ML20211P191

From kanterella
Jump to navigation Jump to search
Forwards Safety Evaluation Re 860121 Response to PTS Rule, Per 10CFR50.61.Matl Properties of Reactor Vessel Beltline Matls,Projected Fluence at Inner Surface of Reactor Vessel for end-of-life of Plant & Calculated RT PTS Acceptable
ML20211P191
Person / Time
Site: Callaway Ameren icon.png
Issue date: 12/15/1986
From: Oconnor P
Office of Nuclear Reactor Regulation
To: Schnell D
UNION ELECTRIC CO.
Shared Package
ML20211P196 List:
References
REF-GTECI-A-49, REF-GTECI-RV, TASK-A-49, TASK-OR NUDOCS 8612190002
Download: ML20211P191 (2)


Text

w Docket No.: 50-483 Mr. D. F. Schnell 15 DEC 1986 Vice' President - Nuclear Union Electric Company Post Office Box 149 St. Louis, Missouri 63166

Dear Mr. Schnell:

Subject:

Projected Values of Material Properties for Fracture Toughness Requirements for Protection Against Pressurized Thermal Shock Events We have reviewed your letter dated January 21, 1986 which was submitted in re-sponse to the Pressurized Thermal Shock (PTS) Rule,10 CFR 50.61, for the Callaway Plant. We have found the material properties of reactor vessel belt-line materials, the projected fluence at the inner surface of the reactor vessel for the end of life of the plant, and the calculated RT for the end isbblowthe P

of life of the plant to be acceptable.

The calculated RT screening criteria of 270 F at 32 EFPY which is beyond thgThxpiration date of the license and, therefore, meets the requirements of the PTS Rule.

The PTS Rule requires that the projected assessment of the RT must be up-datedwheneverchangesincoreloadings,surveillancemeasurebtsorother information (including changes in capacity factor) indicate a significant change in the projected values. This ensures that the licensees will track the accumulated fluence for the limiting beltline materials throughout the life of the plant to verify that their assumptions remain valid.

In this regard we request that you submit a re-evaluation of the RT and c;mparison with the predicted value in any future Pressure-Temperature sbbmittals which p

are submitted as required by 10 CFR 50, Appendix G.

Our associated Safety Evaluation is enclosed.

Sincerely, Paul W. O'Connor, Project Manager PWR Project Directorate #4 Division of PWR Licensing-A

Enclosure:

As stated cc w/ enclosure: See next page Distribution:

Docket Filej M0uncan JPartlow NRC PDR P0'Connor BGrimes Local PDR BJYoungblood Edordan PRC System OGC-Bethesda NThompson PWR#4 rdg ACPS (101

$b k

PWR#4/DPWR-A P,WPhPWR-A PWR1Iy 4R-A s

P0 'Connor/mac MDtfncan BJY6u hjood 12/ H /86 12// 1./86 12/4/86 8612190002 861215 PDR ADOCK 0500 3

P

r

~

  • \\

4 Mr. D. F. Schnell Callaway Plant i

Union Electric Company Unit No. 1 CC:

Mr. Nicholas A. Petrick Lewis C. Green, Esq.

Executive Director - SNUPPS Green, Hennings & Henry 5 Choke Cherry Road Attorney for Joint Intervenors Rockville, Maryland 20850 314 N. Broadway, Suite 1830 St. Louis, Missouri 65251 Gerald Charnoff, Esq.

Thomas A. Baxter, Esq.

Ms. Marjorie Reilly Shaw, Pittman, Potts & Trowbridge Energy Chairman of the League of 2300 N Street, N. W.

Women Voters of Univ. City, M0 Washington, D. C.

20037 7065 Pershing Avenue University City, Missouri 63130 Mr. J. E. Birk Assistant to the General Counsel Mr. Donald Bollinger, Member Union Electric Company Missourians for Safe Energy Post Office Box 149 6267 Delmar Boulevard St. Louis, Missouri 63166 University City, Missouri 63130 U. S. Nuclear Regulatory Commission Mr. Dan I. Bolef, President m N Resident Inspectors Office Kay Drey, Representative RR#1 Board of Directors Coalition Steedman, Missouri 65077 for the Environment St. Louis Region Mr. Donald W. Capone, Manager 6267 Delmar Boulevard Nuclear Engineering University City, Missouri 63130 Union Electric Company Post Office Box 149 St. Louis, Missouri 63166 Chris R. Rogers, P.E.

Manager - Electric Department 301 W. High Post Office Box 360 Jefferson City, Missouri 65102 i

Regional Administrator U. S. NRC, Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Mr. Ronald A. Kucera, Deputy Director Department of Natural Resources P. O. Box 176 Jefferson City, Missouri 65102 i

Mr. Glenn L. Koester Vice President - Nuclear Kansas Gas and Electric Company j

201 North Market Street l

Post Office Box 208 l

Wichita, Kansas 67201

_ _ _ _