A A Kfc P[,

'o,,

UNITED STATES 4,

NUCLEAR REGULATORY COMMISSION n

{

WASHINGTON, D. C. 20555

%,*****/

r"318 CG Docket No. 50-282 Mr. D. M. Musolf, Manager Nuclear Support Services Northern States Power Company 414 Nicollet Mall Midland Square, 4th Floor Minneapolis, Minnesota 55401

Dear Mr. Musolf:

SUBJECT:

PROJECTED VALUES OF MATERIAL PROPERTIES FOR FRACTURE TOUGHNESS REQUIREMENTS FOR PROTECTION AGAINST PRESSURIZED THERMAL SHOCK EVENTS-PRAIRIE ISLAND NUCLEAR GENERATING PLANT UNIT NO. 1 On June 23, 1986, the Commission issued a Safety Evaluation (SE) on

" Projected Values of Material Properties for Fracture Toughness Requirements For Protection Against Pressurized Thermal Shock Events" for Prairie Island Nuclear Generating Plant Unit No. 1.

Errors have been found on pages 2 and 3 of the SE.

Corrections are listed below and a reissue of the SE is enclosed.

1.

Top of page 2 - The number for " Utility Submittal" for "M (Margin, F) was left out.

The number should be "59."

Page 2 " Evaluation of the Calculated RT

" - The material properties 2.

ofthecontrollingmaterialandtheass$Natedmarginandchemistry factor were incorrect for copper and nickel.

The correct factor is 0.14 for copper (Cu) and 0.17 for nickel (Ni). This error causes the equation to change.

3.

Page 3 line 2 and line 4 from top of page "189.4 F" should be 3

"154.1 F" for the limiting circumferential weld material.

860easco97 a60818 DR ADocg 99999282 p

PDR

_2_

0 Pageg,)line3-thelargemarginbecomes"(145.9F)"insteadof 4.

110.6 F.

Please accept our apologies for any inconvenience these errors may have caused you.

Sincerely, s/

Dominic C. Dilanni, Project Manager Project Directorate #1 3

Division of PWR Licensing-A 3-

Enclosure:

'As Stated

?

ll PM/ PAD #1%4h P / PAD #::

8

Office:

LA/ PAD #1 Surname: PShuttlew DDilanni/lp Glear Date:

08//.F/86 08/ /f/86 08/lf/86

,