September 22, 1999 1
l 1
MEMORANDUM TO: Cynthia A. Carpenter, Chief
)
Generic issues, Environmental, Financial j
and Rulemaking Branch 1
Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation
)
FROM:
Stewart L. Magruder, Project Manager,Q A.
Generic Issues, Environmental, Financial and Rulemaking Branch Division of Regulatory improvement Programs Office of Nuclear Reactor Regulation
SUBJECT:
SUMMARY
OF SEPTEMBER 8,1999, MEETING WITH THE NUCLEAR ENERGY INSTITUTE (NEI) REGARDING DESIGN BASIS INFORMATION l
On September 8,1999, representatives of the Nuclear Energy Institute (NEI) met with the staff of the Nuclear Regulatory Commission (NRC) at the NRC's offices in Rockville, Maryland. The purpose of the meeting was to discuss a letter from NEl dated August 17,1999, that forwarded industry proposals for guidance on design basis information as defined in 10 CFR 50.2. provides a list of attendees.
4 The staff began the meeting by distributing a list of discussion points that it hoped to cover during the meeting. This list is included as Attachment 2. The staff noted that the schedule for resolving this issue is contained in the staff's response to the Chairman's tasking memorandum of August 7,1998, and the latest version calls for a draft Regulatory Guide (RG) to be submitted to the Commission by October 31,1999. The staff stated that they believe that, with a few exceptions and clarifications, the draft RG will be able to endorse the NEl guidance document forwarded with the August 17,1999, letter. The staff and the NEl representatives agreed to use the discussion points as a means to focus discussion during the meeting and to summarize the points that may require exceptions at the end of the meeting.
The following is a summary of the consensus reached for each of the discussion poin
?fh}f :
General Guidance
- 1. NEl agreed to modify the guidance as proposed by the staff in Attachment 2.
,y
- 2. NEl believes that redundancy and diversity are only considered to be design bases functions p when they are specifically required to meet single failure criteria. To illustrate this point the Auxiliary Feedwater (AFW) System example in the NEl guidance was referenced. The
,f N
MD 9909280335 990922 NO (5 'I
~
.s PDR REVCP ERONUMRC PDR NN Yli J{sq
~
C. A. Carpenter l guidance lists the requirement for the AFW system to have sufficient redundancy to perform its safety function in the event of a single failure as the design basis function. However, it lists the fact that it is designed with two diverse power supplies and contains two motor driven pumps and one turbine driven pump as supporiing design information. The staff understood NEl's position but the staff considers the manner in which an SSC satisfies the regulatory requirements for redundancy and diversity to be a fundamental aspect of an SSC's design basis function as defined in 10 CFR 50.2
- 3. NEl confirmed that they intend for their guidance to be interpreted as limiting design bases values to those associated with design bases functional requirements. That is, design values such as AFW system design temperature and pressure not directly associated with the primary system functional requirements are not considered design bases values. The staff does not agree with this position. The staff believes that the design requirements associated with assuring that the SSC will not fail should be considered design bases. For example, the design requirements for assuring the AFW piping will not fail should be con'sidered design bases because the failure of the piping would prevent the AFW system from meeting its design basis functional requirement of providing water to the steam generators. The staff suggested that a structural integrity topical design basis may help in addressing this issue.
- 4. Consistent with the discussion above, NEl appears to believe that design values from codes should be considered design bases values only when they are associated with the functional requirements for the containment or the reactor coolant system. The staff considers design bases functions, as defined in 10 CFR 50.2, to include both active and passive functions for these (and other) SSCs and that controlling parameters for such functions may be derived from codes or standards. Consistent with the definition of design bases in 10 CFR 50.2, the staff does not expect the specific methodology presented in the code or standard to be part of the design bases, however, if a code or standard is required by regulation, or the licensee has committed to a particular code or standard, they are part of the facilities licensing bases. The staff considers licensee specified inputs, required for the application of the code, and code specified design values and constraints to be part of the design bases since they are " values chosen for controlling parameters,as reference bounds for design." For example, in the case of the ASME B&PV Code, licensee inputs such as pressure and temperature; or Code specified design values, such as, allowable stress or maintaining a cumulative usage factor (CUF) of less than 1, are considered to be part of the design bases. However, design outputs, such as pressure vessel wall thickness, obtained from the application of the ASME B&PV Code methodology and licensee specified design inputs would not be considered by the staff to be part of the design bases.
Specific Guidance l
- 1. NEl agreed to modify the first paragraph to make it clear that the boundir g conditions may include normal operation. They noted, however, that SSC design conditions specified for the l
normal operation are included as part of the design bases only if the normal operating mode of l
the SSCs provide a function required by regulation or is credited in the safety analyses. In this case, the function provided by the SSCs in the normal operating mode is the " reference bounds for design." The staff generally agrees with this statement, however, it pointed out that a number of safety analyses and normal operational functions are part of the design bases. For example, analyses for normal operational fuel rod growth, bow, fretting, or wear may result in l
D.
C. A. Carpenter t design basis functions or values. In addition, the normal systems that provide residual heat 1
removal or cooling water, in accordance with GDC requirements, also have design bases.
Relath.snio of 10 CFR 50.2 Desian Bases Functions to Licensina Basis and Part 50
. Reauirements l
.1. NEl believes that Appendix A requirements for fabrication, construction, testing, inspection and quality are not design bases per 10 CFR 50.2 because they are not requirements for the performance of intended functions. NEl believes that they are requirements and they provide j
assurance that functions can be performed but that they are not design bases. The staff l
disagreed with NEl's position. The staff believes that designing an SSC to ensure that it can be tested or inspected is a fundamental aspect of an SSC's design basis function. The staff does not consider the actual inspection or testing requirements to be part of the design bases.
- 2. NEl agreed to modify the last sentence and remove the reference to intended safety functions.
Relationshio of 10 CFR 50.2 Desian Bases to FSARs
- 1. NEl agreed to modify the last sentence to make it clear that, assuming each licensee has l-properly updated its UFSAR in accordance with the requirements of 10 CFR 50.71(e), no additionalinformation should be required to comply with this clarification of design bases.
Relationshio of 10 CFR 50.2 Desian Bases to Reaulatorv Guidance and NRC Commitments
- 1. NEl agreed to delete the first sentence of this section.
2.' The meeting participants agreed that design bases values may be derived from a RG. They L
also agreed that design bases functions are not derived from a RG but might be identified in i
one.
I l
. Relationship of 10 CFR 50.2 Desian Bases to Desian Inputs
- 1. NEl agreed to delete the last portion of the last sentence as follows:
Thus 10 CFR 50.2 design bases are a subset of the requirements that final detailed designs must meet. end are d;;;; net frem lnformatlen en how deo ga requlremente are met.
In summary, the meeting participants concluded that there is still disagreement between the staff and NEl on three issues. The first issue is whether the design bases should include inforrr ation that provides assurance that an SSC will be able to perform its design basis function when required. NEl believes that the design bases should be limited to that information that describes the primary (active) functions of SSCs and the values associated with those functions. The staff, however, believes that additional information is required because design bases functions include those functions (active and passive) required to assure
. that the primary functions can be performed. The second issue is how much information related to redundancy and diversity should be considered design bases. The staff considers L
f
~
n r
o, C. A. Carpenter the manner in which requirements for redundancy and diversity are satisf'ied to be part of the design bases. The third issue is whether or not designing to permit inspection and testing is part of the design bases. The staff stated that it would proceed with preparing a draft RG for public comment that endorses the NEl guidance.
Attachments: As stated cc w/atts: See next page DISTRIBUTION: See next page G:\\RGEB\\slm1\\msum0908.wpd ff
- see previous concurrence
//,
OFFICE RGEB DE:EMEB DSM:Si3XB SChk NAME SMagruheIbf
- Elmbro JWhl Mk[leMcz DATE 09/ F1/99 09/15/99 09/ El /99 E d9/2-[ /99 OFFICIAL RECORD COPY i
l l
4 l
l l
(:
e C.'A. Carpenter 4-the manner in 'which requirements'for redundancy and diversity are satisfied to be part of the design bases. The third issue is whether or not designing to permit inspection and testing is part of the design bases. The staff stated that it wculd proceed with preparing a draft RG for public comment that endorses the NEl guidance.
Project No. 689 Attachments: As stated.
cc w/atts: See next page
).
Nuclear Energy Institute Project No. 689 cc:
Mr. Ralph Beedle Ms. Lynnette Hendricks, Director Senior Vice President Plant Support and Chief Nuclear Officer Nuclear Energy institute Nuclear Energy Institute Suite 400 Suite 400 1776 i Street, NW 1776 i Street, NW Washington, DC 20006-3708 Washington, DC 20006-3708 Mr. Alex Marion, Director Mr. Charles B. Brinkman, Director Programs Washington Operations Nuclear Energy Institute ABB-Combustion Engineering, Inc.
Suite 400 12300 Twinbrook Parkway, Suite 330 1776 l Street, NW Rockville, Maryland 20852 Washington, DC 20006-3708 Mr. David Modeen, Director Engineering Nuclear Energy Institute Suite 400 1776 i Street, NW Washington, DC 20006-3708 Mr. Anthony Pietrangelo, Director Licensing Nuclear Energy Institute Suite 400 1776 i Street, NW Washington, DC 20006-3708 Mr. H. A. Sepp, Manager Regulatory and Licensing Engineering Westinghouse Electric Cortipany P.O. Box 355 Pittsburgh, Pennsylvania 15230-0355 Mr. Jim Davis, Director Operations Nuclear Energy Institute Suite 400 1776 l Street, NW Washington, DC 20006-3708
^
NEl/NRC DESIGN BASIS INFORMATION GUIDANCE MEETING September 8,1999 List of Attendees NAME ORGANIZATION Tony Pietrangelo NEl Russ Bell NEl Scott Newberry NRC/NRR Tom Scarbrough NRC/NRR Stu Magruder NRC/NRR Frank Akstufewicz NRC/NRR Christopher Jackson NRC/NRR Gene Imbro NRC/NRR Dave Fischer NRC/NRR Eric Weiss NRC/NRR Bill Reckley NRC/NRR Cindi Carpenter NRC/NRR Om Chopra NRC/NRR Jack Smith Virginia F'wer Ken Hutko PSE&G Ben George Southern Nuclear Nancy Chapman SERCH/Bechtel Roger Huston Licensing Support Services Don Palmrose NUS-IS Jenny Weil McGraw-Hill
DESIGN BASES PUBLIC MEETING 9/8/99 DISCUSSION POINTS Schedule:
Draft RG to Commission by 10/31/99 ACRS brief 10/1/99 CRGR brief 10/12/99 General Guidance
- 1. Can the guidance on design bases functions be modified to read as follows?
(1) Functions required to meet regulations, license conditions, orders or technical specifications, or (2) functions credited in safety analyses to meet NRC requirements.
- 2. Are redundancy and diversity design bases functions?
- 3. Are design bases values limited to those associated with design bases functional requirements? Use AFW design pressure and temperature as example.
l
- 4. Should design values from codes (ASME, IEEE, etc.) be considered design bases values?
Soecific Guidance
- 1. Can the discussion of normal operation in paragraph a) be clarified?
l Relationshio of 10 CFR 50.2 Desian Bases Functions to Licensina Basis and Part 50 l
Reauirements
- 1. Appendix A requirements for fabrication, construction, and quality are not design bases, l
however, requirements for testing and inspection may be.
l
- 2. Can the reference to intended safety functions in the last sentence be changed?
Relationshio of 10 CFR 50.2 Desian Bases to FSARs l
l
- 1. The last sentence is causing some confusion. Can it be deleted or modified?
Relationship of 10 CFR 50.2 Desian Bases to Reaulatory Guidance and NRC Commitments
- 1. The first sentence is confusing. Can it be deleted or modified?
- 2. Can design bases functions also be found in a RG?
Relationshio of 10 CFR 50.2 Desian Bases to Desian Inouts
- 1. Are design bases distinct from information on how design requirements are met?
h
b>f dTcLL d d L
9l)2/M Distribution: Mtg. Summary w/ NEl on Design Basis information Dated l