Text
" '
6
~
i DuxE POWER GOMPANY P.O. Itox 33189 s
CHAMLOTTE, N.C. 28242 HAL H. TUCKER Tut.nenoxx 3
vnos resessent (704) 073-4531 wwasam reanniorsom l',,
December 29, 1986 U. S. Nuclear Regulatory Coinnission Attention: Document Control Desk Washington, D. C.
20555 i
Ret Catawba Nuclear Station, Unit 1 Docket No. 50-413 Gentlemen:
Pursuant to Technical Specification 3.3.3.9 and 6.9.2, please find attached a Special Report concerning the inoperability of a channel of the Loose Parts Monitoring System.
Very truly yours, B2LJ kr l
Hal B. Tucker RWO/54/slb Attachment set Director Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D. C.
20555 e
NRC Resident Inspector Catawba Nuclear Station Dr. J. Nelson Grace, Regional Administrator U. S. Nuclear Regulatory Constission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 G701050200 861229
[
PD3 ADOCK 05000413 q
e PDR g-l t
SPECIAL REPORT LOOSE PARTS MONITOR CHANNEL #8 INOPERABLE On November 17, 1986 channel f8 (Steam Generator D) of the Unit 1 Vibration and Loose Parts Monitor System was declared inoperable. A Work Request was written to repair the accelerometer. The repair will be carried out during a future outage.
Since the channel has been inoperable more than 30 days this is reportable pursuant to Technical Specification 3.3.3.9.