ML20211Q959
| ML20211Q959 | |
| Person / Time | |
|---|---|
| Site: | Wolf Creek |
| Issue date: | 07/21/1986 |
| From: | Gagliardo J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | Koester G KANSAS GAS & ELECTRIC CO. |
| References | |
| NUDOCS 8607280069 | |
| Download: ML20211Q959 (4) | |
See also: IR 05000482/1986012
Text
r
JUL 2 I 1986
'
,
In Reply Refer To:
Docket:
STN 50-482/86-12
Kansas Gas and Electric Company
ATTN: Glenn L. Koester
Vice President - Nuclear
P. O. Box 208
Wichita, Kansas 67201
Gentlemen:
This refers to the inspection conducted by Mr. James A. F. Kelly of this office
during the period May 5-9, 1986, of activities authorized by NRC Operating
License NPF-42, for Wolf Creek- Generating Station, and to the discussion of our
findings with Mr. F. T. Rhodes, and other members of your staff at the
conclusion of the inspection.
Areas examined during the inspection included the Physical Security Plan and
implementing procedures, management effectiveness, security organization
management, security program audit and records and reports.
Within these areas
the inspection consisted of selective examination of procedures and
representative records, interviews with personnel, and observation by the
inspector. The inspection findings are documented in the enclosed inspection
report.
During this inspection, it was found that certain of your activities were in
violation of NRC requirements.
Paragraphs 2 ar,d 3 of the enclosed inspection
report provide details of the apparent violation which has the potential for
escalated enforcement and will be the subject of separate correspondence.
As
discussed in the telephone conversation between Mr. Ramon Hall of this office
and you on July 18, 1986, no enforcement conference will be held to discuss
this matter.
However, after reviewing this report if you choose to have an
enforcement conference with us, plea,e contact Mr. Richard L. Bangart
(817 860-8248) of this office, and we will arrange to meet with you at the
earliest opportunity.
We have also examined actions you have taken with regard to previously
identified inspection findings.
The status of these items is identified in
paragraph 2 of the enclosed report.
The material enclosed herewith contains Safeguards Information as defined 'sy
10 CFR 73.21 and its disclosure to unauthorized individuals is prohibited by
Section 147 of the Atomic Energy Act of 1954, as amended.
Therefore, the
material, with the exception of the report cover page which is an inspection
summary, will not be placed in the Public Document Room.
!EP&SPS
E h
D:0
Ci
SN
C:RP
M
A0
tb
E0
AFKelly/lw
,
hndell
RLB3 g'arth0RHunter JEGag i rdo
Emerson DAPowers
M{/4/86
7 //o /86
/
Ih g/86
t,/p/86
$/p/86 F9 / f
/
/86
') /g
/
i
ENCLOSl!RE 00NTAIn3
l
SAFEGUARDS INFORMATION.
g
I
h72gDOhK
UPON SEPARATION THIS
O 482
O
PAGE IS DECONTROILED.
A
r -
.o
.
.
Kansas Gas and Electric Cortpany
-2-
Should you have any questions concerning this inspection, we will be pleased to
discuss them with you.
Sincerely,
"Driginal Signed bc>"
J. E. Gagliardo, Chief
Reactor Projects Branch
Enclosure:
Appendix - NRC Inspection Report
STN 50-482/86-12
cc w/ summary page only:
Kansas Gas and Electric Company
ATTN:
Otto Maynard, Manager
of Licensing
P. O.-Box 309 (Sharp Road)
Burlington, Kansas 66839
Forrest Rhodes, Plant Superintendent
Wolf Creek Generating Station
P. O. Box 309
,
Burlington, Kansas
66839'
Kansas Radiation' Control. Program Director
bcc:
Copy of entire report maintained in RIV Security File and sent to:
G. McCorkle, NMSS
<
J. Gibson, SSPD/NRR
IE File
Resident Inspector (w/766)
R.-Martin
-Security Inspector
Chief, EPSPS
D. Powers, E0
M. Emerson, A0
bcc:
RIV - Letter and Inspection Summary only w/766:
MIS
RPB
D. Weiss, LFMB (AR-2015)
Section Chief (RPSB)
RIV File
RSTS Operator
R&SPB
cc:
RIV - Letter and Inspection Summary only w/out 766:
J MB - IE04
R. L. Bangart, DRS&S
Myron Karman, ELD, MNBB
l
J. Harrison, RIII
ENCLOSURE CONTAINS
E. H. Johnson, DRS&P
SAFEGUARDS IMPURMATIW.
'
UPON SEPARATION THIS
i
PAGE IS DECONTROLLED.
l
i
'
'
- d
o
..
,.
~ ,
- - + ,
a.,~.-~
~n..,
.w.,-....,__._s,._,_.
. o
0
-
.
JUL l71900
In Reply Refer To:
Docket:
STN 50-482/86-12
Kansas Gas and Electric Company
ATTN:
Glenn L. Koester
Vice President - Nuclear
P. O. Box 208
Wichita, Kansas 67201
Gentlemen:
This refers to the inspection conducted by Mr. James A. F. Kelly of this office
during the period May 5-9, 1986, of activities authorized by NRC Operating
License NPF-42, for Wolf Creek Generating Station, and to the discussion of our
findings with Mr. F. T. Rhodes, and other members of your staff at the
conclusion of the inspection.
Areas examined during the inspection included the Physical Security Plan and
implementing procedures, management effectiveness, security organization
management, security program audit and records and reports. Within these areas
the inspection consisted of selective examination of procedures and
representative records, interviews with personnel, and observation by the
inspector.
The inspection findings are documented in the enclosed inspection
report.
During this inspection, it was found that certain of your activities were in
violation of NRC requirements.
Paragraphs 2 and 3 of the enclosed inspection
report provide details of the apparent violation.
As discussed in the July 11,
.
1986, telephone conversation between Mr. Richard L. Bangart of this office and
!
you, we have scheduled an enforcement conference in our office on July 28,
1986, at 1 p.m. to discuss this apparent violation, the reasons for occurrence,
l
and your corrective actions.
We will also discuss any enforcement options if
appropriate.
We have also examined actions you have taken with regard to previously
identified inspection findings.
The status of these items is identified in
,
I
paragraph 2 of the enclosed report.
The material enclosed herewith contains Safeguards Information as defined by
10 CFR 73.21 and its disclosure to unauthorized individuals is prohibited by
Section 147 of the Atomic Energy Act of 1954, as amended.
Therefore, the
i
!
material, with the exception of the report cover page which is an inspection
summary, will not be placed in the Public Document Room.
!
a
~~
g
hNdP&SPS
hEh5
D:0t,%S
Ci hS%
C:RP
A0
9
E0 k
\\ JAFKelly/lw
tandell
RLB%gart) DRHunter JEGag li rdo MEEmerson DAPowers
-
/g/86
,/g/86
[(,/p /86
i/ /86
') /g
8
/ /4 /86
7//o /86
f
ENCLOSLEE 03TAINS
SAFEGUARDS INFORMATION.
/,g
UPON SEPARATION THIS
/
..
,
.
..
Kansas Gas and Electric Company
-2-
Should you have any questions concerning this inspection, we will be pleased to
discuss them with you.
Sincerely,
Ori;inal Signed b e"
J. E. Gagliardo,-Chief
Reactor Projects Branch
Enclosure:
Appendix - NRC Inspection Report
STN 50-482/86-12
cc w/ summary page only:
Kansas Gas and Electric Company
ATTN:
Otto Maynard, Manager
of Licensing
P. O. Box 309 (Sharp Road)
Burlington, Kansas 66839
Forrest Rhodes, Plant Superintendent
Wolf Creek Generating Station
P. O. Box 309
Burlington, Kansas
66839
Kansas Radiation Control Program Director
bcc:
Copy of entire report maintained in RIV Security File and sent to:
G. McCorkle, NMSS
J. Gibson, SSPD/NRR
IE File
Resident Inspector (w/766)
R. Martin
Security Inspector
Chief, EPSPS
D. Powers, E0
M. Emerson, A0
bec:
RIV - Letter and Inspection Summary only w/766:
MIS
RPB
D. Weiss, LFMB (AR-2015)
Section Chief (RPSB)
RIV File
RSTS Operator
R&SPB
bcc:
RIV - Letter and Inspection Summary only w/out 766:
DMB - IE04
R. L. Bangart, DRS&S
Myron Karman, ELD, MNBB
J. Harrison, RIII
ENCLOSiRE CONTAINS
E. H. Johnson, DRS&P
SAFEGUMDS INMWATICE.
UPON SEPARATION THIS
PAGE IS DECONTROLLED.