ML20211Q321

From kanterella
Jump to navigation Jump to search
BWR (Deactivated) Annual Rept 22
ML20211Q321
Person / Time
Site: Vallecitos Nuclear Center
Issue date: 12/31/1986
From: Cunningham G
GENERAL ELECTRIC CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
22, NUDOCS 8703030064
Download: ML20211Q321 (5)


Text

. _ _ - _ -.

VALLECITOS BOILING WATER REACTOR (DEACTIVATED)

ANNUAL REPORT N0. 22 LICENSE DPR-1 l

DOCKET 50-18 NUCLEAR SYSTEMS TECHNOLOGIES OPERATION e GENERAL ELECTRIC COMPANY VALLECITOS NUCLEAR CENTER, PLEASANTON, CALIFORNIA 94566 kD0 SDO K ob

\\\\

a p

.s

'VALLECITOS BOILING WATER REACTOR (DEACTIVATED)

ANNUAL REPORT NO. 22 The status of the Vallecitos Boiling Water Reactor (VBWR) during the calendar year of 1986 is described in this twenty-second report of the deactivated facility in conformance with License DPR-1, Docket 50-18, Amendment-19, Paragraph 5.d.2.

I.

SUMMARY

The facility remained essentially in a static condition as described in Annual Report No. 21.

Entry into the containment building was made for routine radiation surveys and for a check of general conditions throughout the building to verify the unchanged condition of the facility. The reactor vessel water level vas monitored and remained essentially constant.

II.

STATUS OF Ti1E FACILITY A.

Containment Buildinn No changes were made during the report period.

B.

General Systems No changes were made during the report period.

III.

PERIODIC INSPECTIONS I

Inspections of the facility were continued on a routine basis.

The annual air samples and radiation and contamination surveys of the containment. building are given in Table 1 of this report. The levels shown are representative and are not necessarily maximums.

Surveys in several areas have been discontinued as they were no longer providing useful data this long after deactivation and, thus, continued monitoring is not consistent with ALARA.

IV.

RADIATION AND CONTAMINATION Radiation and contamination surveys of the facility indicate the levels in all cases were well below the limits for any safety concern.

1

t.

VBWR Annual Raport No. 22 V.

ORGANIZATION There were no' changes in organization.

VI.

CONCLUSION The deactivated Vallecitos Boiling Water Reactor continues to be maintained in a safe condition, commensurate with its shut down status. The methods of inspection and control of safety-related items ensure maximum protection for the public and the General Electric Company.

GENERAL ELECTRIC COMPANY Irradiatio rocessing Operation Q/

By G. W. Titus, Manage ~r-Reactor Operations & Support Services I-1 i

i-r 2

VBWR Annual Rsport No. 22 TABLE 1.

Radiation and Contamination Report Contamination Levels Radiation Surface Smears Airborne Levels Beta-Gamma **

Beta-Gamma (mR/h Gamma)

(com/100 cm2 x los)

(uci/cc x 10-10)

Reactor Enclosure 12/85 12/86 12/85 12/86 12/85 12/86 Main Floor - General Field

<1

<1 1.2 1.2 0.069*

0.043*

1.

Top of Missile Shield, Field

<1

<1 0.6 2.

Top of Spent Fuel Pit Cover

<1

<1 0.3 0.5 3.

Pit (down 3 ft.)

1.0

<1 9.0 Reactor Basement 1.

Upper Level, Field 15 10 2.

Bottom Wall, Ladder 15 2.5 3.

East Ladder, Bottom 10 6

4.0 1.6 0.11*

0.047 4.

West Ladder, Bottom 25 20 0.6 4.8 5.

Between Recirculation Pumps 30 15 N/A 3.1 (2 ft. off deck) 6.

Downcomers Behind Reactor 25 15/30 0.2 Shield 7.

Main Steam Line 5

18/25 0.5 Enclosure Stack - Outside Surface

<1

<1

<0.1 Main Valve Pit Lines and Valves

<1

<1

<0.1 N/A indicates readings not taken or not analyzed.

  • 24-hour decay.
    • For conversion to dpm, assume an instrument efficiency of 20%.

E01E: Radiation levels, surface smears, and air samples will vary from survey to survey as they are taken in general areas rather than at specific locations.

l 3

e GENERAL $ ELECTRIC NUCLEAR ENERGY BUSINESS OPERATIONS GENERAL ELECTRIC COMPANY e VALLECITOS NUCLEAR CENTER e PLEASANTON, CAUFORNIA 94566 February 23, 1987 U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Attention:

Document Control Desk

Reference:

License DPR-1, Docket 50-18 Gentlemen:

Enclosed are three signed copies of Annual Report No. 22 for the Vallecitos Boiling Water Reactor (deactivated).

Sincerely, Y {.

G. E. Cunningham Senior Licensing Engineer (415) 862-4330

/ca Enclosures t

iI