Application for Amends to Licenses NPF-9 & NPF-17,revising Tech Specs to Incorporate Revised Steam Generator Plugging criteria.WCAP-11224 & WCAP-11225 Re Tubesheet Region Plugging encl.WCAP-11224 Withheld (Ref 10CFR2.790)
ML20212B858
Person / Time
Site: McGuire, Mcguire  
Issue date: 08/05/1986
From: Tucker H
DUKE POWER CO.
To: Harold Denton, Youngblood B
Office of Nuclear Reactor Regulation
Shared Package
ML19292F701 List:
References
NUDOCS 8608070254
Download: ML20212B858 (36)


Text

f-DUKE POWER GOMPANY P.O. BOX 33189 CHAMLOTTE, N.O. 28242 HALH. TUCKER TE LEPHONE

)

v3cm pmReneENT WUCLEAR Peopt'CTION August 5,1986 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Comunission Washington, D.C.

20555 ATTENTION:

Mr. B.J. Youngblood, Director PWR Directorate No. 4

Subject:

McGuire Nuclear Station, Units 1 and 2 Docket No. 50-369, 50-370 Steam Generator Tube Plugging Criteria

Dear Mr. Denton:

i By letter dated June 24, 1986 and supplemented July 1, 1986 and July 23, 1986, Duke Power proposed changes to the steam generator tube plugging criteria in the McGuire Nuclear Station Technical Specifications initially to incorporate the P*

criteria for steam generator (S/G) tube plugging, then to base the proposal on the F* criterion af ter discussions between our respective staffs. Accordingly, some changes to the proposal are necessary.

i Attachment I contains the proposed changes to the Technical Specifications to base the plugging criterion on F*.

While the proposal does not contain a requirement to plug indications above F*, Duke Power intends to plug tubes with primary water stress corrosion cracking (PWSCC) indications above F* until this type of degra-dation can be more accurately characterized and sized by eddy current testing (ECT). Additionally, a footnote is added to specify a time limit on the appli-cation of F*.

This time period expires ninety days af ter startup following the fifth refueling outage for each unit and is to alleviate staff concerns of long term application without further data while allowing operation for two more cycles on Unit 1, three cycles on Unit 2 in order to allow continued operation while j

gathering further data on PWSCC, and that any subsequent changes will not be on an

]

expedited basis. contains the Westinghouse report to answer the staff concerns as addressed in the July 24, 1986 letter to Mr. H.B. Tucker including test data.

Enclosed are:

1.

Two copies of WCAP-11224 entitled, "Tubesheet Region Plugging Criterion For the Duke Power Company McGuire Nuclear Station Units 1 and 2 Steam Genera-h00I tors" (Proprietary).

'I EG+G i

8600070254 860805 j

PDR ADOCK 05000369 P D$-

D N

P PDR gg

(

Mr. Harold R. Denton, Director August 5, 1986 Page 2 2.

Two copies of WCAP-11225 entitled, "Tubesheet Region Plugging Criterion For the Duke Power Company McGuire Nuclear Station Units 1 and 2 Steam Genera-tors" (Non-Proprietary).

Also enclosed is a Westinghouse Application For Withholding, CAW-86-065. Accom-panying Affidavit, and Proprietary Information Notice (Attachment 3).

As this submittal contains information proprietary to Westinghouse Electric Corporation, it is supported by an affidavit signed by Westinghouse, the owner of the information. The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specifi-city the considerations listed in paragraph (b)(4) of Section 2.790 of the Com-mission's regulations.

Accordingly, it is respectfully requested that the information which is proprie-tary to Westinghouse be withheld from public disclosure in accordance with 10CFR Section 2.790 of the Commission's regulations. Correspondence with respect to the proprietary aspects of the Application for Withholding or the supporting Westing-house affidavit should reference CAW-86-065 and should be addressed to R.A.

Wiesemann, Manager Regulatory and Legislative Affairs, Westinghouse Electric Corporation, P.O. Box 355, Pittsburgh, Pennsylvania 15230.

This submittal supplements an earlier proposal, thus no license fees are enclosed.

Duke Power believes that sufficient information has been submitted and discussions between our respective staffs have been sufficient to assure prompt, positive technical closure of this issue to support the scheduled August 22 entry into Mode 4 (Hot Shutdown), however, please feel free to contact us if you require any additional information.

Very truly yours, l

A u-Hal B. Tucker JBD/57/jgm Attachment

Mr. Harold R. Denton, Director August 5, 1986 Page 3 xc: w/ attachment Dr. J. Nelson Grace Mr. Dayne Brown, Chief Regional Administrator Radiation Protection Branch U.S. Nuclear Regulatory Commission Division of Facility Services Region II Dept. of Human Resources 101 Marietta Street, NW, Suite 2900 P.O. Box 12200 Atlanta, Georgia 30323 Raleigh, N.C.

27605 Mr. W.T. Orders Mr. Darl Hood, Project Manager NRC Resident Inspector Division of Licensing McGuire Nuclear Station Office of NRC Washington, D.C.