} Commonwealth Edison 72 West Adams Street, Chicago, Illinois
(
2 Address Reply to: Post Office Box 767
-sk / Chicago, Illinois 60690 0767 Pr(10RiiY ROUTING-First Second r~x October 7, 1986 A.__._fb-MP SGA ORS ML k _
PA0 Mr. James G. Keppler Regional Administrator Directorate of Inspection and Enforcement-U.S. Nuclear Regulatory Commission Region III 199 Roosevelt Road Glen Ellyn, Illinois 60137
Subject:
Byron Station' Radiological Environmental Monitoring Program NRC Dockets 50-454/455
Dear Mr. Keppler:
The Radiological Environmental Monitoring Program for Byron Station i
has been revised. During a recent in-house quality assurance audit, it was noted that the control dairy farm in the environmental program was improperly placed. The control dairy has been changed to adhere to the Radiological Environmental Technical Specifications. The new dairy, BY-17, is located in the least prevalent wind direction, approximately 9 miles from the station.
A copy of the revised Radiological Environmental Monitoring Program for Byron Station is attached.
If you have any questions concerning this change, please feel free to call.
Sincerely.
Irene M. John Nuclear Licensing Administrator enclosure cc:
R. E. Querio L. D. Butterfield J. c. Golden i
M. R. Di Ponzio EPG-06-RE-RADa7 e-6829E/49 0703060194 061007 f
R ADOCK 05000454 PDR OCT 2 01986
s in = = nadi m m ir.. m paooman. = - a.u acu V
Sampl3 tocation Collection Type of Frequency of Media code Site Frequency Analysis Analysis Ramerks 1.
Airborne By-01 Byron Cantinuous Gross beta Usekly Continuous sampling.
Particulates By-02 (a) Stillman Valley Operation ~
Sr-09,90 Quarterly On quarterly cougosite from each location By-03 uearsite-R For a Week Oasuna Isotopic guarterly on quarterly composite from each location By-04 Paynes Point Sy-05 Nearsite-S By-06 Oregon By-07(a)
Mt. Morris By-04(a) Leaf River Dy-21 Onsite W By-22 Ceco Property ESE sy-23 Onsite S By-24 Met Tenser 2.
Airborne same as 1.
Continuous I-131 weekly on all samples.
Iodine Operation For a Week 3.
Air Sampling Same as 1.
Test and weekly On all samplers.
Train Maintenance 4.
TLD Same as 1.
Quarterly Gamma guarterly Ttso sets at all AP locations. One set read 101-1,2 thru 116-1,2 Inner Ring quarterly. Second set road if requested 201-1,2 thru 216-1,2 Outer Ring by edison. At other locations, all sets read quarterly. Minimian of two TLDs per set.
5.
Surface By-09 voodland Creek weekly (if Gross beta weekly on all samples.
Water By-12 Oregon Pool Woodland Tritiusa guarterly On quarterly composite from each location of Bock River 4
By-13(a) acck River, creek is Gaumna Isotopic Munthly on monthly composite from each location.
Upstream floating)
St-89,90
- Quarterly on quarterly composite from each location.
6.
Cooling sy-10 Intake pipe weekly Gross beta weekly On all samples, water By-11 Discharge pipe Tritissa Mar.thly on suonthly composite front each location.
Gaume Isotopic Monthly on monthly composite from each location.
Sr-09,90 Monthly On monthly composite from each location.
Provided IT Station Personnel.
7.
Precipitation By-15 J.R. Reeverts Monthly Gross beta Monthly On all samples.
Pine Hill Dairy Trititua guarterly on quarterly ocuyosite from each location.
Gamma Isotopic guarterly on quarterly composite frosa each location.
By-16 Kenneth Durien St-09,90 guarterly on quarterly composite from each location.
Farm sy-17(a) Whitten Molsteins By-20 Ed Seabold Farm 05211/4 2
O O
O STRIEIARD BADIOLOGICM. ERIITORING PROGRAM, 3Y9018 STRTICW (continued)
Sample tocation Collection Type of Frequency of Media Code site Frequency Analysis Analysis Remarks-8.
Well Water-By-14 CBCO Property guarterly Ord s beta guarterly On all sag les.
offsite Tritium guarterly By-18 McCoy Farmstead Gamma Isotopic Quarterly St-89.90 guarterly 9.
Vegetables By-19-1 oregon stand Annually Gross beta Annually Four varieties from each location.
By-19-2 oregon stand Gamma Isotopic Annually as available at harvest. I 131 on St-89.90 Annually Leafy veg.
1-131 Annually 10.
cattle Feed Same as 7.
guarterly Gross beta guarterly Orass: Stummer - May to October and Grass Gamma Isotopic guarterly Feed:
Winter - November to April Sr-89.90 guarterly
- 11. Milk Same as 1.
Semi-stutthly Gamma Isotopic Semi-stutthly on all samples, when animals I-131 when animals on all samples.
are on pasture.
in pasture monthly at Monthly other other times.
times sr-89.90 Monthly
,k. times on all samples.
12.
Botton By-12 oregon Pool 3 times a year cross beta Sediments of Rock River
- a year By-13 Rcck River.
Gemma Isotopic On all samples.
Upstream
- 13. Aquatic Same as 12.
3 times a year Gross beta 3 times If available.
Plants Gemma Isotopic a year
- 14. Fish By-12 oregon Pool 3 times a year Orces beta 3 times on edible portions only.
of Rock River.
Gemma Isotopic a year At least two species.
Dounstrema sr-89.90 By-13 Rock River.
Upstream 0521X/5
s.
.,7 i
O O
- O SThamARD RADictXIGTCAL MONITORING PROMWE. SYROIf STATIObf j--
(continued...)
I Sample Location collection Type of Frequency of Media code Site Frequency Analysis Analysis 4
D i
15.
Dairy a.
Site boundary a.
Enumeration Annually.
During grazing season.
2 miles by a door-to-door or j
equivalent l
counting-technique b.
2 miles to 5 miles
- b.. Enumeration Annually During grazing season.
by using referenced j
information j
, from county 3
agricultural i
agents or 3l other.reli-able sources,
- c. At dairies listed in
- c. Inquire as to feinding Annually During grazing season.
Item 7 practices:
- 1) Posture only.
- 2) poed and chop only.
- 3) Posture and feed: if both, ask farmer to
- of
- l estimate fraction of i
food from pasture: <25%,
25-50%, 50-7%, or >1%.
(a) control (reference) locations.
]
All other Locations are Indicators.
i I
s i
1 1
os21x/6 l
1 i
l 1
)
.