F December 19, 1986 Docket No. 50-317 MEMORANDUM FOR:
Ashok C. Thadani, Director PWR Project Directorate #8 Division of PWR Licensing-B FROM:
Patrick M. Sears, Project Manager PWR Project Directorate #8 Division of PWR Licensing-B N
SUBJECT:
SUMMARY
OF MEETING HELD WITH BALTIMORE GAS & ELECTRIC COMPANY CONCERNING INDICATIONS IN CALVERT CLIFFS UNIT 1 MAIN STEAM LINE The meeting was held on December 10, 1986, 10:00 AM at the Air Rights Build' ig in Bethesda, Maryland.
The attendees are listed in Enclosure 1.
Background
Calvert Cliffs Unit 1 is down for refueling.
It is scheduled to start up again approximately December 24, 1986.
l During an ultrasonic inspection at Calvert Cliffs Unit 1 of a field weld of the 34" diameter, 1" wall main steam line, an indication was found.
That indication showed a " wide, 24" long circumferential wall thinning,
" to the centerline of the weld downstream of the field weld.
The wall thickness at the thinning was approximately.86".
Minimum code thickness is.95".
The indication was radiographed and that radiograph was compared to the radiograph made at the time of construction.
The radiographs were similar and this led BG&E personnel to conclude that the pipe wall thinning had been there since construction and was not the result of material erosion.
Using the above indications, BG&E personnel performed calculations to ascertain whether the pipe would still be within code limits.
The purpose of this meeting was to provide BG&E personnel an opportunity to present their calculations to the staff.
Lisa Decker, BG&E engineer responsible for the ultrasonic and radiographic inspections, outlined what BG&E had done.
Some discussion of the accuracy l
of the measurements ensued.
Michael Gahan, BG&E engineer responsible for I
calculations which were intended to show that the pipe thinning posed no safety problem, made a presentation.
Those calculations were to show that the pipe was slightly outside of code allowables when considering hoop stresses, I
and well within code allowables when considering longitudinal stresses.
Staff personnel asked BG&E personnel what their next planned step was going to be on this issue and BG&E personnel replied that a licensee event report (LER) was contemplated.
8612240282 861219 PDR
/, DOCK 05000317 P
ppg
,. Further discussions ensued centering on various codes in use and whether BG&E should stay with the use of B 31.1, 1969 Power Piping, and B 31.7, 1969 Nuclear Power Piping (as per FSAR) or to use other codes which might be more appropriate.
The meeting adjourned with a statement that the staff would caucus and would comment on BG&E's plan to report on this issue in an LER.
BG&E subsequently advised the staff.by telecon December 11, 1986 that a submittal would be made on or about December 15, 1986 covering their calculations, requesting a relief from the code requirements for a period of their new fuel cycle, and containing a proposal for remedial action.
.Ortsnal signed Dr Patrick M. Sears, Project Manager PWR Project Directorate #8 Division of PWR Licensing-B
Enclosure:
List of Attendees cc w/ enclosure:
See next page
. efD f
PBD#84 D#8 PBD#8 P
er PSears;cf Atha ni 12/ 4 /86 12/(Co/86 12// /86 4
i I
.,..s
- -..-.. a ;
2
+
x+w 2
-=~=w-r v.,
e MEETING
SUMMARY
DISTRIBUTION PWR PROJECT DIRECTORATE #8 Docket File NRC PDR L PDR PBD#8 Rdg DJaffe PKreutzer OELD EJordan BGrimes ACRS-10 NRC Participants P5 ears MHartzman EMurphy CYCheng LBMarsh RJWright AThadani l
l l
^
4 Mr. J. A. Tiernan Baltimore Gas & Electric Company Calvert Cliffs Nuclear Power Plant cc:
Mr. William T. Bowen, President Regional Administrator, Region I Calvert County Board of U.S. Nuclear Regulatory Commission Commissioners Office of Executive Director Prince Frederick, Maryland 20768 for Operations 631 Park Avenue D. A. Brune, Esq.
King of Prussia, Pennysivania 19406 General Counsel Baltimore Gas and Electric Company P. O. Box 1475 Baltimore, Maryland 21203 Jay E. Silberg Shaw, Pittnan, Potts and Trowbridge 2300 N Street, N.W.
Washington, DC 20037 Mr. M. E. Bowman, General Supervisor Technical Services Engineering Calvert Cliffs Nuclear Power Plant MD Rts 2 & 4, P. O. Box 1535 Lusby, Maryland 20657-0073 Resident Inspector c/o U.S. Nuclear Regulatory Commission P. O. Box 437 Lusby, Maryland 20657-0073 Bechtel Power Corporation ATTN: Mr. D. E. Stewart Calvert Cliffs Project Engineer 15740 Shady Grove Road Gaithersburg, Maryland 20760 Combustion Engineering, Inc.
ATTN: Mr. W. R. Horlacher, III Project Manager P. O. Box 500 1000 Prospect Hill Road Windsor, Connecticut 06095-0500 Department of Natural Resources Energy Administration, Power Plant Siting Program ATTN: Mr. T. Magette Tawes State Office Building Annapolis, Maryland 21204
2 v.
-r, x -: x 2 _
.e......-..w._
_ _ _.... _.. ~ _ _... _
O LIST OF ATTENDEES FOR MEETING HELD WITH BALTIMORE GAS & ELECTRIC COMPANY DECEMBER 10, 1986 NAME AFFILIATION TELEPHONE NUMBER Patrick Sears NRC/PWR-8/PBD#8 492-8006 Mark Hartzman NRC/PWR-B/EB 492-9429 William C. Holston BG&E-Senior Eng.-Mech. Design 260-4466 Alan Thornton BG&E-Gen. Sper. Plant & Proj.
260-4724 Engineer Michael J. Gahan, III BG&E Senior Engineer SSEU 260-4416 Lisa Decker BG&E Eng. Perf. Eng.
260-4802 Emmett Murphy NRC/0 RAS 492-8999 C. Y. Cheng NRC/PBEB 492-7614 L. B. Marsh NRC/PBEB 492-7955 R. J. Wright NRC/PBEB 492-7622 T. L. Sydnor BG&E/Prin. Eng. Secondary Sys.
260-4743 J. H. Pence, Jr.
BG&E Senior Eng.
787-5510 A. Thadani NRC/PWR-8/PBD#8 492-4553 l
l l
r