with 10 CFR 50.55a(g)(3).
Enclosed is a Supplemental Safety Evaluation Report to Section 5.2.4 of the SER (attachment 1) and our technical evaluation of your relief request (attachment 2).
Please contact the project manager, Mr. Stern, for any further information on this matter.
Sincerely,
/s/
Walter R. Butler, Director BWR Project Directorate No. 4 Division of BWR Licensing
Enclosure:
As stated cc w/ enclosure:
Se ext page P 1/P PD#4/D S t4:rn:lb WButler l/t0/87 g /u/87 8701290380 870121 PDR ADOCK 05000458 G
/pa aso,o u
UN!TED STATES
[ 'p.,, ff,' g NUCLEAR REGULATORY COMMi3SION yjr y WASHINGTON, D. C. 20555
%) '.... /
January 21, 1987 Docket No. 50-458 Mr. James C. Deddens Senior Vice President, (RBNG)
Gulf States Utilities P. O. Box 220 St. Francisville, LA 70775 ATTN: Nuclear Licensing
Dear Mr. Deddens:
SUBJECT:
SAFETY EVALUATION REPORT - PRESERVICE INSPECTION PROGRAM The staff has reviewed your submittals of May 12, and November 19, 1986 regarding Revision 4 of the River Bend Station Preservice Inspection Program and Relief Request R 0012 (A to E) from certain requirements of the ASME Boiler and Pressure Vessel Code Section XI.
Based on the staff review and evaluation, the staff concludes that the public interest is not served by imposing certain provisions of the ASME Code that have been determined to be impractical. On the basis of grantino relief from these preservice examination requirements, the staff concludes that the Pre-service Inspection program is in compliance with 10 CFR 50.55a(g)(3).
Enclosed is a Supplemental Safety Evaluation Report to Section 5.2.4 of the SER (attachment 1) and our technical evaluation of your relief request (attachment 2).
Please contact the project manager, Mr. Stern, for any further information l
on this matter.
Sincerely, t
/&P Walter R. Butler, Director l
BWR Project Directorate No. 4 l
Division of BWR Licensing
Enclosures:
As stated cc w/ enclosures:
See next page i
l
Mr. James C. Deddens Gulf States Utilities Company River Bend Nuclear Plant cc:
Troy B. Conner, Jr., Esq.
Mr. J. E. Booker Conner and Wetterhahn Manaaer-River Bend Oversicht 1747 Pennsylvania Avenue, NW P. O. Box 2951
~
Washington, D.C.
20006 Beaumont, TX 77704 Mr. Edward Grant Director - Nuclear Licensing Mr. William H. Spell, Administrator Gulf States Utilities Company Nuclear Energy Division P. O. Box 2951 Office of Environmental Affairs Beaumont, Texas 77704 P. O. Box 14690 Baton Rouge, Louisiana 70898 Richard M. Troy, Jr., Esq.
Assistant Attorney General in Charge Mr. J. David McNeill, III State of Louisiana Department of Justice William G. Davis, Esq.
234 Loyola Avenue Department of~ Justice New Orleans, Louisiana 70112 Attorney General's Office 7434 Perkins Road Resident Inspector Baton Rouge, Louisiana 70808 P. O. Box 1051 St. Francisville, Louisiana 70775 H. Anne Plettinger 3456 Villa Rose Drive Gretchen R. Rothschild Baton Rouge, Louisiana 70806 Louisianians for Safe Energy. Inc.
1659 Glenmore Avenue Baton Rouge, Louisiana 70775 President of West Feliciana Police Jury Regional Administrator, Region IV P. O. Box 1921 U.S. Nuclear Regulatory Commission St. Francisville, Louisiana 70775 Office of Executive Director for Operations Mr. Frank J. Uddo 611 Ryan Plaza Drive, Suite 1000 Uddo & Porter Arlington, Texas 76011 6305 Elysian Fields Avenue l
Suite 400 Philip G. Harris New Orleans, Louisiana 70122 l
Cajun Electric Power Coop. Inc.
10719 Airline Highway P. O. Box 15540 Baton Rouge, LA 70895 l
l l
l
.-