Requests Addl Info Re Response to IE Bulletin 85-003, Motor-Operated Valve Common Mode Failures During Plant Transients Due to Improper Switch Setting within 1 Month of Ltr Receipt
ML20212B523
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 08/01/1986
From: Norelius C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Dolan J
AMERICAN ELECTRIC POWER SERVICE CORP., INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
References
IEB-85-003, IEB-85-3, NUDOCS 8608070083
Download: ML20212B523 (2)


Text

(

  1. 1Mb AUG 01 1986 Docket No. 50-315 Docket No. 50-316 American Electric Power Service Corporation Indiana and Michigan Electric Company ATTN: Mr. John E. Dolan Vice Chairman Engineering and Construction 1 Riverside Plaza Columbus, OH 432i6 Gentlemen:

The preliminary review of your initial response to IE Bulletin 85-03

" Motor-0perated Valve Common Mode Failures During Plant Transients Due To Improper Switch Settings" indicates that it does not contain an adequate description of the program to assure valve operability as requested by Action Item e of the Bulletin. The program description in your response is little more than a paraphrase of the Bulletin's requirements. Additional information is requested within one month of receipt of this letter.

Responses may be submitted as specified in IE Bulletin 85-03, page 6, i.e.:

"The written reports shall be submitted to the appropriate Regional Administrator under oath or affirmation under provisions of Section 182a, Atomic Energy Act of 1954, as amended. Also, the original copy of the cover letters and a copy of the report shall be transmitted to the U.S. Nuclear Regulatory Commission Document Control Desk, Washington, DC 20555 for reproduction and distribution."

Questions addressing this issue may be forwarded to Richard J. Kiessel, IE (301)'492-8119.

Sincerely,

" Original 5fened by C. E. Norelius" Charles E. Norelius, Director Division of Reactor Projects See Attached Distribution