Text

,-

@rewaums Consumers Power AINN5 PRBERE55 General offices: 1945 West Parnall Road, Jackson, MI 49201 + (517) 788-0550 February 24, 1987 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-155 - LICENSE DPR BIG ROCK POINT PLANT -

SHIPPING CASK DEFECT REPORT PER 10 CFR 71.95 During decontamination of a chem-nuclear system shipping cask prior to shipment, cracks were discovered in the cask bottom plate weld. This event has been determined to be reportable in accordance 10 CFR 71.95. The attached report provides the required 30-day written report.

The Nuclear Regulatory Commission Office of Nuclear Material Safety and Safeguards, Region III, and Senior Resident Inspector have previously been informed of this event.

m Ralpa R Frisch Senior Licensing Analyst CC Administrator, Region III, NRC NRC Resident Inspector - Big Rock Point Plant Director, NMSS Attachment G70303h93870224CK 05000155 I

PDR A

PDR I

l 9

OCO287-0051A-NLO2

.. _ _ _,. _ _ _ - _.. _, _ _. - -