ML20212F959

From kanterella
Jump to navigation Jump to search
Partially Withheld Insp Rept 50-458/86-31 on 860910 (Ref 10CFR73.21).Violation Noted:Inadequate Physical Barrier
ML20212F959
Person / Time
Site: River Bend Entergy icon.png
Issue date: 01/02/1987
From: Joseph Kelly, Yandell L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML20212F957 List:
References
50-458-86-31, NUDOCS 8701120225
Download: ML20212F959 (1)


See also: IR 05000458/1986031

Text

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____ .

.

.' .

'

APPENDIX B

U.S. NUCLEAR REGULATORY COMMISSION

REGION IV

NRC Inspection Report: 50-458/86-31 License: NPF-47

Docket: 50-V58

Licensee: GulfStatesUtilities(GSU)

P. O. Box 220

St. Francisville, Louisiana

Inspection Conducted: September 10, 1986

Inspector: aud 1/'2 /p 7

6 A. F. Kelly, Sent ir sical Se ity Dd te'

Inspector j

Angrwed: nul h3 /87

L. A~. Yahdell, Chief, Emergency Preparedness Date'

and Safeguards Programs Section

Inspection Sumary

Inspection Conducted September 10, 1986 (Report 50-458/86-19)

Areas Inspected: Reactive, announced inspection of physical barriers - vital

area, compensatory measures, and security organization management.

Results: Within the areas inspected, one violation was identified (inadequate

physical barrier - vital area, paragraph 2).

l

8701120225 870102

PDR ADOCK 05000458

G PDR

REMOVAL OF THE PAGES MARKED " SAFEGUARDS INFORMATION"

DECONTROLS THE REMAINDER OF THIS DOCUMENT.

--

- _ - _ _ _ _ _ _ _ _