NUCLEAR REGULATORY COMMISSION Request for Comment on -

Proposed Compatibility Designation Change to 10 CFR 61.16(b)(2) and on Draft Emplacement Criticality Guidance for Low-Level Waste

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) is requesting public comment as to whether the compatibility designation of 10 CFR 61.16(b)(2) should be changed. The compatibility designation relates to the extent which an Agreement States regulations must be compatible with NRC requirements. The section of 10 CFR Part 61 under consideration requires low-level waste (LLW) disposal facility licensees who receive and possess special nuclear material (SNM) to describe proposed procedures to avoid accidental criticality for storage of SNM waste prior to disposal and after disposalin the ground. In addition, NRC also is requesting comment on draft guidance on emplacement criticality at LLW disposal facilities.

A copy of the draft guidance (NUREG/CR-6626, Emplacement Guidance for Criticality Safety in Low Level Waste Disposal) can be obtained from the Internet at "http://techconf. lint. gov."

BACKGROUND Section 274 of the Atomic Energy Act of 1954 (AEA), as amended, provides a statutory basis for discontinuance by the NRC, and the assumption by the State, of regulatory authority for byproduct material, source material, and SNM in quantities not sufficient to form a critical mass. As stated in the Commission's Policy Statement on Adequacy and Compatibility of Agreement State Programs (62FR46517, September 3,1997), NRC and Agreement States have the responsibility to ensure that there is adequate protection of public health and safety and that radiation control programs are administered consistent and compatible with NRC's program.

Quantities of SNM not sufficient to form a critical mass are defined in 10 CFR 150.11 as enriched uranium not exceeding 350 grams, uranium-233 not exceeding 200 grams, plutonium not exceeding 200 grams, or mixtures where the sum of the fractions is less than unity. These 9909210249 990909 PDR WASTE WPt-4 PDR

d 2

quantities of SNM can be regulated by the Agreement States. In both Agreement States and non Agreement States, an NRC license is required for persons who possess quantities of SNM in excess of the Section 150.11 limits. As it pertains to disposal facilities, the possession limits apply t'o material above-ground. Once the SNM waste is disposed of (i.e., placed in the j

- disposal trench), SNM waste is not restricted by the Section 150.11 limits.

Currently 10 CFR 61.16 is not a regulation required for Agreement State adoption, therefore, there is no equivalent Agreement State regulatory requirement for Agreement State licensees of existing or future LLW facilities to follow the equivalent of 61.16(b)(2) and to evaluate emplacement criticality safety. This section of 10 CFR Part 61 requires LLW disposal facility licensees who receive and possess SNM waste to describe proposed procedures to avoid accidental criticality for storage of SNM waste prior to disposal and after disposal in the ground. Although the SNM mass limits in Part 150 restrict above-ground possession and ensure criticality safety above-ground (during receipt and storage), there is no equivalent mass restriction or other controls which limit the amount of SNM waste that can be placed in a disposal trench; and therefore, the question of criticality safety below-ground after disposalis left open. A technical basis for NRC's concern regarding emplacement criticality safety is presented in the DISCUSSIONsection of this Federal Reaister notice.

LLW containing SNM is currently disposed of at three facilities: Barnwell, South Carolina; Hanford, Washington; and Clive, Utah. All of these facilities are licensed by Agreement States.

From the 1970's to 1997, NRC licensed the Barnwell and Hanford facilities under 10 CFR Part 70, to receive, possess, store, and dispose of kilogram quantities of SNM waste. In 1997, i

these facilities requested that the SNM possession limits be reduced to the Section 150.11 limits, and that NRC licenses be transferred to the respective Agreement States. These actions have been taken for both (Barnwell and Hanford).

The State of Washington incorporated NRC criticality controls for emplaced waste in license l

conditions in its Hanford license. Although not in the license, the State of South Carolina has 1

required the licensee to implement the SNM waste emplacement procedures that address criticality safety. These procedures cannot be changed by the operator without State approval.

NRC recently issued an Order to Envirocare that exempts Envirocare from the licensing requirements in 10 CFR Part 70 for possession of SNM waste at concentration limits in the Order, which ensures criticality safety. The conditions of the Order have been incorporated into the State of Utah license.

\\

1 If NRC changes the compatibility designation for Part 61.16(b)(2), then LLW disposal facility licensees would be required to develop procedures for avoiding accidental criticality, during both storage of SNM waste prior to disposal and after disposal in the ground. These procedures would then be reviewed and approved by Agreement State staffs. Given that licensees and Agreement State staffs may not have experience in criticality safety, NRC has developed guidance that could be used by licensees and Agreement State staffs to demonstrate compliance with Part 61.16(b)(2). A summary of this draft guidance and how the guidance is envisioned to be used are provided in the DISCUSSION section of this Federal Reaister notice.

4 DISCUSSION This section presents a discussion of the following: (1) the technical basis for requiring emplacement criticality controls; (2) NRC staff's assessment of the compatibility designation for J

10 CFR 61.16(b)(2); (3) a summary of the draft guidance; (4) the envisioned implementation if the compatibility of 61.16(b)(2) is changed; and (5) NRC staff's assessment of potential resource impacts on Agreement States.

Technical Basis Spontaneous nuclear fission occurs naturally in a very small percent of radioactive decays in some elements. When fission occurs, neutrons are emitted, along with fission fragments (e.g., cesium and strontium). The neutrons that are produced may be absorbed by an atom without causing a fission, may be absorbed by an SNM atom and cause a fission, or may not collide with any atoms. SNM (i.e., uranium-235, uranium-233, and plutonium) is unique from most materials in that a fission, not associated with a radioactive decay, can occur when a neutron collides with its nucleus. In natural materials such as soils containing natural uranium, neutrons produced by spontaneous fission are typically absorbed by uranium 238 atoms and do not collide with a uranium-235 atom possibly resulting in fission. Criticality is a chain reaction I

where large numbers of neutrons are produced, and can occur when sufficient SNM is present.

For a criticality to occur, special conditions involving a number of factors must occur.

Important factors that affect the criticality safety of a LLW disposal site are: (1) the isotope; l

4

(2) enrichment; (3) mass; (4) concentration; and (5) presence of neutron moderating and absorbing materials. Each of these is discussed below. (Following this is a discussion of these factors relative to possible scenarios).

(1) Isotooe: The SNM isotopes present in LLW are dependent on the waste stream. The vast majority of SNM waste is generated from the production of nuclear fuel for nuclear power plants and from LLW generated by nuclear power plants. Of the SNM isotopes, uranium-235 is the most common. Large quantities of plutonium and uranium-233 (the other SNM isotopes) are not present in the commercial waste. However, these materials are present in Department of Energy (DOE) facility waste, and some DOE waste is being shipped to commercial LLW disposal facilities.

(2) Enrichment: Enrichment is a ratio of the weight of uranium-235 to the weight of the total uranium and is commonly expressed as a percent. Natural uranium, found in most soils, has an average enrichment of 0.71 percent. In order to be used as nuclear fuel, natural uranium must be enriched in uranium-235. Most nuclear fuel is enriched to less than 6 percent, which is considered low-enriched uranium; however, some nuclear fuel for special reactors such as those in naval vessels is enriched to much higher values, which is considered high enriched uranium. At enrichments less than about 0.96 percent, criticality is not possible regardless of the mass or concentration. As enrichment increases, criticality becomes a greater concern. Although most of the SNM waste contains low-enriched uranium, some waste contains high-enriched uranium.

(3) Mass: As discussed above, disposal facilities that are licensed by Agreement States and do not have an NRC license are subject to the SNM possession limits in Part 150 for above ground possession. These limits are based on a fraction of the minimum mass required to achieve a criticality. Under these limits, there is simply not enough SNM to cause a criticality regardless of the enrichment or concentration. However, these limits have been applied to above-ground possession, and SNM waste that has been disposed of is no longer be subject to these limits. Historic records at disposal sites indicate that some disposal units (trenches) have a mass of uranium-235 in the hundreds of kilogram range. Therefore, it is reasonable to assume that large masses of SNM waste will be disposed of in disposal units in the future.

In some cases, the mass of SNM in individual packages is limited by the requirements in Part 71 (Packaging and Transportation of Radioactive Material). The majority of SNM waste shipped to a LLW disposal facility is transported under 10 CFR 71.53 as " fissile exempt." This

I means it does not have to comply with the fissile material package standards in Sections 71.55 and 71.59. In order to be " fissile exempt", the quantity of unusual moderators (beryllium, graphite,' or deuterium) is limited as is either the mass per package, the amount of moderator

-(water), concentration, enrichment, or mass per consignment. For example, SNM waste can be shipped as fissile exempt, if it contains no more than 15 grams of SNM per package. However, some generallicenses in Part 71 allow for SNM waste to be shipped at higher masses per package. For example,10 CFR 71.22 allows up to 500 grams per shipment, which could be in a i

single container, provided unusual moderators are limited to 0.1 percent of the mass of the fissile material. This generallicense does not restrict concentration or enrichment. Therefore, mass cannot be eliminated as a factor of concern based solely on packaging and transportation regulations. As mass increases, criticality becomes a greater concern.

(4) Concentration: In some cases, the concentration of SNM received by a LLW disposal facility is limited by the requirements in Part 71. While significant quantities of SNM waste can be shipped under a number of generallicenses, the majority of SNM waste shipped to a LLW disposal facility is transported as " fissile exempt". As noted above, in order to be " fissile exempt", the quantity of unusual moderators (beryllium, graphite, or deuterium) is limited, as is either the mass per package, the amount of moderator (water), the concentration, the enrichment, or the mass per consignment. For example, SNM waste can be shipped as fissile exempt,if it contains no more than 5 grams of SNM in any 10 liter volume. However, some general licenses in Part 71 allow for SNM waste to be shipped at higher concentrations per package. Therefore, concentration cannot be eliminated as a factor of concern based solely on packaging and transportation regulations.

)

(5) Presence of neutron moderator and absorbers: Neutrons that are produced during a fission have a relatively high energy and are termed " fast" neutrons. Moderators are materials that reduce the energy, or slow neutrons. This is important because uranium-235 is much more

]

likely to be fissioned by slow neutrons than by fast neutrons. Therefore, the presence of moderator materials can increase the criticality concern. Elements such as hydrogen and carbon are particularly Good moderators. Because water is abundant and is a very efficient moderator, assuming water is present is a common approach in evaluating the criticality significance of situations. However, there are certain materials such as beryllium, graphite, and deuterium that are more efficient moderators than water. These material are commonly termed

" unusual" moderators.

3

Absorbers are materials that absorb or capture neutrons. Because capturing neutrons prevents those neutrons from possibly causing a fission, the presence of absorber materials will decrease the criticality concern. Most materials act both as a moderator and an absorber to varying degrees.

In some cases the presence of moderator material is limited by the requirements in Part 71. However, this is not always the case, it is reasonable to assume that moderators, such as water, will be present in the waste. In analyzing the criticality hazard of waste at LLW disposal facilities, it is conservative to assume that moderators will be present in optimal amounts. The presence of absorber materials is not limited by regulations. These materials, such as iron, calcium, etc., are present in LLW and in the waste containers. However, the amount and distribution of absorbers cannot be assured, so they are typically omitted in analyzing criticality hazards. For example, although a steel drum acts as an absorber, the drum will corrode within tens of years and can no longer be depended on to contain the waste and act as an absorber.-

Possible Scenarios l

In order for a criticality to occur, several of the above factors m'.;st be above certain values.

For instance, a criticality cannot occur if the mass of the SNM is below a certain value regardless of the enrichment or concentration. A criticality cannot occur if the concentration of the SNM is below a certain value regardless of the enrichment or mass. A criticality cannot occur if the enrichment is below a certain value regardless of the mass or concentration.

Considering what can be controlled by Parts 71 and 150, several scenarios can be

)

postulated. For waste shipped as " fissile exempt", concentrations can be limited to 5 grams of

)

SNM per 10 liters. This translates to 104 grams of enriched uranium for a typical waste container (i.e.,55-gallon drum). In addition, under the fissile exemption unusual moderators are limited. Assuming a density of waste of 68 pounds per cubic foot, this concentration (4.6E-4 gram of uranium-235 per gram of waste)is smaller than the allowable operational concentration limit in the draft guidance (NUREG/CR-6626, Emplacement Guidance for Criticality Safety in Low-Level Waste Disposal) and therefore is considered safe. The limits in the draft guidance have been developed considering that absorbers are not present and that moderation with water is optimal to maximize the possibility of fissions.

For waste that does not meet the fissile exemption criteria, concentration, enrichment, and mass are not controlled. Given that disposal facilities licensed by Agreement States can only possess 350 grams, a package containing 350 grams of highly enriched uranium could be shipped to a disposal facility, Using the example of waste shipped in 55-gallon drums with a waste density of 68 pounds per cubic foot, the uranium-235 concentration is 1.5E-3 gram of uranium-235 per gram of waste. This concentration exceeds the limit for high enriched uranium in the draft guidance (8.3E-4 gram U-235/ gram of waste for a 10-foot high disposal unit). While a single container would not represent a criticality concern, an array of such drums could represent a criticality concern.

Using the criticality calculations in NUREG/CR-6505 Volumes 1 and 2, "The Potential for Criticality Following Disposal of Uranium at Low-Level Waste Facilities," an array of low-enriched uranium (10 percent enrichment) drums stacked more than 15 feet high could pose a criticakty concern. An array of high-enriched uranium (100 percent enrichment) drums stacked more than 11 feet high could pose a criticality concern. Trenches at burial sites are deeper than 15 feet. These calculations assume optimal water moderation and no absorbers.

Although there is significant uncertainty associated with a waste facility receiving and disposing of numerous drums containing large amounts of SNM, there are no regulatory limitations to preclude this situation.

NRC staff Assessment of Compatibility Desianation At the time the compatibility designations were originally selected for Part 61 (1983), the NRC directly regulated SNM at LLW disposal facilities. Becuase the NRC is responsible for SNM in greater than critical mass quantities and regulated SNM at LLW disposal facilities, there was no need for Agreement States to adopt these requirements. These requirements were designated "Not Required for Compatibility." As noted above, LLW disposal facilities reduced their SNM possession limits to those provided in 10 CFR 150.11 (350 grams or less). This authority was assumed by the respective Agreement State; thus, the NRC no longer directly regulates SNM at LLW disposal facilities, including the authority to administer waste emplacement criticality controls. Therefore, the NRC is considering changing the compatibility designation of Part 61.16(b)(2) to ensure these safety measures are applied in the disposal of SNM.

i i

i

8 NRC staff used the procedures outlined in Management Directive 5.9," Adequacy and Compatibility of Agreement State Programs," and concluded that the compatibility designation for Section 61.16(b)(2) should be revised from category "Not Required for Compatibility", to category " Health and Safety". " Health and Safety" applies to activities that could result directly in an exposure to an individualin excess of basic radiation protection standards,if the essential objectives of the provision were not adopted by an Agreement State. If an inadvertent criticality were to occur at a LLW disposal facility, workers could receive doses in excess of the 10 CFR Part 20 limits. Under the " Health and Safety" category, Agreement States that have currently operating LLW disposal facilities and those States which will be establishing LLW disposal facilities in the future, would need to adopt legally binding requirements that encompass the essential objectives of 10 CFR 61.16(b)(2) within three years of the change of designation in compatibility. This requirement would continue to be designated as "Not Required for Compatibility," for other Agreement States.

Summarv of Draft Emplacement Criticality Guidance The draft guidance provides a general approach to emplacement criticality safety. Five different SNM isotopic compositions were studied: uranium-235 at 10 and 100 percent enrichment; uranium-233; plutonium-239; and a mixture of plutonium-239, -240, and -241.

Three different graded approaches are presented. The first graded approach is the most conservative, and can be used easily for facilities that dispose of very low levels of SNM, or dispose of material with a low average enrichment. This approach relies on the calculation of average areal density, or grams of SNM per square foot, or on the average enrichment of SNM.

The area over which averaging may be performed also is specified, but the emplacement depth and concentration are not limited.

The second graded approach relies on limiting the average concentration by weight of SNM in the waste, and on limiting the depth of the emplacement. This method may be useful for facilities that emplace somewhat higher areal densities of SNM, but which do not use vaults or segmentation in the disposal emplacement.

The third graded approach relies on limiting the average concentration by weight of SNM in the waste, and on the presence of segmenting barriers, such as vaults, that will prevent movement of SNM waste from one side of the barrier to the other. This method may be useful for facilities that use concrete vaults in their disposal areas.

l Envisioned lmolementation of Guidance and Chanae in Compatibility if the compatibility designation of 10 CFR 61.16(b)(2) were changed from "Not Required for Compatibility" to " Health and Safety", Agreement States would have three years to implement regulations or other legally binding requirements compatible with 61.16(b)(2). As noted earlier, J

the States of Washington and South Carolina currently have emplacement criticality controls.

The compatibility change will assure that future LLW disposal facilities in Agreement States will

)

i i

have criticality safety controls for emplaced SNM waste, After these legally binding requirements have been implemented, the Agreement State regulatory program would require their licensees (disposal facility operators) to prepare and submit information demonstrating compliance with their equivalent of 10 CFR 61.16(b)(2).

To assist the States and licensees, NRC has prepared emplacement criticality safety guidance. Licensees would review the types of waste and disposal operations and determine which of the graded approaches in the guidance were appropriate for its facility. For each of the graded approaches, the NRC draft guidance includes criticality safety limits and a description of how to calculate the limits based on readily available information. The draft guidance also indicates the type of procedures that would need to be developed for each of the graded approaches. This guidance would serve as a technical basis for preparing the license amendment requests submitted to the Agreement States.

The Agreement State regulator would then review this amendment request and modify the license as appropriate. Again, the guidance would serve as the technical basis for the State regulator.

NRC Staff Assessment of Potential Resource lmoact on Aareement States NRC staff has estimated the potential resource impacts on Agreement States to implement a change in the compatibility of 10 CFR 61.16(b)(2). As indicated above, the first step would be to modify its regulations or other legally binding requirements to be compatible with 61.16(b)(2).

We consider that only a minor modification would be necessary to the existing Agreement State Part 61 equivalent regulations, or that the compatibility change could be administered through other legally binding requirements. We estimate that this will take four to six-State staff weeks.

The next step of an Agreement State would be to review the licensee's amendment request and/or procedure changes. We estimate that this will take two-State staff weeks. Some

10-additional effort would be required for inspection of the facility; however, this effort is not estimated to be significant.

1 DATES Submit comments by (30 days from the date of this notice) to Tim Harris, Mail Stop T7-

]

F27, Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory Commission, Washington DC,20555. Comments received after this date will be considered, if it is practical to do so, but assurance of consideration can only be given to comments received on or before this date.

CONTACT For further information or to obtain a copy of the draft guidance (NUREG/CR-6626, Emplacement Guidance for Criticality Safety in Low-Level Waste Disposal) contact Mr. Tim Harris, Mail Stop T7-F27. Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory Commission, Washington DC,20555, by telephone, at (301) 415-6613 or by Internet e-mail at TEH @ NRC. GOV.

Dated at Rockville, Maryland this day of $wh 1999.

FOR THE NUCLEAR REGULATORY COMMISSION l

x.

M/

t Daniel M. Gillen, Acting Chief Uranium Recovery and Low-Level Waste Branch Division of Waste Management Office of Nuclear Material Safety and Safeguards

)

I

MEMORANDUM TO: David Meyer, Chief

~

Rules and Directives Branch Division of Administrative Services Office of Administration FROM:

John T. Greeves, Director Division of Waste Management Office of Nuclear Material Safety and Safeguards

SUBJECT:

REQUEST FOR COMMENT ON PROP ED COMPATIBILITY DESIGNATION CHANGE TO 10 CFR 1.16(b)(2) AND ON DRAFT EMPLACEMENT CRITICALITY GUI ANCE FOR LOW-LEVEL WASTE Attached please find one signed original of the ubject Federal Reaister notice for your transmittal to the Office of the Federal Register for p lication. Also, attached are five copies of the signed notice and a 3.5" diskette with the notic in Wordperfect.

Attachments: As stated

Contact:

Tim Harris, NMSS/DWM (301) 415-6613 DISTRIBUTION:

Central File LLDP r/f NMSS r/f D M r/f JHolonich PLohaus PUBLIC JCopeland DOCUMENT NAME:s:\\dwm\\lldp\\teh\\ itdft2.wpd To r:c:lve a copy of this document in small box on "

C:" line enter: "C" = Copy without attachment / enclosure: "E" = Copy with r tt chment/ enclosure: "N" = No copy

'sEE PREVloUs CONCURRENCE

/

\\

fpFC LLDP' LLDP*

GC#

OSP

,p]i7)) h URLL i

!JLieberman h

AME THarris RNelson PL u

m rme JG ves DATE 8/23/99 8/23 /

4(/'h99 8fl@99 g/Z'99 8/L1/99

/9\\

8/

pF OFFICIAL RE RD COPY ACNW: YES

_X_ NO _

Category: Proprietary _ or CF Only _

IG : YES X NO LSS : YES NO X elete file after distribution: Yes No X l

l 1

pames Ltberman - crifi2.wpd

((_

~~[ ] ))'] ] ~ [ Pdg @

~'

~

d MEMORANDUM TO: David Meyer, Chief Rules and Directives Branch Division of Administrative Services Office of Administration FROM:

John T. Greeves, Director Division of Waste Management Office of Nuclear Material Safety and Safeguards

SUBJECT:

REQUEST FOR COMMENT ON PROPOSED COMPATIBILITY DESIGNATION CHANGE TO 10 CFR 61.16(b)(2) AND ON DRAFT EMPLACEMENT CRITICALITY GUIDANCE FOR LOW-LEVEL WASTE Attached please find one signed original of the subject Federal Register notice for your transmittal to the Office of the Federal Register for publication. Also, attached are five copies of the signed notice and a 3.5" diskette with the notice in Wordperfect.

Attachments: As stated

Contact:

Tim Harris, NMSS/DWM (301) 415-6613 D;CTRIBUTION:

Central File DCB r/f NMSS r/f DWM r/f JHolonich PLohaus PUBLIC JCopeland DOCUMENT NAME:s:\\dwm\\lldp\\teh\\critdft2.wpd To receive a copy of this document in small box on "OFC:" line enter: "C" - Copy without attachmentlenclosure; "E" = Copy with attachment / enclosure: *N" - No copy

'sEE PREVIOUS CONCURRENCE OFC LLDP* l LLDP* I OGC l

OSP l DCB l

URLL l DWM l NAME THarris RNelson JLieberman PLohaus LCamper JSurmeier JGreeves DATE 8/23/99 8/23 /99 6$/1/9S 8/ /99 8/ /99 8/ /99 8/ /99 OFFICIAL RECORD COPY f ACNW: YES

_X_ NO _

Category: Pro ~prietary _ or CF Only _

IG : YES X NO LSS : YES NO X Delete file after distribution: Yes No X 1