Forwards Exercise Rept for 860618 Exercise of Offsite Radiological Emergency Preparedness Plans.No Deficiencies Noted.Areas Requiring Corrective Action Noted in Rept.Plans Adequate
ML20212B261
Person / Time
Site: North Anna  Dominion icon.png
Issue date: 12/16/1986
From: Krimm R
Federal Emergency Management Agency
To: Jordan E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
Shared Package
ML20212B267 List:
References
NUDOCS 8612290209
Download: ML20212B261 (1)


Text

~

\ .

[< D g Federal Emergency Management Agency k

& Washington, D.C. 20472 DEC I 61986 MEMORANDUM FOR: Edward L. Jordan Director Division of Emergency Preparedness and Engineering Response Office of Inspection and Enforcement U. S. Nuclear Regulatory Camission FBOM: R urtti' Assistant Associate Director Office of Natural and Technological Hazards SUBJECI: Exercise Report for the June 18, 1986, Exercise of Offsite Radiological Emergency Preparedness Plans for the North Anna Power Station Attached is a copy of the exercise report for the June 18, 1986, exercise of the offsite radiological emergency preparedness plans for the North Anna Power Station. 'Ihis exercise report was prepared by the Region III staff of the Federal Emergency Management Agency.

There were no deficiencies identified during this exercise. However, there are several areas requiring corrective actions and several areas recomnended for improvennnt. A draft copy of the exercise report was provided to the Comnonwealth of Virginia for review and comment. Based on their review, a schedule of corrective actions is included in this final exercise report.

Therefore, the offsite radiological emergency plans and preparedness remain adequate to provide reasonable assurance that appropriate measures can be taken offsite to protect the health and safety of the public in the event of an accident at the North Anna Power Station, and the 44 CFR 350 approval granted on February 23, 1983, will remain in effect.

If you should have any questions, please contact Robert S. Wilkerson, Chief, Technological Hazards Division, at 646-2860.

Attachments 8612290209 8(-1216 PDR ADOCK 05000338 y Q t